Searcharxiv⌕ Search

arXiv subjects

Tej Varma Yenupuri

Publications and source records attributed to Tej Varma Yenupuri.

2 recordsLinked to original sources

Three-dimensional imaging of isolated membrane-protein complexes in vacuo with an X-ray laser

The prospect of imaging single biomolecules, viruses and cells with intense, ultrashort X-ray pulses has driven the development of X-ray free-electron lasers (XFELs). However, the weak scattering from small particles is easily swamped by background from residual gas, which has so far limited applications to strongly scattering targets such as viruses, cell organelles and cells. Here we report a three-dimensional (3D) reconstruction of an isolated 1-MDa membrane-protein complex, photosystem I (PS I), from single-particle diffraction data. PS I trimers were aerosolised by charge-reduction electrospray ionisation and injected into the European XFEL beam, with partial helium gas exchange reducing background scattering by 80%. From 32 788 diffraction patterns of single trimers in random orientations, we reconstructed the 3D electron density to a resolution of 3.8 nm, limited by the detector geometry. The disc-shaped density, about 22 nm across and 10 nm thick, matches the size of a PS I trimer in a detergent micelle and is consistent with the compaction predicted by molecular dynamics simulations of the complex in vacuo and observed in native mass spectrometry. These results show that membrane-protein complexes can be imaged in vacuo with X-ray lasers, an important step towards ultrafast diffractive imaging of single macromolecules.

physics.bio-ph↗

Helium-Electrospray: an improved sample delivery system for single-particle imaging with X-ray lasers

Imaging the structure and observing the dynamics of isolated proteins using single-particle X-ray diffractive imaging (SPI) is one of the potential applications of X-ray free-electron lasers (XFELs). Currently, SPI experiments on isolated proteins are limited by three factors: low signal strength, limited data and high background from gas scattering. The last two factors are largely due to the shortcomings of the aerosol sample delivery methods in use. Here we present our modified electrospray ionization (ESI) source, which we dubbed Helium-ESI (He-ESI). With it, we increased particle delivery into the interaction region by a factor of 10, for 26 nm-sized biological particles, and decreased the gas load in the interaction chamber corresponding to an 80% reduction in gas scattering when compared to the original ESI. These improvements will lead to a significant increase in the quality and quantity of SPI diffraction patterns in future experiments using He-ESI, resulting in higher-resolution structures.

physics.ins-det↗