SearcharxivSearch

arXiv subjects

Thomas R Else

Publications and source records attributed to Thomas R Else.

3 recordsLinked to original sources

PhotIQA: A photoacoustic image data set with image quality ratings

Image quality assessment (IQA) is crucial in the evaluation stage of novel algorithms operating on images, including traditional and machine learning based methods. Due to the lack of available quality-rated medical images, most commonly used full-reference IQA measures have been developed and tested for natural images. Reported pitfalls and inconsistencies arising when applying such measures for medical images are not surprising, as they rely on different properties than natural images. In photoacoustic imaging (PAI), especially, standard benchmarking approaches for assessing the quality of image reconstructions are lacking. PAI is a multi-physics imaging modality, in which two inverse problems have to be solved, which makes the application of IQA measures uniquely challenging due to both, acoustic and optical, artifacts. To support the development and testing of IQA measures we assembled PhotIQA, a data set consisting of 1134 photoacoustic images. The images were rated by five experts across five quality properties in a full-reference setting, where the detailed rating enables usage beyond PAI. The data set with the images and corresponding ratings is publicly available on Zenodo.

eess.IV

Parameter choices in HaarPSI for IQA with medical images

When developing machine learning models, image quality assessment (IQA) measures are a crucial component for the evaluation of obtained output images. However, commonly used full-reference IQA (FR-IQA) measures have been primarily developed and optimized for natural images. In many specialized settings, such as medical images, this poses an often overlooked problem regarding suitability. In previous studies, the FR-IQA measure HaarPSI showed promising behavior regarding generalizability. The measure is based on Haar wavelet representations and the framework allows optimization of two parameters. So far, these parameters have been aligned for natural images. Here, we optimize these parameters for two medical image data sets, a photoacoustic and a chest X-ray data set, with IQA expert ratings. We observe that they lead to similar parameter values, different to the natural image data, and are more sensitive to parameter changes. We denote the novel optimized setting as HaarPSI$_{MED}$, which improves the performance of the employed medical images significantly (p<0.05). Additionally, we include an independent CT test data set that illustrates the generalizability of HaarPSI$_{MED}$, as well as visual examples that qualitatively demonstrate the improvement. The results suggest that adapting common IQA measures within their frameworks for medical images can provide a valuable, generalizable addition to employment of more specific task-based measures.

eess.IV

A study on the adequacy of common IQA measures for medical images

Image quality assessment (IQA) is standard practice in the development stage of novel machine learning algorithms that operate on images. The most commonly used IQA measures have been developed and tested for natural images, but not in the medical setting. Reported inconsistencies arising in medical images are not surprising, as they have different properties than natural images. In this study, we test the applicability of common IQA measures for medical image data by comparing their assessment to manually rated chest X-ray (5 experts) and photoacoustic image data (2 experts). Moreover, we include supplementary studies on grayscale natural images and accelerated brain MRI data. The results of all experiments show a similar outcome in line with previous findings for medical images: PSNR and SSIM in the default setting are in the lower range of the result list and HaarPSI outperforms the other tested measures in the overall performance. Also among the top performers in our experiments are the full reference measures FSIM, LPIPS and MS-SSIM. Generally, the results on natural images yield considerably higher correlations, suggesting that additional employment of tailored IQA measures for medical imaging algorithms is needed.

eess.IV