SearcharxivSearch

arXiv subjects

Tobias Weilbach

Publications and source records attributed to Tobias Weilbach.

3 recordsLinked to original sources

High-Power Polarization-Controlled Attosecond-Scale Soft X-ray Pulses

We demonstrate a versatile platform for high-power attosecond soft X-ray pulse generation with polarization and photon energy control at the SwissFEL free-electron laser. An isolated high-current spike embedded within a long electron-beam pedestal emits soft X-ray pulses with single-spike spectra and multi-electronvolt bandwidths in the tunable magnetic fields of Apple-X undulators. Demonstrated pulse parameters include a photon energy range of 450--1070 eV, circular as well as linear polarization, and pulse energies from tens to above hundred microjoules. By tuning the longitudinal slice-dependent transverse electron beam orbit we can rapidly switch between attosecond and few femtosecond pulse length. By exploiting magnetic chicanes in the undulator line we can produce two-colour pulse pairs with tunable delay or increase the pulse energy beyond 200~\textmu J through multi-stage amplification schemes. High-resolution longitudinal phase-space measurements and start-to-end simulations in addition to spectral measurements provide consistent evidence for attosecond-scale pulse durations. This unique combination of high pulse energy and polarization control of attosecond-scale soft X-ray pulses enables the element-specific investigations of spin and chiral dynamics on the natural time scale of electron motion.

physics.acc-ph

Analysis of photoinjector transverse phase space in action and phase coordinates

Photoinjectors are the main high brightness electron sources for X-ray free electron lasers (XFEL). Photoinjector emittance reduction is one of the key knobs for improving XFEL lasing, so precise emittance measurement is critical. It's well known that rms emittance is very sensitive to low intensity tails of particle distributions in the phase space, whose measurement depend on the signal to noise ratio (SNR) and image processing procedures. Such sensitivities make the interpretations of beam transverse brightness challenging, leading to different emittance definitions to reduce the impact of tail particles. In this paper, transverse phase space is analyzed in action and phase coordinates for both analytical models and experiments, which give a more intuitive way to calculate the beam core brightness.

physics.acc-ph

Slice energy spread measurement in the low energy photoinjector

Slice energy spread is one of the key parameters in free electron laser optimizations, but its accurate measurement is not straightforward. Two recent studies from high energy ($>$100 MeV) photoinjectors at SwissFEL and European XFEL have reported much higher slice energy spread than expected at their XFEL working points (200 - 250 pC). In this paper, a new method for measuring slice energy spread at a lower beam energy ($\sim$20 MeV) is proposed and demonstrated at the PhotoInjector Test facility at DESY Zeuthen (PITZ), and the results for 250 pC and 500 pC are much lower than those measured at high energy injectors.

physics.acc-ph