SearcharxivSearch

arXiv subjects

Thomas Koffas

Publications and source records attributed to Thomas Koffas.

6 recordsLinked to original sources

Advancements and future expansions of the Caribou DAQ system

Caribou is a versatile data acquisition (DAQ) system developed within several collaborative frameworks (CERN EP R&D, DRD3, AIDAinnova, and Tangerine) to support laboratory and test-beam characterization of novel silicon pixel detectors. It combines a custom Control and Readout (CaR) board with a Xilinx Zynq System-on-Chip (SoC) running project-wide shared firmware and software stacks. The system architecture emphasizes reusability, flexibility, and ease of integration. The CaR board provides essential interfaces such as programmable power supplies, voltage and current references, high-speed ADCs, and configurable I/O lines for detector control and readout. The SoC runs an embedded Linux distribution built with PetaLinux and integrates two main components: Peary, a C++ embedded DAQ application providing hardware abstraction, configuration management, logging, and multi-device control through Command Line (CLI) and Python interfaces; and Boreal, a common Caribou FPGA firmware framework offering reusable modules and automated build workflows for user-specific bit files. The next major milestone in Caribou's evolution is the transition to version 2.0, based on a Zynq UltraScale+ System-on-Module (SoM) architecture. This paper presents the recent progress and future prospects of the project and describes recent hardware, firmware, and software developments preparing the system for the upcoming CaR board v2.0.

physics.ins-det

Caribou - A versatile data acquisition system for silicon pixel detector prototyping

Caribou is a versatile data acquisition system used in multiple collaborative frameworks (CERN EP R&D, DRD3, AIDAinnova, Tangerine) for laboratory and test-beam qualification of novel silicon pixel detector prototypes. The system is built around a common hardware, firmware and software stack shared accross different projects, thereby drastically reducing the development effort and cost. It consists of a custom Control and Readout (CaR) board and a commercial Xilinx Zynq System-on-Chip (SoC) platform. The SoC platform runs a full Yocto distribution integrating the custom software framework (Peary) and a custom FPGA firmware built within a common firmware infrastructure (Boreal). The CaR board provides a hardware environment featuring various services such as powering, slow-control, and high-speed data links for the target detector prototype. Boreal and Peary, in turn, offer firmware and software architectures that enable seamless integration of control and readout for new devices. While the first version of the system used a SoC platform based on the ZC706 evaluation board, migration to a Zynq UltraScale+ architecture is progressing towards the support of the ZCU102 board and the ultimate objective of integrating the SoC functionality directly into the CaR board, eliminating the need for separate evaluation boards. This paper describes the Caribou system, focusing on the latest project developments and showcasing progress and future plans across its hardware, firmware, and software components.

physics.ins-det

Design, fabrication and testing of Al/p-Si Schottky and pn junctions for radiation studies

Strip and pixels sensors, fabricated on high resistivity silicon substrate, normally of p-type, are used in detectors for High Energy Physics (HEP) typically in a hybrid detector assembly. Furthermore, and owing to their inherent advantages over hybrid sensors, Monolithic Active Pixel Sensors (MAPS) fabricated in CMOS technology have been increasingly implemented in HEP experiments. In all cases, their use in higher radiation areas (HL-LHC and beyond) will require options to improve their radiation hardness and time resolution. These aspects demand a deep understanding of their radiation damage and reliable models to predict their behaviours at high fluences. As a first step, we fabricated several Schottky and n-on-p diodes, to allow a comparison of results and provide a backup solution for test devices, on 6 or 4-inch p-type silicon wafers with 50 {\mu}m epitaxial thickness and of doping concentration as they are normally used in HEP detectors and CMOS MAPS devices. In this paper, details of the design and fabrication process, along with test results of the fabricated devices before irradiation, will be provided. Additional test results on irradiated devices will be provided in subsequent publications.

physics.ins-det

TCAD Simulations of Humidity-Induced Breakdown of Silicon Sensors

The breakdown voltage of silicon sensors is known to be affected by the ambient humidity. To understand the sensor's humidity sensitivity, Synopsys TCAD was used to simulate n-in-p sensors for different effective relative humidities. Photon emission of hot electrons was imaged with a microscope to locate breakdown in the edge-region of the sensor. The Top-Transient Current Technique was used to measure charge transport near the surface in the breakdown region of the sensor. Using the measurements and simulations, the evolution of the electric field with relative humidity and the carrier densities towards breakdown in the periphery of p-bulk silicon sensors are investigated.

physics.ins-det

An RF-only ion-funnel for extraction from high-pressure gases

An RF ion-funnel technique has been developed to extract ions from a high-pressure (10 bar) noble-gas environment into vacuum ($10^{-6}$ mbar). Detailed simulations have been performed and a prototype has been developed for the purpose of extracting $^{136}$Ba ions from Xe gas with high efficiency. With this prototype, ions have been extracted for the first time from high-pressure xenon gas and argon gas. Systematic studies have been carried out and compared to the simulations. This demonstration of extraction of ions with mass comparable to that of the gas generating the high-pressure into vacuum has applications to Ba tagging from a Xe-gas time-projection chamber (TPC) for double beta decay as well as to the general problem of recovering trace amounts of an ionized element in a heavy (m$>40$ u) carrier gas.

physics.ins-det

Performance of a Full-Size Small-Strip Thin Gap Chamber Prototype for the ATLAS New Small Wheel Muon Upgrade

The instantaneous luminosity of the Large Hadron Collider at CERN will be increased up to a factor of five with respect to the present design value by undergoing an extensive upgrade program over the coming decade. The most important upgrade project for the ATLAS Muon System is the replacement of the present first station in the forward regions with the so-called New Small Wheels (NSWs). The NSWs will be installed during the LHC long shutdown in 2018/19. Small-Strip Thin Gap Chamber (sTGC) detectors are designed to provide fast trigger and high precision muon tracking under the high luminosity LHC conditions. To validate the design, a full-size prototype sTGC detector of approximately 1.2 $\times$ $1.0\, \mathrm{m}^2$ consisting of four gaps has been constructed. Each gap provides pad, strip and wire readouts. The sTGC intrinsic spatial resolution has been measured in a $32\, \mathrm{GeV}$ pion beam test at Fermilab. At perpendicular incidence angle, single gap position resolutions of about $50\,\mathrm{μm}$ have been obtained, uniform along the sTGC strip and perpendicular wire directions, well within design requirements. Pad readout measurements have been performed in a $130\, \mathrm{GeV}$ muon beam test at CERN. The transition region between readout pads has been found to be $4\,\mathrm{mm}$, and the pads have been found to be fully efficient.

physics.ins-det