OpenMRF: A Modular, Vendor-Neutral Open-Source Framework for Reproducible Magnetic Resonance Fingerprinting using Pulseq

Purpose: Widespread adoption and methodological advancement of Magnetic Resonance Fingerprinting (MRF) are limited by the lack of unified, reproducible implementation frameworks and fragmented open-source tools. To address these barriers, we introduce OpenMRF - a comprehensive Pulseq-based solution - designed to enable consistent, reproducible, and transferable MRF research across vendors, sites, and field strengths. Methods: OpenMRF integrates modular Pulseq-based sequence design, Bloch-simulation-based dictionary creation directly from .seq files, and iterative low-rank subspace reconstruction. The framework was evaluated through digital phantom simulations, a multi-site ISMRM/NIST phantom study on Siemens MRI systems at 0.55 T, 1.5 T, and 3 T as well as GE and United Imaging 3 T platforms, and representative in vivo acquisitions in the liver (0.55 T), myocardium (1.5 T), and brain (3 T). Results: Simulations demonstrated high mapping accuracy in an ISMRM/NIST-like digital phantom, with low-rank reconstruction yielding deviations of 0.03+/-0.32 % (T1) and 0.12+/-1.94 % (T2). The multi-site phantom study yielded relaxation times consistent with reference values at all field strengths, with mean deviations of -0.1+/-2.9 % (T1), -1.5+/-8.7 % (T2), and -4.0+/-7.2 % (T1rho). In vivo acquisitions produced high-quality parameter maps across platforms and field strengths. Conclusion: OpenMRF provides a robust, open-source, end-to-end Pulseq-based solution for MRF that enables reproducible sequence implementation, physics-accurate dictionary simulation, and advanced reconstruction across vendors and field strengths. By providing a unified platform for method development, comparison, and multi-site validation, OpenMRF aims to accelerate reproducible and harmonized quantitative MRI research within the community.

physics.med-ph

Fast MRI of bones in the knee -- An AI-driven reconstruction approach for adiabatic inversion recovery prepared ultra-short echo time sequences

Purpose: Inversion recovery prepared ultra-short echo time (IR-UTE)-based MRI enables radiation-free visualization of osseous tissue. However, sufficient signal-to-noise ratio (SNR) can only be obtained with long acquisition times. This study proposes a data-driven approach to reconstruct undersampled IR-UTE knee data, thereby accelerating MR-based 3D imaging of bones. Methods: Data were acquired with a 3D radial IR-UTE pulse sequence, implemented using the open-source framework Pulseq. A denoising convolutional neural network (DnCNN) was trained in a supervised fashion using data from eight healthy subjects. Conjugate gradient sensitivity encoding (CG-SENSE) reconstructions of different retrospectively undersampled subsets (corresponding to 2.5-min, 5-min and 10-min acquisition times) were paired with the respective reference dataset reconstruction (30-min acquisition time). The DnCNN was then integrated into a Landweber-based reconstruction algorithm, enabling physics-based iterative reconstruction. Quantitative evaluations of the approach were performed using one prospectively accelerated scan as well as retrospectively undersampled datasets from four additional healthy subjects, by assessing the structural similarity index measure (SSIM), the peak signal-to-noise ratio (PSNR), the normalized root mean squared error (NRMSE), and the perceptual sharpness index (PSI). Results: Both the reconstructions of prospective and retrospective acquisitions showed good agreement with the reference dataset, indicating high image quality, particularly for an acquisition time of 5 min. The proposed method effectively preserves contrast and structural details while suppressing noise, albeit with a slight reduction in sharpness. Conclusion: The proposed method is poised to enable MR-based bone assessment in the knee within clinically feasible scan times.

physics.med-ph

Real-time cardiac cine MRI -- A comparison of a diffusion probabilistic model with alternative state-of-the-art image reconstruction techniques for undersampled spiral acquisitions

