SearcharxivSearch

arXiv subjects

Thorir Mar Ingolfsson

Publications and source records attributed to Thorir Mar Ingolfsson.

At least 19 recordsLinked to original sources

S-CEReBrO: Breaking the Memory Barrier in Continuous EEG Monitoring

Foundation models offer a promising paradigm for Electroencephalography (EEG) analysis, leveraging generalizable representations from vast unlabeled datasets. Yet, Transformer-based architectures face a critical bottleneck: global attention mechanisms couple the attention memory state to the signal duration, causing memory overflow during continuous monitoring. To address this, we introduce S-CEReBrO (Streaming CEReBrO), an evolution of the CEReBrO architecture designed for continuous monitoring. Our novel Windowed Alternating Attention mechanism factorizes attention computation into fixed-size spatiotemporal windows, so that under streaming, only the active window remains resident and the attention state is bounded independently of signal duration. Empirical scaling analysis shows that windowed alternating attention can process signals 100X longer than full self-attention and 3X longer than low-rank linear attention. Compared to low-rank linear attention on long contexts, windowed alternating attention requires 55% of the memory while increasing inference throughput by 2.1X. Pre-trained on >25,000 hours of recordings from >12,000 subjects, S-CEReBrO achieves state-of-the-art performance on 7 of 11 downstream tasks, with up to 60% fewer parameters. This work represents a significant step toward the realization of efficient, generalizable, and continuous EEG monitoring. An accompanying code repository is available. An accompanying code repository is available.

cs.LG

Quantizing Recursive Reasoning Models

Recursive reasoning models solve hard puzzles by applying compact, weight-tied blocks over many refinement steps. Because these blocks are reused many times, quantizing them creates a unique dynamical problem: the quantization error is incurred at every step. While 8-bit quantization (integer or float) preserves accuracy, moving to a per-tensor 4-bit format causes a systematic bias to accumulate. The ensuing drift catastrophically degrades exact-solution accuracy on Sudoku from 84.1% to 0.0% (only ~25% of cells correct). In this work, we show that this collapse is caused by activation-scaling granularity rather than bit-width or number format. Crucially, moving to per-block scaling completely restores the transition. To implement this, we apply MXInt4, a blockwise integer activation format, to recursive reasoning models. It is competitive with blockwise float formats on our tasks, while keeping integer elements and power-of-two block scales. Finally, recursion depth and reuse modulate quantization sensitivity, with the deepest architecture we test (the EqR equilibrium model) the most sensitive. Yet blockwise scaling overcomes this vulnerability, staying robust across these architectures and transferring to the open-ended ARC-AGI benchmark.

cs.LG

Evaluation of EEG Foundation Models for Event-Based Burst-Suppression Detection in ICU

Burst suppression (BS) is a clinically relevant electroencephalographic (EEG) pattern used to monitor sedation depth and brain activity in critically ill patients, particularly during induced coma in Intensive Care Units (ICUs). Automatic burst detection remains challenging because BS patterns vary substantially between patients and annotated datasets are scarce. Recently, EEG Foundation Models (FMs) have shown promise across several downstream EEG applications, but their usefulness for BS detection remains unexplored. We present the first study to evaluate EEG FMs for burst detection in reduced-montage ICU EEG without patient-specific calibration. We compare REVE-base, LUNA-large and LuMamba-Tiny with an adaptive thresholding baseline and a task-specific EEGNet baseline. Additionally, we complement conventional EEG window-based classification with event-based burst detection evaluation. This helps assessing clinically whether burst episodes are correctly detected, reducing the impact of expected annotation variability. The best model, REVE-base, achieved the highest event-based F1-score ($0.868 \pm 0.167$) and reduced burst-per-minute error by 52.1% and 36.2% compared to EEGNet and adaptive thresholding respectively, supporting FMs for scalable EEG monitoring in ICU. Ablation experiments showed that full fine-tuning was the most effective adaptation strategy with respect to frozen-backbone training, two-step fine-tuning, and LoRA-based adaptation, improving event-based F1-score over frozen-backbone training by up to $+0.102$ for LUNA-large. With reduced labeled datasets, pretrained REVE-base outperformed random initialization by $+0.723$ event-based F1 points at 25% of the cohort, demonstrating the benefit of pretraining FM representations when adapted to burst detection with limited labeled data.

