SearcharxivSearch

arXiv subjects

Taylor Aralis

Publications and source records attributed to Taylor Aralis.

9 recordsLinked to original sources

Performance of a SuperCDMS HVeV Detector with Sub-eV Energy Resolution and Single Charge-sensitivity

We present a detailed characterization of a new generation of athermal-phonon single-charge sensitive Si HVeV detectors, the best of which achieved 589~meV~$\pm$~5~meV baseline resolution. Our sub-eV energy resolution enables precise measurements of single-photon events and reveal consistent energy losses of 0.92~eV~$\pm$~0.02~eV per charge excitation across two facilities. We demonstrate that the noise for these detectors is well described using a standard Transition Edge Sensor noise model. We also measure a nominal phonon collection efficiency of 45\%~$\pm$~3\%~(stat.)~$\pm$~6\%~(syst.) in the best performing device, establishing these detectors as the most efficient athermal phonon detectors to date, limited only by intrinsic limitations of quasiparticle generation.

physics.ins-det

Noise Modeling and Calibration of a Two-Stage Cryogenic Charge Amplifier for the SPLENDOR Experiment

The SPLENDOR Collaboration studies novel narrow-gap semiconductors and engineered a substrate agnostic detector platform to achieve $\mathcal{O}$(meV) energy sensitivity designed for low mass dark matter searches. This was achieved using low-capacitance and low-noise commercial CryoHEMTs in a split-stage topology integrated throughout a dilution refrigerator. Designed with a source-follower HEMT at the base temperature stage and a voltage amplifier at 4\,K, this amplifier has input-limited voltage noise of 10 $\text{nV}/\sqrt{\text{Hz}}$ and current noise of 100 $\text{aA}/\sqrt{\text{Hz}}$ at 1kHz. In agreement with this noise level and a photon calibration, this amplifier has a $\text{19} \pm \text{4} $ electron resolution.

physics.ins-det

Development Status of the KIPM Detector Consortium

A Kinetic Inductance Phonon-Mediated Detector is a calorimeter that uses kinetic inductance detectors to read out phonon signals from the device substrate. We have established a consortium comprising university and national lab groups dedicated to advancing the state of the art in these detectors, with the ultimate goal of designing a detector sub-eV threshold on energy deposited in the substrate, enabling searches for both light dark matter and low-energy neutrino interactions. This consortium brings together experts in kinetic inductance detector design, phonon and quasiparticle dynamics, and noise modeling, along with specialized fabrication facilities, test platforms, and unique calibration capabilities. Recently, our consortium has demonstrated a resolution on energy absorbed by the sensor of 2.1 eV, the current record for such devices. The current focus of the consortium is modeling and improving the phonon collection efficiency and implementing low-$\boldsymbol{T_c}$ superconductors, both of which serve to improve the overall energy resolution and threshold of the detectors.

physics.ins-det

Significant noise improvement in a Kinetic Inductance Phonon-Mediated detector by use of a wideband parametric amplifier

Microwave Kinetic Inductance Detectors (MKIDs) have been demonstrated as capable phonon sensors when coupled to crystalline substrates, and have been proposed as detectors for next-generation rare-event searches such as for the direct detection of dark matter. These Kinetic Inductance Phonon Mediated (KIPM) detector designs, favoring large superconducting absorber volumes and high readout powers, are oftentimes limited in their sensitivity by low temperature amplifier noise introduced in the signal readout chain. We report here an effort to couple a wideband Kinetic Inductance Travelling Wave Parametric Amplifier (KI-TWPA), operated near the Standard Quantum Limit of minimal added amplifier noise, to sensors spanning a 70 MHz bandwidth at 3.5 GHz. This results in a ~5x improvement in the inferred detector energy resolution in the best sensor and highlights the potential of constructing O(100) meV resolving phonon-mediated particle detectors. We detail limitations introduced by lossy passive components, degraded RF responsivity, and microphysical noise sources like two-level systems (TLS), in achieving ultimate quantum-limited system noise levels.

physics.ins-det

Performance of a Kinetic Inductance Phonon-Mediated Detector at the NEXUS Cryogenic Facility

