Model-aided quantification of patient-specific benefit in mitigating radiation induced lymphopenia by particle therapy of cancer

Treatment-related lymphopenia is a frequent and clinically significant consequence of cancer therapy that can compromise immune-mediated tumor control and worsen patient outcomes. Despite its importance, no mechanistic framework exists to accurately predict the severity of lymphopenia from patient-specific data. Here, we present a biokinetic model that quantitatively describes lymphocyte depletion and recovery during and after radiotherapy, integrating radiation dose-volume distributions, blood circulation dynamics, and distinct kinetics of fast- and slow-recovering lymphocyte populations. The model was calibrated and validated using 56 independent clinical datasets encompassing various tumor sites and treatment modalities. It reproduces observed lymphocyte counts and enables prediction of individual severity of lymphopenia from baseline or early-treatment counts. Applying this framework, we demonstrate that particle therapy reduces lymphocyte depletion by ~30% compared with photon therapy, providing a quantitative explanation for its observed immune-sparing benefit. By linking radiation physics, immune kinetics, and clinical outcomes, our model establishes a mechanistically grounded predictive approach for anticipating systemic immune toxicity. Beyond radiotherapy, this framework offers a generalizable strategy for integrating early biological markers into treatment optimization, advancing personalized and immune-preserving cancer therapy.

physics.med-ph

The Biologically Effective Particle Number Ratio (BPNR): a new framework to quantify the therapeutic window in SFRT and other modalities

Spatially Fractionated Radiation Therapy (SFRT) produces highly heterogeneous dose distributions, for which conventional metrics such as peak, valley, or average dose can yield ambiguous or inconsistent estimates of therapeutic window changes. These dose descriptors are not uniquely linked to biological outcome, complicating comparisons between modalities. We introduce the Biologically Effective Particle Number Ratio (BPNR), a model-independent and outcome-based framework that quantifies therapeutic window changes using directly measurable delivery quantities rather than spatial dose metrics. BPNR is defined as the ratio of total particle numbers (proportional to monitor units, MU) required to reach specified levels of tumor control probability (TCP) and normal tissue complication probability (NTCP). The relative BPNR (RBPNR) compares therapeutic windows across modalities and avoids ambiguities of spatial dose averaging by relying solely on biological endpoints. As an illustration, we apply the framework to preclinical proton minibeam radiotherapy (pMBRT) versus conventional proton therapy. The absence of normal tissue complications at the highest tested MU in the pMBRT arm yields an RBPNR > 1.4, indicating a widened therapeutic window. The BPNR/RBPNR methodology provides a concise, experimentally grounded, and modality-agnostic way to quantify therapeutic window changes, with potential applications across SFRT, FLASH, high-LET radiation, and combination therapies.

physics.med-ph

Integrable Magnetic Fluid Hyperthermia Systems for 3D Magnetic Particle Imaging

Background: Combining magnetic particle imaging (MPI) and magnetic fluid hyperthermia (MFH) offers the ability to perform localized hyperthermia and magnetic particle imaging-assisted ther-mometry of hyperthermia treatment. This allows precise regional selective heating inside the body without invasive interventions. In current MPI-MFH platforms, separate systems are used, which require object transfer from one system to another. Here, we present the design, development and evaluation process for integrable MFH platforms, which extends a commercial MPI scanner with the functionality of MFH. Methods: The biggest issue of integrating magnetic fluid hyperthermia platforms into a magnetic par-ticle imaging system is the magnetic coupling of the devices, which induces high voltage in the imaging system, and is harming its components. In this paper we use a self-compensation approach derived from heuristic algorithms to protect the magnetic particle imaging scanner. The integrable platforms are evaluated regarding electrical and magnetic characteristics, cooling capability, field strength, the magnetic coupling to a replica of the magnetic particle imaging system's main solenoid and particle heating. Results: The MFH platforms generate suitable magnetic fields for magnetic heating of particles and are compatible with a commercial magnetic particle imaging scanner. In combination with the imaging system, selective heating with a gradient field and steerable heating positioning using the MPI focus fields are possible. Conclusion: The proposed MFH platforms serve as a therapeutic tool to unlock MFH functionality of a commercial magnetic particle imaging scanner, enabling its use in future preclinical trials of MPI-guided, spatially selective magnetic hyperthermia therapy.