eess.SP

LuMamba: Latent Unified Mamba for Electrode Topology-Invariant and Efficient EEG Modeling

Electroencephalography (EEG) enables non-invasive monitoring of brain activity across clinical and neurotechnology applications, yet building foundation models for EEG remains challenging due to differing electrode topologies and computational scalability, as Transformer architectures incur quadratic sequence complexity. As a joint solution, we propose LuMamba (Latent Unified Mamba), a self-supervised framework combining topology-invariant encodings with linear-complexity state-space modeling, using LUNA's learned-query cross-attention mechanism for channel unification, and FEMBA's bidirectional Mamba blocks for efficient temporal modeling. Within this architecture, we provide the first systematic investigation of the Latent-Euclidean Joint-Embedding Predictive Architecture (LeJEPA) for biosignal learning. Pre-trained on over 21,000 hours of unlabeled EEG from the TUEG corpus, LuMamba is evaluated on five downstream tasks spanning abnormality detection, artifact recognition, and mental condition classification across electrode configurations ranging from 16 to 26 channels. In the pre-training objective, masked reconstruction alone yields structured but less generalizable representations, while LeJEPA alone produces diffuse embeddings; combining both objectives achieves the most robust performance. With only 4.6M parameters, LuMamba attains 80.99% balanced accuracy on TUAB and achieves state-of-art performance on Alzheimer's detection (0.97 AUPR), while requiring 377x fewer FLOPS than state-of-art models at equivalent sequence lengths and scaling to 12x longer sequences before reaching typical GPU memory limits. Code is available at https://github.com/pulp-bio/biofoundation.

cs.AI

PanLUNA: An Efficient and Robust Query-Unified Multimodal Model for Edge Biosignal Intelligence

Physiological foundation models (FMs) have shown promise for biosignal representation learning, yet most remain confined to a single modality such as EEG, ECG, or PPG, largely because paired multimodal datasets are scarce. In this paper, we present PanLUNA, a compact 5.4M-parameter pan-modal FM that jointly processes EEG, ECG, and PPG within a single shared encoder. Extending LUNA's channel-unification module, PanLUNA treats multimodal channels as entries in a unified query set augmented with sensor-type embeddings, enabling efficient cross-modal early fusion while remaining inherently robust to missing modalities at inference time. Despite its small footprint, PanLUNA matches or exceeds models up to 57$\times$ larger: 81.21% balanced accuracy on TUAB abnormal EEG detection and state-of-the-art 0.7416 balanced accuracy on HMC multimodal sleep staging. Quantization-aware training with INT8 weights recovers $\geq$96% of full-precision performance, and deployment on the GAP9 ultra-low-power RISC-V microcontroller for wearables achieves 325.6 ms latency and 18.8 mJ per 10-second, 12-lead ECG inference, and 1.206 s latency at 68.65 mJ for multimodal 5-channel sleep staging over 30-second epochs.

cs.AI

FEMBA on the Edge: Physiologically-Aware Pre-Training, Quantization, and Deployment of a Bidirectional Mamba EEG Foundation Model on an Ultra-low Power Microcontroller

Objective: To enable continuous, long-term neuro-monitoring on wearable devices by overcoming the computational bottlenecks of Transformer-based Electroencephalography (EEG) foundation models and the quantization challenges inherent to State-Space Models (SSMs). Methods: We present FEMBA, a bidirectional Mamba architecture pre-trained on over 21,000 hours of EEG. We introduce a novel Physiologically-Aware pre-training objective, consisting of a reconstruction with low-pass filtering, to prioritize neural oscillations over high-frequency artifacts. To address the activation outliers common in SSMs, we employ Quantization-Aware Training (QAT) to compress the model to 2-bit weights. The framework is deployed on a parallel ultra-low-power RISC-V microcontroller (GAP9) using a custom double-buffered memory streaming scheme. Results: The proposed low-pass pre-training improves downstream AUROC on TUAB from 0.863 to 0.893 and AUPR from 0.862 to 0.898 compared to the best contrastive baseline. QAT successfully compresses weights with negligible performance loss, whereas standard post-training quantization degrades accuracy by approximately \textbf{30\%}. The embedded implementation achieves deterministic real-time inference (\textbf{1.70~s} per 5~s window) and reduces the memory footprint by \textbf{74\%} (to $\approx$2~MB), achieving competitive accuracy with up to \textbf{27$\times$} fewer FLOPs than Transformer benchmarks. Conclusion: FEMBA demonstrates that Mamba-based foundation models can be effectively quantized and deployed on extreme-edge hardware without sacrificing the representation quality required for robust clinical analysis. Significance: This work establishes the first full-stack framework for deploying large-scale EEG foundation models on ultra-low-power wearables, facilitating continuous, SSM based monitoring for epilepsy and sleep disorders.

