SearcharxivSearch

arXiv subjects

Th. Udem

Publications and source records attributed to Th. Udem.

15 recordsLinked to original sources

Long-distance chronometric leveling with a portable optical clock

We have measured the geopotential difference between two locations separated by $457~\mathrm{km}$ by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The $^{87}$Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of $3918.1(2.6)\,\mathrm{m^2 \, s^{-2}}$ agrees with an independent geodetic determination of $3915.88(0.30)\,\mathrm{m^2 \, s^{-2}}$. The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of $27~\mathrm{cm}$ in height.

physics.atom-ph

The solar gravitational redshift from HARPS-LFC Moon spectra. A test of the General Theory of Relativity

The General Theory of Relativity predicts the redshift of spectral lines in the solar photosphere, as a consequence of the gravitational potential of the Sun. This effect can be measured from a solar disk-integrated flux spectrum of the Sun's reflected light on solar system bodies. The laser frequency comb (LFC) calibration system attached to the HARPS spectrograph offers the possibility to perform an accurate measurement of the solar gravitational redshift (GRS) by observing the Moon or other solar system bodies. We have analysed the line shift observed in Fe absorption lines from five high-quality HARPS-LFC spectra of the Moon. We select an initial sample of 326 photospheric Fe lines in the spectral range 476-585 nm and measure their line positions and equivalent widths (EWs). Accurate line shifts are derived from the wavelength position of the core of the lines compared with the laboratory wavelengths. We fit the observed spectral Fe lines using CO$^5$BOLD 3D synthetic profiles. Convective motions in the solar photosphere do not affect the line cores of Fe lines stronger than about $\sim 150$ mA. In our sample, only 15 FeI lines have EWs in the range $150 <$ EW(mA) $< 550$, providing a measurement of the solar GRS at $639\pm14$ ${\rm m\;s^{-1}}$, consistent with the expected theoretical value on Earth of $\sim 633.1$ ${\rm m\;s^{-1}}$. A final sample of about 97 weak Fe lines with EW $<180$ mA allows us to derive a mean global line shift of $638\pm6$ ${\rm m\;s^{-1}}$ in agreement with the theoretical solar GRS. These are the most accurate measurements of the solar GRS so far. Ultrastable spectrographs calibrated with the LFC over a larger spectral range, such as HARPS or ESPRESSO, together with a further improvement on the laboratory wavelengths, could provide a more robust measurement of the solar GRS and further tests for the 3D hydrodynamical models.

astro-ph.SR

A Frequency Comb calibrated Solar Atlas

The solar spectrum is a primary reference for the study of physical processes in stars and their variation during activity cycles. In Nov 2010 an experiment with a prototype of a Laser Frequency Comb (LFC) calibration system was performed with the HARPS spectrograph of the 3.6m ESO telescope at La Silla during which high signal-to-noise spectra of the Moon were obtained. We exploit those Echelle spectra to study the optical integrated solar spectrum . The DAOSPEC program is used to measure solar line positions through gaussian fitting in an automatic way. We first apply the LFC solar spectrum to characterize the CCDs of the HARPS spectrograph. The comparison of the LFC and Th-Ar calibrated spectra reveals S-type distortions on each order along the whole spectral range with an amplitude of +/-40 m/s. This confirms the pattern found by Wilken et al. (2010) on a single order and extends the detection of the distortions to the whole analyzed region revealing that the precise shape varies with wavelength. A new data reduction is implemented to deal with CCD pixel inequalities to obtain a wavelength corrected solar spectrum. By using this spectrum we provide a new LFC calibrated solar atlas with 400 line positions in the range of 476-530, and 175 lines in the 534-585 nm range. The new LFC atlas improves the accuracy of individual lines by a significant factor reaching a mean value of about 10 m/s. The LFC--based solar line wavelengths are essentially free of major instrumental effects and provide a reference for absolute solar line positions. We suggest that future LFC observations could be used to trace small radial velocity changes of the whole solar photospheric spectrum in connection with the solar cycle and for direct comparison with the predicted line positions of 3D radiative hydrodynamical models of the solar photosphere.

astro-ph.SR

Sub-milliKelvin spatial thermometry of a single Doppler cooled ion in a Paul trap

We report on observations of thermal motion of a single, Doppler-cooled ion along the axis of a linear radio-frequency quadrupole trap. We show that for a harmonic potential the thermal occupation of energy levels leads to Gaussian distribution of the ion's axial position. The dependence of the spatial thermal spread on the trap potential is used for precise calibration of our imaging system's point spread function and sub-milliKelvin thermometry. We employ this technique to investigate the laser detuning dependence of the Doppler temperature.

physics.atom-ph

Comment on "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions"

In an article "Missing Transverse-Doppler Effect in Time-Dilation Experiments with High-Speed Ions" by S. Devasia [arXiv:1003.2970v1], our recent Doppler shift experiments on fast ion beams are reanalyzed. Contrary to our analysis, Devasia concludes that our results provide an "indication of Lorentz violation". We argue that this conclusion is based on a fundamental misunderstanding of our experimental scheme and reiterate that our results are in excellent agreement with Special Relativity.