physics.ins-det

Phase Object Reconstruction for 4D-STEM using Deep Learning

In this study we explore the possibility to use deep learning for the reconstruction of phase images from 4D scanning transmission electron microscopy (4D-STEM) data. The process can be divided into two main steps. First, the complex electron wave function is recovered for a convergent beam electron diffraction pattern (CBED) using a convolutional neural network (CNN). Subsequently a corresponding patch of the phase object is recovered using the phase object approximation (POA). Repeating this for each scan position in a 4D-STEM dataset and combining the patches by complex summation yields the full phase object. Each patch is recovered from a kernel of 3x3 adjacent CBEDs only, which eliminates common, large memory requirements and enables live processing during an experiment. The machine learning pipeline, data generation and the reconstruction algorithm are presented. We demonstrate that the CNN can retrieve phase information beyond the aperture angle, enabling super-resolution imaging. The image contrast formation is evaluated showing a dependence on thickness and atomic column type. Columns containing light and heavy elements can be imaged simultaneously and are distinguishable. The combination of super-resolution, good noise robustness and intuitive image contrast characteristics makes the approach unique among live imaging methods in 4D-STEM.

cond-mat.mtrl-sci

Real Time Integration Centre of Mass (riCOM) Reconstruction for 4D-STEM

A real-time image reconstruction method for scanning transmission electron microscopy (STEM) is proposed. With an algorithm requiring only the center of mass (COM) of the diffraction pattern at one probe position at a time, it is able to update the resulting image each time a new probe position is visited without storing any intermediate diffraction patterns. The results show clear features at higher spatial frequency, such as atomic column positions. It is also demonstrated that some common post processing methods, such as band pass filtering, can be directly integrated in the real time processing flow. Compared with other reconstruction methods, the proposed method produces high quality reconstructions with good noise robustness at extremely low memory and computational requirements. An efficient, interactive open source implementation of the concept is further presented, which is compatible with frame-based, as well as event-based camera/file types. This method provides the attractive feature of immediate feedback that microscope operators have become used to, e.g. conventional high angle annular dark field STEM imaging, allowing for rapid decision making and fine tuning to obtain the best possible images for beam sensitive samples at the lowest possible dose.

cond-mat.mtrl-sci

Phase retrieval from 4-dimensional electron diffraction datasets

We present a computational imaging mode for large scale electron microscopy data, which retrieves a complex wave from noisy/sparse intensity recordings using a deep learning approach and subsequently reconstructs an image of the specimen from the Convolutional Neural Network (CNN) predicted exit waves. We demonstrate that an appropriate forward model in combination with open data frameworks can be used to generate large synthetic datasets for training. In combination with augmenting the data with Poisson noise corresponding to varying dose-values, we effectively eliminate overfitting issues. The U-NET based architecture of the CNN is adapted to the task at hand and performs well while maintaining a relatively small size and fast performance. The validity of the approach is confirmed by comparing the reconstruction to well-established methods using simulated, as well as real electron microscopy data. The proposed method is shown to be effective particularly in the low dose range, evident by strong suppression of noise, good spatial resolution, and sensitivity to different atom types, enabling the simultaneous visualisation of light and heavy elements and making different atomic species distinguishable. Since the method acts on a very local scale and is comparatively fast it bears the potential to be used for near-real-time reconstruction during data acquisition.

cond-mat.mtrl-sci

Measuring magnetic moments of polydisperse ferrofluids utilizing the inverse Langevin function

The dipole strength of magnetic particles in a suspension is obtained by a graphical rectification of the magnetization curves based on the inverse Langevin function. The method yields the arithmetic and the harmonic mean of the particle distribution. It has an advantage compared to the fitting of magnetization curves to some appropriate mathematical model: It does not rely on assuming a particular distribution function of the particles.

cond-mat.soft

Self-assembly of magnetic iron oxide nanoparticles into cuboidal superstructures

This chapter describes the synthesis and some characteristics of magnetic iron oxide nanoparticles, mainly nanocubes, and focus on their self-assembly into crystalline cuboids in dispersion. The influence of external magnetic fields, the concentration of particles, and the temperature on the assembly process is experimentally investigated.

cond-mat.soft

$S^6$ and the geometry of nearly Kähler $6$-manifolds

We review results on and around the almost complex structure on $S^6$, both from a classical and a modern point of view. These notes have been prepared for the Workshop "(Non)-existence of complex structures on $S^6$" (\emph{Erste Marburger Arbeitsgemeinschaft Mathematik -- MAM-1}), held in Marburg in March 2017.

math.DG

Towards Picogram Detection of Superparamagnetic Iron-Oxide Particles Using a Gradiometric Receive Coil