eess.SP

TinyMyo: a Tiny Foundation Model for Flexible EMG Signal Processing at the Edge

Objective: Surface electromyography (EMG) is a non-invasive sensing modality widely used in biomechanics, rehabilitation, prosthetic control, and human-machine interfaces. Despite decades of use, achieving robust generalization across subjects, recording systems, and acquisition protocols remains challenging. While foundation models (FMs) are gaining traction for EMG, existing approaches remain limited to single downstream tasks and lack deployability on embedded platforms. This work addresses these limitations. Methods: We present TinyMyo, a lightweight FM based on a Transformer encoder architecture. The model is pre-trained in a self-supervised manner using masked reconstruction on publicly available datasets. With only 3.6M parameters, TinyMyo is designed to support multiple downstream tasks through minimal task-specific head adaptations. Results: We demonstrate generalization across hand gesture classification, hand kinematic regression, speech production and speech recognition, with performance comparable to or surpassing the state of the art (SoA), and model size below 5M parameters. We achieve SoA results compared to previous FM-based works on the NinaPro DB5 (89.4%), UCI-EMG (97.56%), and EPN-612 (96.74%) datasets. We demonstrate the first-time deployment of an EMG FM on an ultra-low power microcontroller (GAP9), with an inference time of 0.785 s, energy of 44.91 mJ and power envelope of 57.18 mW. Conclusion: TinyMyo demonstrates that compact, self-supervised EMG FM can guarantee strong generalization across multiple downstream tasks while remaining compatible with low-power edge devices. Significance: TinyMyo is the first EMG FM for ultra-low power edge devices, enabling scalable and energy-efficient sensing for motor intent decoding, neuromuscular assessment, and biosignal driven human-machine interaction.

eess.SP

GAPses: Versatile smart glasses for comfortable and fully-dry acquisition and parallel ultra-low-power processing of EEG and EOG

Recent advancements in head-mounted wearable technology are revolutionizing the field of biopotential measurement, but the integration of these technologies into practical, user-friendly devices remains challenging due to issues with design intrusiveness, comfort, and data privacy. To address these challenges, this paper presents GAPses, a novel smart glasses platform designed for unobtrusive, comfortable, and secure acquisition and processing of electroencephalography (EEG) and electrooculography (EOG) signals. We introduce a direct electrode-electronics interface with custom dry soft electrodes to enhance comfort for long wear. An integrated parallel ultra-low-power RISC-V processor (GAP9, Greenwaves Technologies) processes data at the edge, thereby eliminating the need for continuous data streaming through a wireless link, enhancing privacy, and increasing system reliability in adverse channel conditions. We demonstrate the broad applicability of the designed prototype through validation in a number of EEG-based interaction tasks, including alpha waves, steady-state visual evoked potential analysis, and motor movement classification. Furthermore, we demonstrate an EEG-based biometric subject recognition task, where we reach a sensitivity and specificity of 98.87% and 99.86% respectively, with only 8 EEG channels and an energy consumption per inference on the edge as low as 121 $μJ$. Moreover, in an EOG-based eye movement classification task, we reach an accuracy of 96.68% on 11 classes, resulting in an information transfer rate of 94.78 bit/min, which can be further increased to 161.43 bit/min by reducing the accuracy to 81.43%. The deployed implementation has an energy consumption of 40 $μJ$ per inference and a total system power of only 12.4 mW, of which only 1.61% is used for classification, allowing for continuous operation of more than 22 h with a small 75 mAh battery.

