Teresa Guallart-Naval

Publications and source records attributed to Teresa Guallart-Naval.

9 recordsLinked to original sources

A wearable, stretchable radio-frequency coil for extremity imaging in low-field MRI systems

Purpose: To develop a wearable, stretchable radio-frequency (RF) coil that conforms to the extremities and improves the filling factor in low-field MRI. Methods: A stretchable solenoid RF coil was fabricated by stitching a sinusoidally arranged Litz-wire conductor onto an elastic textile. The coil was compared with four rigid coils, including two routinely used designs and two prototypes designed to isolate the effects of conductor material and stretchability. Performance was characterized through quality-factor, loading-factor, transmit-efficiency, and image-based signal-to-noise ratio (SNR) measurements. Phantom and in-vivo knee experiments for one volunteer were performed using two portable MRI systems operating at 3.53 and 3.04 MHz. Results: The electrical performance of the selected Litz wire decreased with increasing frequency, becoming a slight disadvantage at 3.53 MHz. Nevertheless, the stretchable coil provided the highest phantom SNR in both systems, exceeding that of the best-performing rigid coil by approximately 8 % at 3.53 MHz and 20 % at 3.04 MHz. In vivo, its global SNR was 5 % lower than that of the best rigid coil at 3.53 MHz and 19 % higher at 3.04 MHz. Compared with the larger rigid coil required when knee positioning is constrained, the corresponding SNR improvements were approximately 18 % and 80 %. Conclusion: Anatomical conformity can compensate for the frequency-dependent electrical limitations of Litz wire in stretchable low-field RF coils. The proposed design provided SNR comparable to or greater than the best rigid designs while facilitating coil placement in subjects for whom smaller rigid coils may be impractical.

physics.med-ph↗

Qualitative and quantitative hard-tissue MRI with portable Halbach scanners

Purpose: To demonstrate the feasibility of performing in-vivo imaging and quantitative relaxation mapping of soft and hard tissues using a low-cost, portable MRI scanner, and to establish the methodological foundations for zero echo time (ZTE) imaging in systems affected by strong field inhomogeneities. Methods: A complete framework for artifact-free ZTE imaging at low field was developed, including: (i) RF pulse pre/counteremphasis calibration to minimize ring-down and electronics switching time; (ii) an extension of a recent single-point double-shot (SPDS) protocol for simultaneous B0 and B1 mapping; and (iii) a model-based reconstruction incorporating these field maps into the encoding matrix. ZTE imaging and variable flip angle (VFA) T1 mapping were performed on phantoms and in-vivo human knees and ankles, and benchmarked against standard RARE and STIR acquisitions. Results: The optimized PETRA sequence produced 3D images of knees and ankles within clinically compatible times (< 15 min), revealing hard tissues such as ligaments, tendons, cartilage, and bone that are invisible in spin-echo sequences. The extended SPDS method enabled accurate field mapping, while the VFA approach provided the first in-vivo T1 measurements of hard tissues at B0 < 0.1 T. Conclusions: The proposed framework broadens the range of pulse sequences feasible in portable low-field MRI and demonstrates the potential of ZTE for quantitative and structural imaging of musculoskeletal tissues in affordable Halbach-based systems.

physics.med-ph↗

Comment on electromagnetic noise cancellation in low-field MRI systems (arXiv:2509.05955v1, 2406.17804v3, 2210.06730v2, and related works)

In this Comment, we discuss recent approaches to electromagnetic interference (EMI) mitigation in low-field Magnetic Resonance Imaging (LF-MRI), as presented in arXiv preprints 2509.05955v1, 2406.17804v3, or 2210.06730v2. These and other works explore noise cancellation strategies based on external sensing coils for post-elimination of EMI. We argue that, under realistic conditions, such approaches lead to residual signal contamination that necessarily exceed that obtained with optimal hardware-based pre-elimination.

