SearcharxivSearch

arXiv subjects

Tillmann Buttersack

Publications and source records attributed to Tillmann Buttersack.

3 recordsLinked to original sources

Non-equilibrium state during proton-deuteron exchange at a liquid-liquid interface

Proton-deuteron exchange is a very fast process, even across macroscopic length scales. Here we directly and quantitatively measure the formation of HDO within the first 100 microseconds of the reaction at the liquid-liquid interface between D$_2$O and H$_2$O, using a fast-flowing liquid flat jet combined with infrared spectroscopic imaging. We demonstrate that, at early stages HDO formation is reaction-limited, set by the low concentration of the hydroxide and hydronium ions that mediate the exchange. As the ion concentration rises, the rate rapidly approaches the diffusion limit. The reaction rate constant we extract is consistent with the picosecond timescale of the elementary proton-deuteron exchange. Access to these microsecond kinetics reveals a non-equilibrium state in the early H$_2$O/D$_2$O interface: the two liquids are fully mixed by diffusion, yet the HDO concentration remains well below equilibrium. Quantitative imaging of reactant and product concentrations at well-defined liquid-liquid interfaces, as introduced here, will enable the study of fast kinetics across a wide range of chemical reactions.

physics.chem-ph

Site- and Energy-Selective Low-Energy Electron Emission by X-Rays in Aqueous Phase

Low-energy-electron emission from resonant Auger final states via intermolecular Coulombic decay (RA-ICD) has been previously described as a promising scenario for controlling radiation damage for medical purposes, but has so far only been observed in prototypical atomic and molecular van der Waals dimers and clusters. Here, we report the experimental observation of RA-ICD in aqueous solution. We show that for solvated Ca$^{2+}$ ions, the emission can be very efficiently controlled by tuning the photon energy of exciting X-rays to inner-shell resonances of the ions. Our results provide the next step from proving RA-ICD in relatively simple prototype systems to understanding the relevance and potential applications of ICD in real-life scenarios.

physics.chem-ph

Imaging Temperature and Thickness of Thin Planar Liquid Water Jets in Vacuum

We present spatially resolved measurements of the temperature of a flat liquid water microjet for varying pressures, from vacuum to 100% relative humidity. The entire jet surface is probed in a single shot by a high-resolution infrared camera. Obtained 2D images are substantially influenced by the temperature of the apparatus on the opposite side of the IR camera; a protocol to correct for the thermal background radiation is presented. In vacuum, we observe cooling rates due to water evaporation on the order of 105 K/s. For our system, this corresponds to a temperature decrease of approximately 15 K between upstream and downstream positions of the flowing leaf. Making reasonable assumptions on the absorption of the thermal background radiation in the flatjet we can extend our analysis to infer a thickness map. For a reference system our value for the thickness is in good agreement with the one reported from white light interferometry.

cond-mat.soft