eess.SP

LUNA: Efficient and Topology-Agnostic Foundation Model for EEG Signal Analysis

Electroencephalography (EEG) offers a non-invasive lens into human brain activity, but building large-scale models is hampered by topological heterogeneity: each public EEG data defines its own electrode layout, limiting generalization. We introduce LUNA (Latent Unified Network Architecture), a self-supervised foundation model that reconciles disparate electrode geometries while scaling linearly -- not quadratically -- with channel count. LUNA compresses multi-channel EEG into a fixed-size, topology-agnostic latent space via learned queries and cross-attention. Downstream transformer blocks then operate exclusively on this latent representation using patch-wise temporal self-attention, decoupling computation from electrode count. Pre-trained on TUEG and Siena (over 21,000 hours of raw EEG across diverse montages) using a masked-patch reconstruction objective, LUNA transfers effectively to four downstream tasks: abnormality detection, artifact rejection, slowing classification, and emotion recognition. It demonstrates highly competitive performance across several benchmarks, achieving state-of-the-art results on TUAR and TUSL, e.g., 0.921 AUROC on TUAR, while reducing FLOPs by 300x and trimming GPU memory use by up to 10x. Critically, these gains are consistent across all evaluated electrode configurations. Code is available at https://github.com/pulp-bio/BioFoundation

cs.LG

CEReBrO: Compact Encoder for Representations of Brain Oscillations Using Efficient Alternating Attention

Electroencephalograph (EEG) is a crucial tool for studying brain activity. Recently, self-supervised learning methods leveraging large unlabeled datasets have emerged as a potential solution to the scarcity of widely available annotated EEG data. However, current methods suffer from at least one of the following limitations: i) sub-optimal EEG signal modeling, ii) model sizes in the hundreds of millions of trainable parameters, and iii) reliance on private datasets and/or inconsistent public benchmarks, hindering reproducibility. To address these challenges, we introduce a Compact Encoder for Representations of Brain Oscillations using alternating attention (CEReBrO), a new small EEG foundation model. Our tokenization scheme represents EEG signals at a per-channel patch granularity. We propose an alternating attention mechanism that jointly models intra-channel temporal dynamics and inter-channel spatial correlations, achieving 2x speed improvement with 6x less memory required compared to standard self-attention. We present several model sizes ranging from 3.6 million to 85 million parameters. Pre-trained on over 20,000 hours of publicly available scalp EEG recordings with diverse channel configurations, our models set new benchmarks in emotion detection and seizure detection tasks, with competitive performance in anomaly classification and gait prediction. This validates our models' effectiveness and efficiency.

cs.LG

FEMBA: Efficient and Scalable EEG Analysis with a Bidirectional Mamba Foundation Model

Accurate and efficient electroencephalography (EEG) analysis is essential for detecting seizures and artifacts in long-term monitoring, with applications spanning hospital diagnostics to wearable health devices. Robust EEG analytics have the potential to greatly improve patient care. However, traditional deep learning models, especially Transformer-based architectures, are hindered by their quadratic time and memory complexity, making them less suitable for resource-constrained environments. To address these challenges, we present FEMBA (Foundational EEG Mamba + Bidirectional Architecture), a novel self-supervised framework that establishes new efficiency benchmarks for EEG analysis through bidirectional state-space modeling. Unlike Transformer-based models, which incur quadratic time and memory complexity, FEMBA scales linearly with sequence length, enabling more scalable and efficient processing of extended EEG recordings. Trained on over 21,000 hours of unlabeled EEG and fine-tuned on three downstream tasks, FEMBA achieves competitive performance in comparison with transformer models, with significantly lower computational cost. Specifically, it reaches 81.82% balanced accuracy (0.8921 AUROC) on TUAB and 0.949 AUROC on TUAR, while a tiny 7.8M-parameter variant demonstrates viability for resource-constrained devices. These results pave the way for scalable, general-purpose EEG analytics in both clinical and highlight FEMBA as a promising candidate for wearable applications.

cs.LG

Finetuning and Quantization of EEG-Based Foundational BioSignal Models on ECG and PPG Data for Blood Pressure Estimation

Blood pressure (BP) is a key indicator of cardiovascular health. As hypertension remains a global cause of morbidity and mortality, accurate, continuous, and non-invasive BP monitoring is therefore of paramount importance. Photoplethysmography (PPG) and electrocardiography (ECG) can potentially enable continuous BP monitoring, yet training accurate and robust machine learning (ML) models remains challenging due to variability in data quality and patient-specific factors. Recently, multiple research groups explored Electroencephalographic (EEG)--based foundation models and demonstrated their exceptional ability to learn rich temporal resolution. Considering the morphological similarities between different biosignals, the question arises of whether a model pre-trained on one modality can effectively be exploited to improve the accuracy of a different signal type. In this work, we take an initial step towards generalized biosignal foundation models by investigating whether model representations learned from abundant EEG data can effectively be transferred to ECG/PPG data solely with fine-tuning, without the need for large-scale additional pre-training, for the BP estimation task. Evaluations on the MIMIC-III and VitalDB datasets demonstrate that our approach achieves near state-of-the-art accuracy for diastolic BP (mean absolute error of 1.57 mmHg) and surpasses by 1.5x the accuracy of prior works for systolic BP (mean absolute error 2.72 mmHg). Additionally, we perform dynamic INT8 quantization, reducing the smallest model size by over 3.5x (from 13.73 MB down to 3.83 MB) while preserving performance, thereby enabling unobtrusive, real-time BP monitoring on resource-constrained wearable devices.

