SearcharxivSearch

arXiv subjects

Timothy M Spicer

Publications and source records attributed to Timothy M Spicer.

2 recordsLinked to original sources

Spatial Mapping of Torques within a Spin Hall Nano-oscillator

Time-resolved scanning Kerr microscopy (TRSKM) was used to study precessional magnetization dynamics induced by a radio frequency (RF) current within a Al$_2$O$_3$/Py(5 nm)/Pt(6 nm)/Au(150 nm) spin Hall nano-oscillator structure. The Au layer was formed into two needle-shaped electrical contacts that concentrated the current in the centre of a Py/Pt mesa of 4 $μ$m diameter. Due to the spin Hall effect, current within the Pt layer drives a spin current into the Py layer, exerting a spin transfer torque (STT). By injecting RF current, and exploiting the phase-sensitivity of TRSKM and the symmetry of the device structure, the STT and Oersted field torques have been separated and spatially mapped. The STT and torque due to the in-plane Oersted field are observed to exhibit minima at the device centre that is ascribed to spreading of RF current that is not observed for DC current. Torques associated with the RF current may destabilise the position of the self-localised bullet mode excited by the DC current, and inhibit injection locking. The present study demonstrates the need to characterise both DC and RF current distributions carefully.

cond-mat.mes-hall

Time resolved imaging of the non-linear bullet mode within an injection-locked nano-contact spin Hall nano-oscillator

Injection of a radio frequency (RF) current was used to phase lock the SHNO to the TRSKM. The out of plane magnetization was detected by means of the polar magneto optical Kerr effect (MOKE). However, longitudinal MOKE images were dominated by an artifact arising from the edges of the Au NCs. Time resolved imaging revealed the simultaneous excitation of a non-linear `bullet' mode at the centre of the device, once the DC current exceeded a threshold value, and ferromagnetic resonance (FMR) induced by the RF current. However, the FMR response observed for sub-critical DC current values exhibits an amplitude minimum at the centre, which is attributed to spreading of the RF spin current due to the reactance of the device structure. This FMR response can be subtracted to yield images of the bullet mode. As the DC current is increased above threshold, the bullet mode appears to increase in size, suggesting increased translational motion. The reduced spatial overlap of the bullet and FMR modes, and this putative translational motion, may impede the injection locking and contribute to the reduced locking range observed within NC-SHNO devices. This illustrates a more general need to control the geometry of an injection-locked oscillator so that the autonomous dynamics of the oscillator exhibit strong spatial overlap with those resulting from the injected signal.

cond-mat.mes-hall