SearcharxivSearch

arXiv subjects

Tianling Lyu

Publications and source records attributed to Tianling Lyu.

9 recordsLinked to original sources

CNsEMD: An Expert-Annotated Multi-Field-Strength MRI Dataset and a Hyperspherical Manifold Network for Multimodal Cranial Nerve Parcellation

Cranial nerves (CNs) play essential roles in sensory, motor, and autonomic functions. Accurate CN parcellation from multimodal magnetic resonance imaging (MRI) is crucial for neuroanatomical analysis and neurosurgical planning. However, accurate CN parcellation remains extremely challenging because CNs are very small, exhibit low image contrast, and have slender tubular morphologies and complex anatomical trajectories. Moreover, the lack of publicly available, expert-annotated datasets has impeded the development and fair benchmarking of learning-based CN analysis methods. In this work, we introduce CNsEMD, an expert-annotated multimodal dataset for CN parcellation. It comprises data from 202 subjects acquired on 3T, 5T, and 7T MRI scanners. We further propose the projective hyperspherical manifold network (PHM-Net), which learns cross-modal representations by capturing angular relationships in a shared hyperspherical embedding space. Rather than performing multimodal fusion in Euclidean space, the proposed Hyperspherical cross-modal interaction (HCI) module enables bidirectional feature exchange between T1-weighted (T1w) and direction-encoded color (DEC) representations on a unit hypersphere. The Magnitude-preserving projective hyperspherical orientation representation (PHOR) captures the axial nature of DEC orientations while preserving diffusion magnitude. The hyperspherical prototype segmentation head (HPSH) further extends angular similarity to voxel-wise classification using normalized voxel embeddings and learnable class prototypes. Extensive experimental results on the CNsEMD dataset demonstrate the effectiveness of our PHM-Net against state-of-the-art methods. CNsEMD establishes a reproducible benchmark for multimodal CN imaging, while PHM-Net provides a geometry-consistent solution for CN parcellation across diverse MRI acquisitions.

cs.CV

Efficient Chambolle-Pock based algorithms for Convoltional sparse representation

Recently convolutional sparse representation (CSR), as a sparse representation technique, has attracted increasing attention in the field of image processing, due to its good characteristic of translate-invariance. The content of CSR usually consists of convolutional sparse coding (CSC) and convolutional dictionary learning (CDL), and many studies focus on how to solve the corresponding optimization problems. At present, the most efficient optimization scheme for CSC is based on the alternating direction method of multipliers (ADMM). However, the ADMM-based approach involves a penalty parameter that needs to be carefully selected, and improper parameter selection may result in either no convergence or very slow convergence. In this paper, a novel fast and efficient method using Chambolle-Pock(CP) framework is proposed, which does not require extra manual selection parameters in solving processing, and has faster convergence speed. Furthermore, we propose an anisotropic total variation penalty of the coefficient maps for CSC and apply the CP algorithm to solve it. In addition, we also apply the CP framework to solve the corresponding CDL problem. Experiments show that for noise-free image the proposed CSC algorithms can achieve rival results of the latest ADMM-based approach, while outperforms in removing noise from Gaussian noise pollution image.

cs.CV

RSTAR4D: Rotational Streak Artifact Reduction in 4D CBCT using a Separable 4D CNN

Four-dimensional cone-beam computed tomography (4D CBCT) provides respiration-resolved images and can be used for image-guided radiation therapy. However, the ability to reveal respiratory motion comes at the cost of image artifacts. As raw projection data are sorted into multiple respiratory phases, the cone-beam projections become much sparser and the reconstructed 4D CBCT images will be covered by severe streak artifacts. Although several deep learning-based methods have been proposed to address this issue, most algorithms employ 2D network models as backbones, neglecting the intrinsic structural priors within 4D CBCT images. In this paper, we first explore the origin and appearance of streak artifacts in 4D CBCT images. We find that streak artifacts exhibit a unique rotational motion along with the patient's respiration, distinguishable from diaphragm-driven respiratory motion in the spatiotemporal domain. Therefore, we propose a novel 4D neural network model, RSTAR4D-Net, designed to address Rotational STreak Artifact Reduction by integrating the spatial and temporal information within 4D CBCT images. Specifically, we overcome the computational and training difficulties of a 4D neural network. The specially designed model adopts an efficient implementation of 4D convolutions to reduce computational costs and thus can process the whole 4D image in one pass. Additionally, a Tetris training strategy pertinent to the separable 4D convolutions is proposed to effectively train the model using limited 4D training samples. Extensive experiments substantiate the effectiveness of our proposed method, and the RSTAR4D-Net shows superior performance compared to other methods. The source code and dynamic demos are available at https://github.com/ivy9092111111/RSTAR.