eess.SP

Train-On-Request: An On-Device Continual Learning Workflow for Adaptive Real-World Brain Machine Interfaces

Brain-machine interfaces (BMIs) are expanding beyond clinical settings thanks to advances in hardware and algorithms. However, they still face challenges in user-friendliness and signal variability. Classification models need periodic adaptation for real-life use, making an optimal re-training strategy essential to maximize user acceptance and maintain high performance. We propose TOR, a train-on-request workflow that enables user-specific model adaptation to novel conditions, addressing signal variability over time. Using continual learning, TOR preserves knowledge across sessions and mitigates inter-session variability. With TOR, users can refine, on demand, the model through on-device learning (ODL) to enhance accuracy adapting to changing conditions. We evaluate the proposed methodology on a motor-movement dataset recorded with a non-stigmatizing wearable BMI headband, achieving up to 92% accuracy and a re-calibration time as low as 1.6 minutes, a 46% reduction compared to a naive transfer learning workflow. We additionally demonstrate that TOR is suitable for ODL in extreme edge settings by deploying the training procedure on a RISC-V ultra-low-power SoC (GAP9), resulting in 21.6 ms of latency and 1 mJ of energy consumption per training step. To the best of our knowledge, this work is the first demonstration of an online, energy-efficient, dynamic adaptation of a BMI model to the intrinsic variability of EEG signals in real-time settings.

eess.SP

An Ultra-Low Power Wearable BMI System with Continual Learning Capabilities

Driven by the progress in efficient embedded processing, there is an accelerating trend toward running machine learning models directly on wearable Brain-Machine Interfaces (BMIs) to improve portability and privacy and maximize battery life. However, achieving low latency and high classification performance remains challenging due to the inherent variability of electroencephalographic (EEG) signals across sessions and the limited onboard resources. This work proposes a comprehensive BMI workflow based on a CNN-based Continual Learning (CL) framework, allowing the system to adapt to inter-session changes. The workflow is deployed on a wearable, parallel ultra-low power BMI platform (BioGAP). Our results based on two in-house datasets, Dataset A and Dataset B, show that the CL workflow improves average accuracy by up to 30.36% and 10.17%, respectively. Furthermore, when implementing the continual learning on a Parallel Ultra-Low Power (PULP) microcontroller (GAP9), it achieves an energy consumption as low as 0.45mJ per inference and an adaptation time of only 21.5ms, yielding around 25h of battery life with a small 100mAh, 3.7V battery on BioGAP. Our setup, coupled with the compact CNN model and on-device CL capabilities, meets users' needs for improved privacy, reduced latency, and enhanced inter-session performance, offering good promise for smart embedded real-world BMIs.

eess.SP

BISeizuRe: BERT-Inspired Seizure Data Representation to Improve Epilepsy Monitoring

This study presents a novel approach for EEG-based seizure detection leveraging a BERT-based model. The model, BENDR, undergoes a two-phase training process. Initially, it is pre-trained on the extensive Temple University Hospital EEG Corpus (TUEG), a 1.5 TB dataset comprising over 10,000 subjects, to extract common EEG data patterns. Subsequently, the model is fine-tuned on the CHB-MIT Scalp EEG Database, consisting of 664 EEG recordings from 24 pediatric patients, of which 198 contain seizure events. Key contributions include optimizing fine-tuning on the CHB-MIT dataset, where the impact of model architecture, pre-processing, and post-processing techniques are thoroughly examined to enhance sensitivity and reduce false positives per hour (FP/h). We also explored custom training strategies to ascertain the most effective setup. The model undergoes a novel second pre-training phase before subject-specific fine-tuning, enhancing its generalization capabilities. The optimized model demonstrates substantial performance enhancements, achieving as low as 0.23 FP/h, 2.5$\times$ lower than the baseline model, with a lower but still acceptable sensitivity rate, showcasing the effectiveness of applying a BERT-based approach on EEG-based seizure detection.