Microcalorimeters that leverage microwave kinetic inductance detectors to read out phonon signals in the particle-absorbing target, referred to as kinetic inductance phonon-mediated (KIPM) detectors, offer an attractive detector architecture to probe dark matter (DM) down to the fermionic thermal relic mass limit. A prototype KIPM detector featuring a single aluminum resonator patterned onto a 1-gram silicon substrate was operated in the NEXUS low-background facility at Fermilab for characterization and evaluation of this detector architecture's efficacy for a dark matter search. An energy calibration was performed by exposing the bare substrate to a pulsed source of 470 nm photons, resulting in a baseline resolution on the energy absorbed by the phonon sensor of $2.1\pm0.2$ eV, a factor of two better than the current state-of-the-art, enabled by millisecond-scale quasiparticle lifetimes. However, due to the sub-percent phonon collection efficiency, the resolution on energy deposited in the substrate is limited to $\sigma_E=318 \pm 28$ eV. We further model the signal pulse shape as a function of device temperature to extract quasiparticle lifetimes, as well as the observed noise spectra, both of which impact the baseline resolution of the sensor.

physics.ins-det

Identifying drivers of energy resolution variation in multi-KID phonon-mediated detectors

Phonon-mediated particle detectors employing Kinetic Inductance Detectors (KIDs) on Silicon substrates have demonstrated both O(10) eV energy resolution and mm position resolution, making them strong candidates for instrumenting next generation rare-event experiments such as in looking for dark matter or in neutrino measurements. Previous work has demonstrated the performance of an 80-KID array on a Si wafer, however current energy resolution measurements show a 25x difference between otherwise identical KIDs on the same wafer - between 5 to 125 eV on energy absorbed by the KID. Here, we use a first principles approach and attempt to identify the drivers behind the resolution variation. In particular, we analyze a subset of 8 KIDs using the unique approach of pulsing neighboring KIDs to generate signals in the target. We tentatively identify differences in quality factor terms as the likely culprit for the observed variation.

physics.ins-det

A Search for Low-mass Dark Matter via Bremsstrahlung Radiation and the Migdal Effect in SuperCDMS

In this paper, we present a re-analysis of SuperCDMS data using a profile likelihood approach to search for sub-GeV dark matter particles (DM) through two inelastic scattering channels: bremsstrahlung radiation and the Migdal effect. By considering possible inelastic scattering channels, experimental sensitivity can be extended to DM masses that would otherwise be undetectable through the DM-nucleon elastic scattering channel, given the energy threshold of current experiments. We exclude DM masses down to $220~\textrm{MeV}/c^2$ at $2.7 \times 10^{-30}~\textrm{cm}^2$ via the bremsstrahlung channel. The Migdal channel search excludes DM masses down to $30~\textrm{MeV}/c^2$ at $5.0 \times 10^{-30}~\textrm{cm}^2$.

hep-ex

Performance of a phonon-mediated detector using KIDs optimized for sub-GeV dark matter

Detection of sub-GeV dark matter candidates requires sub-keV detector thresholds on deposited energy. We provide an update on a gram-scale phonon-mediated KID-based device that was designed for a dark matter search in this mass range at the Northwestern Experimental Underground Site. Currently, the device is demonstrating 6 eV resolution on the energy absorbed by the resonator. With some important assumptions, this translates to 20 eV baseline resolution on energy deposited in the substrate. We show that TLS noise dominates this energy resolution estimate. After modifying the design to mitigate TLS noise, we project 5 eV baseline resolution on energy deposited in the substrate (1.5 eV on energy absorbed by the resonator) for an amplifier-white-noise-dominated device. Finally, we present a clear path forward to sub-eV thresholds, which includes installation of a quantum-limited superconducting parametric amplifier and adjustments to the material makeup of our resonators.

physics.ins-det

Energy Loss Due to Defect Formation from $^{206}$Pb Recoils in SuperCDMS Germanium Detectors

The Super Cryogenic Dark Matter Search experiment (SuperCDMS) at the Soudan Underground Laboratory studied energy loss associated with Frenkel defect formation in germanium crystals at mK temperatures using in situ $^{210}$Pb sources. We examine the spectrum of $^{206}$Pb nuclear recoils near its expected 103 keV endpoint energy and determine an energy loss of $\left(6.08\pm0.18\right)$ %, which we attribute to defect formation. From this result and using TRIM simulations, we extract the first experimentally determined average displacement threshold energy of $\left(19.7^{+0.6}_{-0.5}\right)$ eV for germanium. This has implications for the analysis thresholds of future germanium-based dark matter searches.

physics.ins-det