physics.med-ph↗

High-resolution ultra-low-field MRI with SNRAware denoising

Ultra-low-field (ULF, <0.1 T) magnetic resonance imaging (MRI) systems offer advantages in cost, portability, and accessibility, but their current utility is still limited by low signal-to-noise ratio (SNR). Deep learning (DL)-based denoising has emerged as a potential strategy to mitigate this limitation. In this work, we present a systematic evaluation of a high-performance DL denoising model trained using the SNRAware framework and applied to 88 mT and 72 mT data. Using a series of controlled experiments, we assessed model performance as a function of spatial resolution, coil impedance matching, readout bandwidth, input noise level, k-space undersampling, anatomy, image contrast, and scanner platform, and compared against analytical denoising algorithms. The model consistently increased the effective SNR of ULF acquisitions, enabling images with nominal spatial resolutions comparable to those commonly used in clinical 3 T protocols. Residual analyses indicated that the model predominantly removed stochastic noise while preserving underlying signal structure. At the same time, the results highlight some constraints: denoising performance remains dependent on the starting SNR of the acquisition, and training-domain mismatch influences behavior under certain artifact conditions. These findings suggest that DL-based denoising can significantly expand the practical capabilities of ULF MRI, while emphasizing potential benefits from hardware-software co-optimization and the need for rigorous clinical validation to determine the diagnostic value of denoised images.

physics.med-ph↗

Electromagnetic Noise Characterization and Suppression in Low-Field MRI Systems

Purpose: Low-field MRI systems operate at single MHz-range frequencies, where signal losses are primarily dominated by thermal noise from the radio-frequency (RF) receive coils. Achieving operation close to this limit is essential for maximizing imaging performance and signal-to-noise ratio (SNR). However, electromagnetic interference (EMI) from cabling, electronics, and patient loading often degrades system performance. Our goal is to develop and validate a practical protocol that guides users in identifying and suppressing electromagnetic noise in low-field MRI systems, enabling operation near the thermal noise limit. Methods: We present a systematic, stepwise methodology that includes diagnostic measurements, hardware isolation strategies, and good practices for cabling and shielding. Each step is validated with corresponding noise measurements under increasingly complex system configurations, both unloaded and with a human subject present. Results: Noise levels were monitored through the incremental assembly of a low-field MRI system, revealing key sources of EMI and quantifying their impact. Final configurations achieved noise within 1.5x the theoretical thermal bound with a subject in the scanner. Image reconstructions illustrate the direct relationship between system noise and image quality. Conclusion: The proposed protocol enables low-field MRI systems to operate close to fundamental noise limits in realistic conditions. The framework also provides actionable guidance for the integration of additional system components, such as gradient drivers and automatic tuning networks, without compromising SNR.

physics.med-ph↗

In-vivo imaging with a low-cost MRI scanner and cloud data processing in low-resource settings

Purpose: To demonstrate in-vivo imaging with a low-cost, low-field MRI scanner built and operated in Africa, and to show how systematic hardware and software improvements can mitigate the main operational limitations encountered in low-resource environments. Methods: A 46 mT Halbach scanner located at the Mbarara University of Science and Technology (Uganda) was upgraded through a complete reorganization of grounding and shielding, installation of new control electronics and open-source user-interface software. Noise performance was quantified using a standardized protocol and in-vivo brain images were acquired with three-dimensional RARE sequences. Distortion correction was implemented using cloud-based reconstructions incorporating magnetic field maps. Results: The revamped system reached noise levels routinely below three times the thermal limit and demonstrated stable operation over multi-day measurements. Three-dimensional T1- and T2-weighted brain images were successfully acquired and distortion-corrected with remote GPU-based reconstructions and near real-time visualization through the user interface. Conclusions: The results show that low-cost MRI systems can achieve clinically relevant image quality when electromagnetic noise and power-grid instabilities are properly addressed. This work highlights the feasibility of sustainable MRI development in low-resource settings and identifies stable power delivery and local capacity building as the key next steps toward clinical translation.