cs.LG

12 mJ per Class On-Device Online Few-Shot Class-Incremental Learning

Few-Shot Class-Incremental Learning (FSCIL) enables machine learning systems to expand their inference capabilities to new classes using only a few labeled examples, without forgetting the previously learned classes. Classical backpropagation-based learning and its variants are often unsuitable for battery-powered, memory-constrained systems at the extreme edge. In this work, we introduce Online Few-Shot Class-Incremental Learning (O-FSCIL), based on a lightweight model consisting of a pretrained and metalearned feature extractor and an expandable explicit memory storing the class prototypes. The architecture is pretrained with a novel feature orthogonality regularization and metalearned with a multi-margin loss. For learning a new class, our approach extends the explicit memory with novel class prototypes, while the remaining architecture is kept frozen. This allows learning previously unseen classes based on only a few examples with one single pass (hence online). O-FSCIL obtains an average accuracy of 68.62% on the FSCIL CIFAR100 benchmark, achieving state-of-the-art results. Tailored for ultra-low-power platforms, we implement O-FSCIL on the 60 mW GAP9 microcontroller, demonstrating online learning capabilities within just 12 mJ per new class.

cs.LG

SzCORE: A Seizure Community Open-source Research Evaluation framework for the validation of EEG-based automated seizure detection algorithms

The need for high-quality automated seizure detection algorithms based on electroencephalography (EEG) becomes ever more pressing with the increasing use of ambulatory and long-term EEG monitoring. Heterogeneity in validation methods of these algorithms influences the reported results and makes comprehensive evaluation and comparison challenging. This heterogeneity concerns in particular the choice of datasets, evaluation methodologies, and performance metrics. In this paper, we propose a unified framework designed to establish standardization in the validation of EEG-based seizure detection algorithms. Based on existing guidelines and recommendations, the framework introduces a set of recommendations and standards related to datasets, file formats, EEG data input content, seizure annotation input and output, cross-validation strategies, and performance metrics. We also propose the 10-20 seizure detection benchmark, a machine-learning benchmark based on public datasets converted to a standardized format. This benchmark defines the machine-learning task as well as reporting metrics. We illustrate the use of the benchmark by evaluating a set of existing seizure detection algorithms. The SzCORE (Seizure Community Open-source Research Evaluation) framework and benchmark are made publicly available along with an open-source software library to facilitate research use, while enabling rigorous evaluation of the clinical significance of the algorithms, fostering a collective effort to more optimally detect seizures to improve the lives of people with epilepsy.

eess.SP

Skilog: A Smart Sensor System for Performance Analysis and Biofeedback in Ski Jumping

In ski jumping, low repetition rates of jumps limit the effectiveness of training. Thus, increasing learning rate within every single jump is key to success. A critical element of athlete training is motor learning, which has been shown to be accelerated by feedback methods. In particular, a fine-grained control of the center of gravity in the in-run is essential. This is because the actual takeoff occurs within a blink of an eye ($\sim$300ms), thus any unbalanced body posture during the in-run will affect flight. This paper presents a smart, compact, and energy-efficient wireless sensor system for real-time performance analysis and biofeedback during ski jumping. The system operates by gauging foot pressures at three distinct points on the insoles of the ski boot at 100Hz. Foot pressure data can either be directly sent to coaches to improve their feedback, or fed into a ML model to give athletes instantaneous in-action feedback using a vibration motor in the ski boot. In the biofeedback scenario, foot pressures act as input variables for an optimized XGBoost model. We achieve a high predictive accuracy of 92.7% for center of mass predictions (dorsal shift, neutral stand, ventral shift). Subsequently, we parallelized and fine-tuned our XGBoost model for a RISC-V based low power parallel processor (GAP9), based on the PULP architecture. We demonstrate real-time detection and feedback (0.0109ms/inference) using our on-chip deployment. The proposed smart system is unobtrusive with a slim form factor (13mm baseboard, 3.2mm antenna) and a lightweight build (26g). Power consumption analysis reveals that the system's energy-efficient design enables sustained operation over multiple days (up to 300 hours) without requiring recharge.

eess.SP