SearcharxivSearch

arXiv subjects

Thomas Gustavsson

Publications and source records attributed to Thomas Gustavsson.

6 recordsLinked to original sources

Design, simulation and performance of the resistive-anode PICOSEC Micromegas detector

The PICOSEC Micromegas detector is a Micro-Pattern Gaseous Detector concept developed to achieve tens of picosecond timing resolution for charged particle detection by combining a Cherenkov radiator with a two-stage Micromegas amplification structure. To improve operational robustness, a resistive anode has been implemented using a DLC layer deposited on a Kapton substrate. While this design enhances detector stability, the resistive layer may influence rate capability, signal formation, and detector capacitance, altering timing performance. This work presents a comprehensive study of a resistive design, including an analytical model and finite-element simulations to quantify rate-dependent gain reduction due to ohmic voltage drop on the resistive layer. An analytical solution for the voltage across a finite-size resistive layer is derived, and a numerical model is developed to evaluate gain suppression under intense particle fluxes. The impact of the resistive layer on signal formation is investigated using time-dependent weighting fields and the Garfield++ simulation framework. The contribution of signal components induced by the resistive layer is quantified, and preservation of the signal leading edge is found for surface resistivities above 100 kohm per square. Single-channel resistive-anode prototypes were designed, constructed, and experimentally characterized. Laboratory measurements using single photoelectrons and power spectral density analysis show the predicted reduction in signal amplitude while preserving the leading edge. Muon beam tests with CsI and DLC photocathodes demonstrate a time resolution of 11.5 ps for CsI, comparable to 11.9 ps for the metallic-anode device, showing the suitability of the resistive design for precision timing applications.

physics.ins-det

A large area 100 channel Picosec Micromegas detector with sub 20 ps time resolution

The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a semi-transparent photocathode and a Micromegas amplification structure. The first proof of concept single-channel small area prototype was able to achieve time resolution below 25 ps. One of the crucial aspects in the development of the precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm$^2$ suffered from degraded timing resolution due to the non-uniformity of the preamplification gap. A new 100 cm$^2$ detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over measured pads and a time resolution below 25 ps. More recent measurements with a new thinner drift gap detector module and newly developed RF pulse amplifiers show that the resolution can be enhanced to a level of 17~ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

physics.ins-det

Towards robust PICOSEC Micromegas precise timing detectors

The PICOSEC Micromegas (MM) detector is a precise timing gaseous detector consisting of a Cherenkov radiator combined with a photocathode and a MM amplifying structure. A 100-channel non-resistive PICOSEC MM prototype with 10x10 cm^2 active area equipped with a Cesium Iodide (CsI) photocathode demonstrated a time resolution below 18 ps. The objective of this work is to improve the PICOSEC MM detector robustness aspects; i.e. integration of resistive MM and carbon-based photocathodes; while maintaining good time resolution. The PICOSEC MM prototypes have been tested in laboratory conditions and successfully characterised with 150 GeV/c muon beams at the CERN SPS H4 beam line. The excellent timing performance below 20 ps for an individual pad obtained with the 10x10 cm^2 area resistive PICOSEC MM of 20 MOhm/sq showed no significant time resolution degradation as a result of adding a resistive layer. A single-pad prototype equipped with a 12 nm thick Boron Carbide (B4C) photocathode presented a time resolution below 35 ps; opening up new possibilities for detectors with robust photocathodes. The results made the concept more suitable for the experiments in need of robust detectors with good time resolution.

physics.ins-det

The Excited State Dynamics of a Mutagenic Cytidine Etheno Adduct Investigated by Combining Time-Resolved Spectroscopy and Quantum Mechanical Calculations

Joint femtosecond fluorescence upconversion experiments and theoretical calculations provide a hitherto unattained degree of characterization and understanding of the mutagenic etheno adduct 3,N4-etheno-2'-deoxycytidine ($ε$dC) excited state relaxation. This endogenously formed lesion is attracting great interest because of its ubiquity in human tissues and its highly mutagenic properties. The $ε$dC fluorescence is modified with respect to that of the canonical base dC, with a 3-fold increased lifetime and quantum yield at neutral pH. This behavior is amplified upon protonation of the etheno ring ($ε$dCH+). Quantum mechanical calculations show that the lowest energy state $π$$π$*1 is responsible for the fluorescence and that the main nonradiative decay pathway to the ground state goes through an ethene-like conical intersection, involving the out-of-plane motion of the C5 and C6 substituents. This conical intersection is lower in energy than the $π$$π$* state ($π$$π$*1) minimum, but a sizable energy barrier explains the increase of $ε$dC and $ε$dCH+ fluorescence lifetimes with respect to that of dC.

physics.class-ph

Timing Performance of a Micro-Channel-Plate Photomultiplier Tube

The spatial dependence of the timing performance of the R3809U-50 Micro-Channel-Plate PMT (MCP-PMT) by Hamamatsu was studied in high energy muon beams. Particle position information is provided by a GEM tracker telescope, while timing is measured relative to a second MCP-PMT, identical in construction. In the inner part of the circular active area (radius r$<$5.5\,mm) the time resolution of the two MCP-PMTs combined is better than 10~ps. The signal amplitude decreases in the outer region due to less light reaching the photocathode, resulting in a worse time resolution. The observed radial dependence is in quantitative agreement with a dedicated simulation. With this characterization, the suitability of MCP-PMTs as $\text{t}_\text{0}$ reference detectors has been validated.

physics.ins-det

Fast Timing for High-Rate Environments with Micromegas

The current state of the art in fast timing resolution for existing experiments is of the order of 100 ps on the time of arrival of both charged particles and electromagnetic showers. Current R&D on charged particle timing is approaching the level of 10 ps but is not primarily directed at sustained performance at high rates and under high radiation (as would be needed for HL-LHC pileup mitigation). We demonstrate a Micromegas based solution to reach this level of performance. The Micromegas acts as a photomultiplier coupled to a Cerenkov-radiator front window, which produces sufficient UV photons to convert the ~100 ps single-photoelectron jitter into a timing response of the order of 10-20 ps per incident charged particle. A prototype has been built in order to demonstrate this performance. The first laboratory tests with a pico-second laser have shown a time resolution of the order of 27 ps for ~50 primary photoelectrons, using a bulk Micromegas readout.