SearcharxivSearch

arXiv subjects

Tianfang Li

Publications and source records attributed to Tianfang Li.

2 recordsLinked to original sources

Spatiotemporal Gaussian Optimization for 4D Cone Beam CT Reconstruction from Sparse Projections

In image-guided radiotherapy (IGRT), four-dimensional cone-beam computed tomography (4D-CBCT) is critical for assessing tumor motion during a patients breathing cycle prior to beam delivery. However, generating 4D-CBCT images with sufficient quality requires significantly more projection images than a standard 3D-CBCT scan, leading to extended scanning times and increased imaging dose to the patient. To address these limitations, there is a strong demand for methods capable of reconstructing high-quality 4D-CBCT images from a 1-minute 3D-CBCT acquisition. The challenge lies in the sparse sampling of projections, which introduces severe streaking artifacts and compromises image quality. This paper introduces a novel framework leveraging spatiotemporal Gaussian representation for 4D-CBCT reconstruction from sparse projections, achieving a balance between streak artifact reduction, dynamic motion preservation, and fine detail restoration. Each Gaussian is characterized by its 3D position, covariance, rotation, and density. Two-dimensional X-ray projection images can be rendered from the Gaussian point cloud representation via X-ray rasterization. The properties of each Gaussian were optimized by minimizing the discrepancy between the measured projections and the rendered X-ray projections. A Gaussian deformation network is jointly optimized to deform these Gaussian properties to obtain a 4D Gaussian representation for dynamic CBCT scene modeling. The final 4D-CBCT images are reconstructed by voxelizing the 4D Gaussians, achieving a high-quality representation that preserves both motion dynamics and spatial detail. The code and reconstruction results can be found at https://github.com/fuyabo/4DGS_for_4DCBCT/tree/main

physics.med-ph

Generalizable Cone Beam CT Esophagus Segmentation Using Physics-Based Data Augmentation

Automated segmentation of esophagus is critical in image guided/adaptive radiotherapy of lung cancer to minimize radiation-induced toxicities such as acute esophagitis. We developed a semantic physics-based data augmentation method for segmenting esophagus in both planning CT (pCT) and cone-beam CT (CBCT) using 3D convolutional neural networks. 191 cases with their pCT and CBCTs from four independent datasets were used to train a modified 3D-Unet architecture with a multi-objective loss function specifically designed for soft-tissue organs such as esophagus. Scatter artifacts and noise were extracted from week 1 CBCTs using power law adaptive histogram equalization method and induced to the corresponding pCT followed by reconstruction using CBCT reconstruction parameters. Moreover, we leverage physics-based artifact induced pCTs to drive the esophagus segmentation in real weekly CBCTs. Segmentations were evaluated using geometric Dice and Hausdorff distance as well as dosimetrically using mean esophagus dose and D5cc. Due to the physics-based data augmentation, our model trained just on the synthetic CBCTs was robust and generalizable enough to also produce state-of-the-art results on the pCTs and CBCTs, achieving 0.81 and 0.74 Dice overlap. Our physics-based data augmentation spans the realistic noise/artifact spectrum across patient CBCT/pCT data and can generalize well across modalities with the potential to improve the accuracy of treatment setup and response analysis.

eess.IV