physics.atom-ph

Precision spectroscopy of the 3s-3p fine structure doublet in Mg+

We apply a recently demonstrated method for precision spectroscopy on strong transitions in trapped ions to measure both fine structure components of the 3s-3p transition in 24-Mg+ and 26-Mg+. We deduce absolute frequency reference data for transition frequencies, isotope shifts and fine structure splittings that are in particular useful for comparison with quasar absorption spectra, which test possible space-time variations of the fine structure constant. The measurement accuracy improves previous literature values, when existing, by more than two orders of magnitude.

physics.atom-ph

Testing the Stability of the Fine Structure Constant in the Laboratory

In this review we discuss the progress of the past decade in testing for a possible temporal variation of the fine structure constant $α$. Advances in atomic sample preparation, laser spectroscopy and optical frequency measurements led to rapid reduction of measurement uncertainties. Eventually laboratory tests became the most sensitive tool to detect a possible variation of $α$ at the present epoch. We explain the methods and technologies that helped make this possible.

quant-ph

Frequency Metrology on single trapped ions in the weak binding limit: The 3s1/2-3p3/2 transition in 24-Mg+

We demonstrate a method for precision spectroscopy on trapped ions in the limit of unresolved motional sidebands. By sympathetic cooling of a chain of crystallized ions we suppress adverse temperature variations induced by the spectroscopy laser that usually lead to a distorted line profle and obtain a Voigt profile with negligible distortions. We applied the method to measure the absolute frequency of the astrophysically relevant D2 transition in single 24-Mg+ ions and find 1072082934.33(16)MHz, a nearly 400fold improvement over previous results. Further, we find the excited state lifetime to be 3.84(10) ns.

physics.atom-ph

Sub-Hz line width diode lasers by stabilization to vibrationally and thermally compensated ULE Fabry-Perot cavities

We achieved a 0.5 Hz optical beat note line width with ~ 0.1 Hz/s frequency drift at 972 nm between two external cavity diode lasers independently stabilized to two vertically mounted Fabry-Perot (FP) reference cavities. Vertical FP reference cavities are suspended in mid-plane such that the influence of vertical vibrations to the mirror separation is significantly suppressed. This makes the setup virtually immune for vertical vibrations that are more difficult to isolate than the horizontal vibrations. To compensate for thermal drifts the FP spacers are made from Ultra-Low-Expansion (ULE) glass which possesses a zero linear expansion coefficient. A new design using Peltier elements in vacuum allows operation at an optimal temperature where the quadratic temperature expansion of the ULE could be eliminated as well. The measured linear drift of such ULE FP cavity of 63 mHz/s was due to material aging and the residual frequency fluctuations were less than 40 Hz during 16 hours of measurement. Some part of the temperature-caused drift is attributed to the thermal expansion of the mirror coatings. High-frequency thermal fluctuations that cause vibrations of the mirror surfaces limit the stability of a well designed reference cavity. By comparing two similar laser systems we obtain an Allan instability of 2*10-15 between 0.1 and 10 s averaging time, which is close to the theoretical thermal noise limit.

physics.optics

High-precision wavelength calibration of astronomical spectrographs with laser frequency combs

We describe a possible new technique for precise wavelength calibration of high-resolution astronomical spectrographs using femtosecond-pulsed mode-locked lasers controlled by stable oscillators such as atomic clocks. Such `frequency combs' provide a series of narrow modes which are uniformly spaced according to the laser's pulse repetition rate and whose absolute frequencies are known a priori with relative precision better than 10^{-12}. Simulations of frequency comb spectra show that the photon-limited wavelength calibration precision achievable with existing echelle spectrographs should be ~1 cm/s when integrated over a 4000A range. Moreover, comb spectra may be used to accurately characterise distortions of the wavelength scale introduced by the spectrograph and detector system. The simulations show that frequency combs with pulse repetition rates of 5-30GHz are required, given the typical resolving power of existing and possible future echelle spectrographs. Achieving such high repetition rates, together with the desire to produce all comb modes with uniform intensity over the entire optical range, represent the only significant challenges in the design of a practical system. Frequency comb systems may remove wavelength calibration uncertainties from all practical spectroscopic experiments, even those combining data from different telescopes over many decades.