ECG-gated cine imaging in breath-hold enables high-quality diagnostics in most patients, arrhythmia and inability to hold breath, however, can severely corrupt outcomes. Real-time cardiac MRI in free-breathing leverages robust and faster investigations regardless of these confounding factors. With the need for sufficient acceleration, adequate reconstruction methods, which transfer data into high quality images, are required. Undersampled spiral real-time acquisitions in free-breathing were conducted in a study with 16 healthy volunteers and 5 patients. Image reconstructions were performed using a novel score-based diffusion model, as well as a variational network and different compressed sensing approaches. The techniques were compared by means of an expert reader study, by calculating scalar metrics and difference images with respect to a segmented reference, and by a Bland-Altman analysis of cardiac functional parameters. In participants with irregular RR-cycles, spiral real-time acquisitions showed superior image quality with respect to the clinical reference standard. Reconstructions using the diffusion model, the variational network and l1-wavelets offered an overall comparable image quality, however sharpness was slightly increased by the diffusion approach. While slightly larger ejection fractions for the real-time acquisitions were exhibited with a bias of 1.6% for healthy subjects, differences in the data acquisition procedure resulted in uncertainties of 7.4%. The proposed real-time technique enables free-breathing acquisitions of spatio-temporal images with high-quality, covering the entire heart in less than one minute. Evaluation of the ejection fractions using the segmented reference can be significantly corrupted due to arrhythmias and averaging effects. Prolonged inference times of the diffusion model represent the main obstacle to overcome for clinical translation.

physics.med-ph

Joint image reconstruction and segmentation of real-time cardiac MRI in free-breathing using a model based on disentangled representation learning

A joint image reconstruction and segmentation approach based on disentangled representation learning was trained to enable cardiac cine MR imaging in real-time and under free-breathing. An exploratory feasibility study tested the proposed method in undersampled real-time acquisitions based on an in-house developed spiral bSSFP pulse sequence in eight healthy participants and five patients with intermittent atrial fibrillation. Images and predicted LV segmentations were compared to the reference standard of ECG-gated segmented Cartesian cine in repeated breath-holds and corresponding manual segmentation. On a 5-point Likert scale, image quality of the real-time breath-hold approach and Cartesian cine was comparable in healthy participants (RT-BH: 1.99 $\pm$ .98, Cartesian: 1.94 $\pm$ .86, p=.052), but slightly inferior in free-breathing (RT-FB: 2.40 $\pm$ .98, p<.001). In patients with arrhythmia, image quality from both real-time approaches was favourable (RT-BH: 2.10 $\pm$ 1.28, p<.001, RT-FB: 2.40 $\pm$ 1.13, p<.001, Cartesian: 2.68 $\pm$ 1.13). Intra-observer reliability was good (ICC=.77, 95%-confidence interval [.75, .79], p<.001). In functional analysis, a positive bias was observed for ejection fractions derived from the proposed model compared to the clinical reference standard (RT-BH mean EF: 58.5 $\pm$ 5.6%, bias: +3.47%, 95%-confidence interval [-.86, 7.79%], RT-FB mean: 57.9 $\pm$ 10.6%, bias: +1.45%, [-3.02, 5.91%], Cartesian mean: 54.9 $\pm$ 6.7%). The introduced real-time MR imaging technique is capable of acquiring high-quality cardiac cine data in 1-2 minutes without the need for ECG gating and breath-holds. It thus offers a promising alternative to the current clinical practice of segmented acquisition, with shorter scan times, higher patient comfort and increased robustness to arrhythmia and patient incompliance.

eess.IV

Phantom-based gradient waveform measurements with compensated variable-prephasing: Description and application to EPI at 7T

Purpose: Introducing "compensated variable-prephasing" (CVP), a phantom-based method for gradient waveform measurements. The technique is based on the "variable-prephasing" (VP) method, but takes into account the effects of all gradients involved in the measurement. Methods: We conducted measurements of a trapezoidal test gradient, and of an EPI readout gradient train with three approaches: VP, CVP, and "fully compensated variable-prephasing" (FCVP). We compared them to one another and to predictions based on the gradient system transfer function. Furthermore, we used the measured and predicted EPI gradients for trajectory corrections in phantom images on a 7T scanner. Results: The VP gradient measurements are confounded by lingering oscillations of the prephasing gradients, which are compensated in the CVP and FCVP measurements. FCVP is vulnerable to a sign asymmetry in the gradient chain. However, the trajectories determined by all three methods resulted in comparably high EPI image quality. Conclusion: We present a new approach allowing for phantom-based gradient waveform measurements with high precision, which can be useful for trajectory corrections in non-Cartesian or single-shot imaging techniques. In our experimental setup, the proposed "compensated variable-prephasing" method provided the most reliable gradient measurements of the different techniques we compared.

physics.med-ph