eess.IV

CC-DCNet: Dynamic Convolutional Neural Network with Contrastive Constraints for Identifying Lung Cancer Subtypes on Multi-modality Images

The accurate diagnosis of pathological subtypes of lung cancer is of paramount importance for follow-up treatments and prognosis managements. Assessment methods utilizing deep learning technologies have introduced novel approaches for clinical diagnosis. However, the majority of existing models rely solely on single-modality image input, leading to limited diagnostic accuracy. To this end, we propose a novel deep learning network designed to accurately classify lung cancer subtype with multi-dimensional and multi-modality images, i.e., CT and pathological images. The strength of the proposed model lies in its ability to dynamically process both paired CT-pathological image sets as well as independent CT image sets, and consequently optimize the pathology-related feature extractions from CT images. This adaptive learning approach enhances the flexibility in processing multi-dimensional and multi-modality datasets and results in performance elevating in the model testing phase. We also develop a contrastive constraint module, which quantitatively maps the cross-modality associations through network training, and thereby helps to explore the "gold standard" pathological information from the corresponding CT scans. To evaluate the effectiveness, adaptability, and generalization ability of our model, we conducted extensive experiments on a large-scale multi-center dataset and compared our model with a series of state-of-the-art classification models. The experimental results demonstrated the superiority of our model for lung cancer subtype classification, showcasing significant improvements in accuracy metrics such as ACC, AUC, and F1-score.

eess.IV

Full-length-body CBCT imaging in upright position with robotic-arm system: a simulation study

Upright position CT scans make it possible for full-length-body imaging at conditions more relevant to daily situations, but the substantial weight of the upright CT scanners increases the risks to floor's stability and patients'safety. Robotic-arm CBCT systems are supposed to be a better solution for this task, but such systems still face challenges including long scanning time and low reconstruction quality. To address the above challenges, this paper proposes a novel method to calculate optimal scanning pitch based on data completeness analysis, which can complete the whole-body scan in the shortest time without a significant decline in image quality. Besides, an FDK-style reconstruction method based on normalized projections is proposed to obtain fast image reconstruction. Extensive experiments prove the effectiveness of the proposed optimal scanning trajectory. Qualitative and quantitative comparisons with FDK and iterative algorithms show that the proposed reconstruction method can obtain high imaging quality with reasonable computation costs. The method proposed in this paper is expected to promote the application of robotic-arm CBCT systems in orthopedic functional analysis.

physics.med-ph

PDS-MAR: a fine-grained Projection-Domain Segmentation-based Metal Artifact Reduction method for intraoperative CBCT images with guidewires

Since the invention of modern CT systems, metal artifacts have been a persistent problem. Due to increased scattering, amplified noise, and insufficient data collection, it is more difficult to suppress metal artifacts in cone-beam CT, limiting its use in human- and robot-assisted spine surgeries where metallic guidewires and screws are commonly used. In this paper, we demonstrate that conventional image-domain segmentation-based MAR methods are unable to eliminate metal artifacts for intraoperative CBCT images with guidewires. To solve this problem, we present a fine-grained projection-domain segmentation-based MAR method termed PDS-MAR, in which metal traces are augmented and segmented in the projection domain before being inpainted using triangular interpolation. In addition, a metal reconstruction phase is proposed to restore metal areas in the image domain. The digital phantom study and real CBCT data study demonstrate that the proposed algorithm achieves significantly better artifact suppression than other comparing methods and has the potential to advance the use of intraoperative CBCT imaging in clinical spine surgeries.