physics.med-ph↗

Subject grounding to reduce electromagnetic interference for MRI scanners operating in unshielded environments

Purpose. Portable low-field (< 0.1 T) MRI is increasingly used for point-of-care imaging, but electromagnetic interference (EMI) presents a significant challenge, especially in unshielded environments. EMI can degrade image quality and compromise diagnostic utility. This study investigates whether subject grounding can effectively reduce EMI and improve image quality, comparing different grounding strategies. Methods. Experiments were conducted using a 47 mT Halbach-based MRI scanner with a single receive channel. Reproducibility was evaluated at a second site using a 72 mT scanner with similar geometry. Turbo spin echo sequences were used to image the hand and brain. Subject grounding was implemented using conductive cloth sleeves or ECG electrodes, each connected between the subject's skin and scanner ground. Three EMI conditions were tested: ambient, added single-frequency EMI, and broadband EMI. Signal-to-noise ratios (SNR) were calculated under each configuration. Results. Subject grounding significantly reduced EMI in both hand and brain scans. In hand imaging, conductive sleeves reduced noise from 85x to 1.25x the 50-ohm noise floor. In brain imaging, grounding alone reduced noise from 55x to 25x baseline; when combined with arc RF shields, noise was further reduced to 1.2x baseline, even under added EMI. These results were reproducible across different scanners and locations. Conclusion. Subject grounding is a simple, effective, and reproducible strategy for mitigating EMI in portable low-field MRI. It is especially effective for hand imaging, while brain imaging benefits from additional RF shielding. The approach is robust under various EMI conditions and may complement other denoising techniques.

physics.med-ph↗

ezyMRI: How to build an MRI machine from scratch -- Experience from a four-day hackathon

Nuclear magnetic resonance instruments are becoming available to the do-it-yourself community. The challenges encountered in the endeavor to build a magnetic resonance imaging instrument from scratch were confronted in a four-day hackathon at Singapore University of Technology and Design in spring 2024. One day was devoted to educational lectures and three days to system construction and testing. Seventy young researchers from all parts of the world formed six teams focusing on magnet, gradient coil, RF coil, console, system integration, and design, which together produced a working MRI instrument in three days. The different steps, encountered challenges, and their solutions are reported.

physics.med-ph↗

Elliptical Halbach magnet and gradient modules for low-field portable MRI

Objective. To develop methods to design the complete magnetic system for a truly portable MRI scanner for neurological and musculoskeletal (MSK) applications, optimized for field homogeneity, field of view (FoV) and gradient performance compared to existing low-weight configurations. Approach. We explore optimal elliptic-bore Halbach configurations based on discrete arrays of permanent magnets. In this way, we seek to improve the field homogeneity and remove constraints to the extent of the gradient coils typical of Halbach magnets. Specifically, we have optimized a tightly-packed distribution of magnetic Nd$_2$Fe$_14$B cubes with differential evolution algorithms, and a second array of shimming magnets with interior point and differential evolution methods. We have also designed and constructed an elliptical set of gradient coils that extend over the whole magnet length, maximizing the distance between the lobe centers. These are optimized with a target field method minimizing a cost function that considers also heat dissipation. Main result. We have employed the new toolbox to build the main magnet and gradient modules for a portable MRI scanner designed for point-of-care and residential use. The elliptical Halbach bore has semi-axes of 10 & 14 cm and the magnet generates a field of 87 mT homogeneous down to 5,700 ppm (parts per million) in a 20 cm diameter FoV, it weighs 216 kg and has a width of 65 cm and a height of 72 cm. Gradient efficiencies go up to around 0.8 mT/m/A, for a maximum of 12 mT/m with in 0.5 ms with 15 A & 15 V amplifier. The distance between lobes is 28 cm, significantly increased with respect to other Halbach-based scanners. Heat dissipation is around 25 W at maximum power, and gradient deviations from linearity are below 20% in a 20 cm sphere.

physics.med-ph↗