SearcharxivSearch

arXiv subjects

Tianling Lv

Publications and source records attributed to Tianling Lv.

2 recordsLinked to original sources

Stationary Multi-source AI-powered Real-time Tomography (SMART)

Over the past decades, the development of CT technologies has been largely driven by the needs for cardiac imaging but the temporal resolution remains insufficient for clinical CT in difficult cases and rather challenging for preclinical micro-CT since small animals, as human cardiac disease models, have much higher heart rates than human. To address this challenge, here we report a Stationary Multi-source AI-based Real-time Tomography (SMART) micro-CT system. This unique scanner is featured by 29 source-detector pairs fixed on a circular track to collect x-ray signals in parallel, enabling instantaneous tomography in principle. Given the multi-source architecture, the field-of-view only covers a cardiac region. To solve this interior problem, an AI-empowered interior tomography approach is developed to synergize sparsity-based regularization and learning-based reconstruction. To demonstrate the performance and utilities of the SMART system, extensive results are obtained in physical phantom experiments and animal studies, including dead and live rats as well as live rabbits. The reconstructed volumetric images convincingly demonstrate the merits of the SMART system using the AI-empowered interior tomography approach, enabling cardiac micro-CT with the unprecedented temporal resolution of 30ms, which is an order of magnitude higher than the state of the art.

q-bio.QM

Dual-energy CT imaging using a single-energy CT data is feasible via deep learning

In a standard computed tomography (CT) image, pixels having the same Hounsfield Units (HU) can correspond to different materials and it is, therefore, challenging to differentiate and quantify materials. Dual-energy CT (DECT) is desirable to differentiate multiple materials, but DECT scanners are not widely available as single-energy CT (SECT) scanners. Here we develop a deep learning approach to perform DECT imaging by using standard SECT data. A deep learning model to map low-energy image to high-energy image using a two-stage convolutional neural network (CNN) is developed. The model was evaluated using patients who received contrast-enhanced abdomen DECT scan with a popular DE application: virtual non-contrast (VNC) imaging and contrast quantification. The HU differences between the predicted and original high-energy CT images are 3.47, 2.95, 2.38 and 2.40 HU for ROIs on the spine, aorta, liver, and stomach, respectively. The HU differences between VNC images obtained from original DECT and deep learning DECT are 4.10, 3.75, 2.33 and 2.92 HU for the 4 ROIs, respectively. The aorta iodine quantification difference between iodine maps obtained from original DECT and deep learning DECT images is 0.9\%, suggesting high consistency between the predicted and the original high-energy CT images. This study demonstrates that highly accurate DECT imaging with single low-energy data is achievable by using a deep learning approach. The proposed method can significantly simplify the DECT system design, reducing the scanning dose and imaging cost.

physics.med-ph