physics.med-ph

Dual-energy Computed Tomography Imaging from Contrast-enhanced Single-energy Computed Tomography

In a standard computed tomography (CT) image, pixels having the same Hounsfield Units (HU) can correspond to different materials and it is therefore challenging to differentiate and quantify materials. Dual-energy CT (DECT) is desirable to differentiate multiple materials, but DECT scanners are not widely available as single-energy CT (SECT) scanners. Here we purpose a deep learning approach to perform DECT imaging by using standard SECT data. We designed a predenoising and difference learning mechanism to generate DECT images from SECT data. The performance of the deep learning-based DECT approach was studied using images from patients who received contrast-enhanced abdomen DECT scan with a popular DE application: virtual non-contrast (VNC) imaging and contrast quantification. Clinically relevant metrics were used for quantitative assessment. The absolute HU difference between the predicted and original high-energy CT images are 1.3 HU, 1.6 HU, 1.8 HU and 1.3 HU for the ROIs on aorta, liver, spine and stomach, respectively. The aorta iodine quantification difference between iodine maps obtained from the original and deep learning DECT images is smaller than 1.0\%, and the noise levels in the material images have been reduced by more than 7-folds for the latter. This study demonstrates that highly accurate DECT imaging with single low-energy data is achievable by using a deep learning approach. The proposed method allows us to obtain high-quality DECT images without paying the overhead of conventional hardware-based DECT solutions and thus leads to a new paradigm of spectral CT imaging.

physics.med-ph

Dual-energy CT imaging from single-energy CT data with material decomposition convolutional neural network

Dual-energy computed tomography (DECT) is of great significance for clinical practice due to its huge potential to provide material-specific information. However, DECT scanners are usually more expensive than standard single-energy CT (SECT) scanners and thus are less accessible to undeveloped regions. In this paper, we show that the energy-domain correlation and anatomical consistency between standard DECT images can be harnessed by a deep learning model to provide high-performance DECT imaging from fully-sampled low-energy data together with single-view high-energy data, which can be obtained by using a scout-view high-energy image. We demonstrate the feasibility of the approach with contrast-enhanced DECT scans from 5,753 slices of images of twenty-two patients and show its superior performance on DECT applications. The deep learning-based approach could be useful to further significantly reduce the radiation dose of current premium DECT scanners and has the potential to simplify the hardware of DECT imaging systems and to enable DECT imaging using standard SECT scanners.

physics.med-ph

A deep learning approach for virtual monochromatic spectral CT imaging with a standard single energy CT scanner

Purpose/Objectives: To develop and assess a strategy of using deep learning (DL) to generate virtual monochromatic CT (VMCT) images from a single-energy CT (SECT) scan. Materials/Methods: The proposed data-driven VMCT imaging consists of two steps: (i) using a supervised DL model trained with a large number of 100 kV and 140 kV dual-energy CT (DECT) image pairs to produce the corresponding high-energy CT image from a low-energy image; and (ii) reconstructing VMCT images with energy ranging from 40 to 150 keV. To evaluate the performance of the method, we retrospectively studied 6,767 abdominal DECT images. The VMCT images reconstructed using both DL-derived DECT (DL-DECT) images and the images from DECT scanner were compared quantitatively. Paired-sample t-tests were used for statistical analysis to show the consistency and precision of calculated HU values. Results: Excellent agreement was found between the DL-DECT and the ground truth DECT images (p values ranged from 0.50 to 0.95). Noise reduction up to 68% (from 163 HU to 51 HU) was achieved for DL-based VMCT imaging as compared to that obtained by using the standard DECT. For the DL-based VMCT, the maximum iodine contrast-to-noise ratio (CNR) for each patient (ranging from 15.1 to 16.6) was achieved at 40 keV. In addition to the enormous benefit of VMCT acquisition with merely a SECT image, an improvement of CNR as high as 55% (from 10.7 to 16.6) was attained with the proposed approach. Conclusions: This study demonstrates that high-quality VMCT images can be obtained with only a SECT scan.

physics.med-ph