astro-ph

Photoionization Broadening of the 1S-2S Transition in a Beam of Atomic Hydrogen

We consider the excitation dynamics of the two-photon \sts transition in a beam of atomic hydrogen by 243 nm laser radiation. Specifically, we study the impact of ionization damping on the transition line shape, caused by the possibility of ionization of the 2S level by the same laser field. Using a Monte-Carlo simulation, we calculate the line shape of the \sts transition for the experimental geometry used in the two latest absolute frequency measurements (M. Niering {\it et al.}, PRL 84, 5496 (2000) and M. Fischer {\it et al.}, PRL 92, 230802 (2004)). The calculated line shift and line width are in excellent agreement with the experimentally observed values. From this comparison we can verify the values of the dynamic Stark shift coefficient for the \sts transition for the first time on a level of 15%. We show that the ionization modifies the velocity distribution of the metastable atoms, the line shape of the \sts transition, and has an influence on the derivation of its absolute frequency.

quant-ph

New Limits to the Drift of Fundamental Constants from Laboratory Measurements

We have remeasured the absolute $1S$-$2S$ transition frequency $ν_{\rm {H}}$ in atomic hydrogen. A comparison with the result of the previous measurement performed in 1999 sets a limit of $(-29\pm 57)$ Hz for the drift of $ν_{\rm {H}}$ with respect to the ground state hyperfine splitting $ν_{\rm {Cs}}$ in $^{133}$Cs. Combining this result with the recently published optical transition frequency in $^{199}$Hg$^+$ against $ν_{\rm {Cs}}$ and a microwave $^{87}$Rb and $^{133}$Cs clock comparison, we deduce separate limits on $\dotα/α= (-0.9\pm 2.9)\times 10^{-15}$ yr$^{-1}$ and the fractional time variation of the ratio of Rb and Cs nuclear magnetic moments $μ_{\rm {Rb}}/μ_{\rm {Cs}}$ equal to $(-0.5 \pm 1.7)\times 10^{-15}$ yr$^{-1}$. The latter provides information on the temporal behavior of the constant of strong interaction.

physics.optics

Astrophysical constraints on hypothetical variability of fundamental constants

(Abridged) Many-multiplet (MM) method applied to three inhomogeneous samples of Keck/HIRES quasar absorption spectra gives a shift in the value of the fine-structure constant of Delta alpha/alpha = (-5.4+/-1.2) 10^{-6} in the redshift range 0.2 < z < 3.7 (Murphy et al. 2003).The 1sigma error is, however, much too small and cannot be maintained by current observations of quasars. We present a modified MM method to set an upper limit on Delta alpha/alpha from a homogeneous sample of FeII lines identified in the up-to-date best quality VLT/UVES spectrum of HE 0515-4414. Our result is Delta alpha/alpha = (1.1+/-1.1) 10^{-5} at z = 1.149. Theoretical models of the fundamental physical interactions predict that the proton-to-electron mass ratio (mu = m_p/m_e) may relate to the shift in Delta alpha/alpha as Delta mu/mu = R Delta alpha/alpha. We use VLT/UVES high-resolution observations of molecular hydrogen H2 ultraviolet absorption lines at z = 3.025 toward Q 0347-3818 to bound the value of R. The obtained constraints on Delta ln mu = (2.1+/-3.6) 10^{-5} and on Delta ln alpha = (1.1+/-1.1) 10^{-5} rule out vary large values of |R| > 6.

astro-ph

Absolute Frequency Measurements of the Hg^+ and Ca Optical Clock Transitions with a Femtosecond Laser

The frequency comb created by a femtosecond mode-locked laser and a microstructured fiber is used to phase coherently measure the frequencies of both the Hg^+ and Ca optical standards with respect to the SI second as realized at NIST. We find the transition frequencies to be f_Hg=1 064 721 609 899 143(10) Hz and f_Ca=455 986 240 494 158(26) Hz, respectively. In addition to the unprecedented precision demonstrated here, this work is the precursor to all-optical atomic clocks based on the Hg^+ and Ca standards. Furthermore, when combined with previous measurements, we find no time variations of these atomic frequencies within the uncertainties of |(df_Ca/dt)/f_Ca| < 8 x 10^{-14} yr^{-1}, and |(df_Hg/dt)/f_Hg|< 30 x 10^{-14} yr^{-1}.

physics.atom-ph

Absolute frequency measurement of the In$^{+}$ clock transition with a mode-locked laser

The absolute frequency of the In$^{+}$ $5s^{2 1}S_{0}$ - $5s5p^{3}P_{0}$ clock transition at 237 nm was measured with an accuracy of 1.8 parts in $10^{13}$. Using a phase-coherent frequency chain, we compared the $^{1}S_{0}$ - $^{3}P_{0}$ transition with a methane-stabilized He-Ne laser at 3.39 $μ$m which was calibrated against an atomic cesium fountain clock. A frequency gap of 37 THz at the fourth harmonic of the He-Ne standard was bridged by a frequency comb generated by a mode-locked femtosecond laser. The frequency of the In$^{+}$ clock transition was found to be $1 267 402 452 899.92 (0.23)$ kHz, the accuracy being limited by the uncertainty of the He-Ne laser reference. This represents an improvement in accuracy of more than 2 orders of magnitude on previous measurements of the line and now stands as the most accurate measurement of an optical transition in a single ion.

quant-ph