Superparamagnetic iron-oxide nanoparticles can be used in a variety of medical applications like vascular or targeted imaging. Magnetic particle imaging (MPI) is a promising tomographic imaging technique that allows visualizing the 3D nanoparticle distribution concentration in a non-invasive manner. The two main strengths of MPI are high temporal resolution and high sensitivity. While the first has been proven in the assessment of dynamic processes like cardiac imaging, it is unknown how far the detection limit of MPI can be lowered. Within this work, we will present a highly sensitive gradiometric receive-coil unit combined with a noise-matching network tailored for the measurement of mice. The setup is capable of detecting 5 ng of iron in vitro at 2.14 sec acquisition time. In terms of iron concentration we are able to detect 156 μg/L marking the lowest value that has been reported for an MPI scanner so far. In vivo MPI mouse images of a 512 ng bolus at 21.5 ms acquisition time allow for capturing the flow of an intravenously injected tracer through the heart of a mouse. Since it has been rather difficult to compare detection limits across MPI publications we propose guidelines improving the comparability of future MPI studies.

physics.med-ph

Spinorial description of $\mathrm{SU}(3)$- and $G_2$-manifolds

We present a uniform description of $\mathrm{SU}(3)$-structures in dimension $6$ as well as $G_2$-structures in dimension $7$ in terms of a characterising spinor and the spinorial field equations it satisfies. We apply the results to hypersurface theory to obtain new embedding theorems, and give a general recipe for building conical manifolds. The approach also enables one to subsume all variations of the notion of a Killing spinor.

math.DG

The classification of naturally reductive homogeneous spaces in dimensions $n \leq 6$

We present a new method for classifying naturally reductive homogeneous spaces -- i.\,e.~homogeneous Riemannian manifolds admitting a metric connection with skew torsion that has parallel torsion \emph{and} curvature. This method is based on a deeper understanding of the holonomy algebra of connections with parallel skew torsion on Riemannian manifolds and the interplay of such a connection with the geometric structure on the given Riemannian manifold. It allows to reproduce by easier arguments the known classifications in dimensions $3,4$, and $5$, and yields as a new result the classification in dimension $6$. In each dimension, one obtains a `hierarchy' of degeneracy for the torsion form, which we then treat case by case. For the completely degenerate cases, we obtain results that are independent of the dimension. In some situations, we are able to prove that any Riemannian manifold with parallel skew torsion has to be naturally reductive. We show that a `generic' parallel torsion form defines a quasi-Sasakian structure in dimension $5$ and an almost complex structure in dimension $6$.

math.DG

Cocalibrated G_2-manifolds with Ricci flat characteristic connection

Any 7-dimensional cocalibrated G_2-manifold admits a unique connection $\nabla$ with skew symmetric torsion. We study these manifolds under the additional condition that the $\nabla$-Ricci tensor vanishes. In particular, we describe their geometry in case of a maximal number of $\nabla$-parallel vector fields.

math.DG

Sp(3) structures on 14-dimensional manifolds

The present article investigates Sp(3) structures on 14-dimensional Riemannian manifolds, a continuation of the recent study of manifolds modeled on rank two symmetric spaces (here: SU(6)/Sp(3)). We derive topological criteria for the existence of such a structure and construct large families of homogeneous examples. As a by-product, we prove a general uniqueness criterion for characteristic connections of G structures and that the notions of biinvariant, canonical, and characteristic connections coincide on Lie groups with biinvariant metric.

math.DG

Spherical sample holders to improve the susceptibility measurement of superparamagnetic materials

The design of two custom sample holders with a spherical cavity for commercial vibrating sample magnetometer systems is described. For such cavities the magnetization M and the internal magnetic field Hi of a sample are both homogeneous. Consequently, the material parameter M(Hi) of a sample can be determined even for liquids and powders with a high magnetic susceptibility.

physics.ins-det

A note on the magnetic spatial forcing of a ferrofluid layer

We report on the response of a thin layer of ferrofluid to a spatially modulated magnetic field. This field is generated by means of a constant current in a special arrangement of aluminum wires. The full surface profile of the liquid layer is recorded by means of the absorption of X-rays. The outcome is analyzed particularly with regard to the magnetic self focusing effect under a deformable fluid layer.

physics.flu-dyn

The second Dirac eigenvalue of a nearly parallel $G_2$-manifold

We investigate the second Dirac eigenvalue on Riemannian manifolds admitting a Killing spinor. In small dimensions the whole Dirac spectrum depends on special eigenvalues on functions and 1-forms. We compute and discuss the formulas in dimension $n = 7$.

math.DG

On the topology and the geometry of SO(3)-manifolds

Consider the nonstandard embedding of SO(3) into SO(5) given by the 5-dimensional irreducible representation of SO(3), henceforth called SO(3)_\ir. In this note, we study the topology and the differential geometry of 5-dimensional Riemannian manifolds carrying such an SO(3)_\ir structure, i.\,e. with a reduction of the frame bundle to SO(3)_\ir.

math.DG