Simulation Study of the Design and Spatial Resolution of a Novel AC-coupled Cross Strip LGAD

AC-coupled Low Gain Avalanche Diode (AC-LGAD), evolved from the standard LGAD technology, are silicon detectors characterized by exceptional temporal and spatial resolutions. This work proposes a novel sensor named AC-coupled Cross Strip LGAD (CS-LGAD) structure with dual-layered overlapping strip electrodes. It can achieve two-dimensional particle position measurement with low readout density while also inheriting the high temporal resolution of the LGAD. The sensor structure, doping and current-voltage (I-V) characteristics of the sensor were investigated through TCAD simulations. Additionally, Monte Carlo simulations were employed to simulate the signal response of CS-LGAD to minimum ionizing particles (MIPs). The response of MIPs hitting different positions was simulated, and the reconstruction of particle coordinates (x and y) was achieved based on the sharing of charges on the dual-layer electrodes. The spatial resolution might reach 3.6% and 5.5% of the pitch size in the x and y directions, respectively, according to the simulation. The proposed CS-LGAD is a promising 4D detector with low mass and low readout density.

physics.ins-det

Beam test result and digitization of TaichuPix-3: A Monolithic Active Pixel Sensors for CEPC vertex detector

The Circular Electron-Positron Collider (CEPC), as the next-generation electron-positron collider, is tasked with advancing not only Higgs physics but also the discovery of new physics. Achieving these goals requires high-precision measurements of particles. Taichu seires, Monolithic Active Pixel Sensor (MAPS), a key component of the vertex detector for CEPC was designed to meet the CEPC's requirements. For the geometry of vertex detector is long barrel with no endcap, and current silicon lacks a complete digitization model, precise estimation of cluster size particularly causing by particle with large incident angle is needed. Testbeam results were conducted at the Beijing Synchrotron Radiation Facility (BSRF) to evaluate cluster size dependence on different incident angles and threshold settings. Experimental results confirmed that cluster size increases with incident angle. Simulations using the Allpix$^2$ framework replicated experimental trends at small angles but exhibited discrepancies at large angles, suggesting limitations in linear electric field assumptions and sensor thickness approximations. The results from both testbeam and simulations have provided insights into the performance of the TaichuPix chip at large incident angles, offering a crucial foundation for the establishment of a digital model and addressing the estimation of cluster size in the forward region of the long barrel. Furthermore, it offers valuable references for future iterations of TaichuPix, the development of digital models, and the simulation and estimation of the vertex detector's performance.

physics.ins-det

The Performance of AC-coupled Strip LGAD developed by IHEP

The AC-coupled Strip LGAD (Strip AC-LGAD) is a novel LGAD design that diminishes the density of readout electronics through the use of strip electrodes, enabling the simultaneous measurement of time and spatial information. The Institute of High Energy Physics has designed a long Strip AC-LGAD prototype with a strip electrode length of 5.7 mm and pitches of 150 $μm$, 200 $μm$, and 250 $μm$. Spatial and timing resolutions of the long Strip AC-LGAD are studied by pico-second laser test and beta source tests. The laser test demonstrates that spatial resolution improves as the pitch size decreases, with an optimal resolution achieved at 8.3 $μ$m. Furthermore, the Beta source test yields a timing resolution of 37.6 ps.

physics.ins-det

Beam test of a baseline vertex detector prototype for CEPC

The Circular Electron Positron Collider (CEPC) has been proposed to enable more thorough and precise measurements of the properties of Higgs, W, and Z bosons, as well as to search for new physics. In response to the stringent performance requirements of the vertex detector for the CEPC, a baseline vertex detector prototype was tested and characterized for the first time using a 6 GeV electron beam at DESY II Test Beam Line 21. The baseline vertex detector prototype is designed with a cylindrical barrel structure that contains six double-sided detector modules (ladders). Each side of the ladder includes TaichuPix-3 sensors based on Monolithic Active Pixel Sensor (MAPS) technology, a flexible printed circuit, and a carbon fiber support structure. Additionally, the readout electronics and the Data Acquisition system were also examined during this beam test. The performance of the prototype was evaluated using an electron beam that passed through six ladders in a perpendicular direction. The offline data analysis indicates a spatial resolution of about 5 um, with detection efficiency exceeding 99 % and an impact parameter resolution of about 5.1 um. These promising results from this baseline vertex detector prototype mark a significant step toward realizing the optimal vertex detector for the CEPC.

physics.ins-det

Beam test of a 180 nm CMOS Pixel Sensor for the CEPC vertex detector

The proposed Circular Electron Positron Collider (CEPC) imposes new challenges for the vertex detector in terms of pixel size and material budget. A Monolithic Active Pixel Sensor (MAPS) prototype called TaichuPix, based on a column drain readout architecture, has been developed to address the need for high spatial resolution. In order to evaluate the performance of the TaichuPix-3 chips, a beam test was carried out at DESY II TB21 in December 2022. Meanwhile, the Data Acquisition (DAQ) for a muti-plane configuration was tested during the beam test. This work presents the characterization of the TaichuPix-3 chips with two different processes, including cluster size, spatial resolution, and detection efficiency. The analysis results indicate the spatial resolution better than 5 $μm$ and the detection efficiency exceeds 99.5 % for both TaichuPix-3 chips with the two different processes.

physics.ins-det

The performance of large-pitch AC-LGAD with different N+ dose

AC-Coupled LGAD (AC-LGAD) is a new 4D detector developed based on the Low Gain Avalanche Diode (LGAD) technology, which can accurately measure the time and spatial information of particles. The Institute of High Energy Physics (IHEP) designed a large-size AC-LGAD with a pitch of 2000~\SI{}{\micro\metre} and AC pad of 1000~\SI{}{\micro\metre}, and explored the effect of N+ layer dose on the spatial resolution and time resolution. The spatial resolution varied from 36~\SI{}{\micro\metre} to 16~\SI{}{\micro\metre} depending on N+ dose for a charge corresponding to about 12 minimum ionizing particles. The jitter component of the time resolution does not change significantly with different N+ doses, and it is about 15-17 ps measured by laser. The AC-LGAD with a low N+ dose has a large attenuation factor and better spatial resolution in the central region between pads. In these specific conditions, large signal attenuation factor and low noise level are beneficial to improve the spatial resolution of the AC-LGAD sensor.

physics.ins-det

Characterization of the response of IHEP-IME LGAD with shallow carbon to Gamma Irradiation

Low Gain Avalanche Detectors (LGAD) for the High-Granularity Timing Detector (HGTD) are crucial in reducing pileups in the High-Luminosity Large Hadron Collider. Numerous studies have been conducted on the bulk irradiation damage of LGADs. However, few studies have been carried out on the surface irradiation damage of LGAD sensors with shallow carbon implantation. In this paper, the IHEP-IME LGADs with shallow carbon implantation were irradiated up to 2 MGy using gamma irradiation to investigate surface damage. Important characteristic parameters, including leakage currents, breakdown voltage (BV), inter-pad resistances, and capacitances, were tested before and after irradiation. The results showed that the leakage current and BV increased after irradiation, whereas overall inter-pad resistance exhibited minimal change and remained above $10^9\ Ω$ before and after irradiation. Capacitance was found to be less than 4.5 pF with a slight decrease in the gain layer depletion voltage (V$_{gl}$) after irradiation. No parameter affected by the inter-pad separation was observed before and after irradiation. All characteristic parameters meet the requirements of HGTD, and this design can be used to further optimization.