SearcharxivSearch

arXiv subjects

Todd Kozlowski

Publications and source records attributed to Todd Kozlowski.

6 recordsLinked to original sources

Absolute Length Sensing in a Long-Baseline, High-Finesse Optical Cavity

The relative phase between two lasers in transmission of an optical cavity can be used to continuously measure its absolute length with sub-micron precision. The first laser is kept on resonance with the cavity, while a second laser is phase-locked to the first with a frequency separation equal to an integer multiple of the cavity's initial free spectral range. As the free spectral range frequency changes due to cavity length changes, the second laser detunes slightly from resonance and gains an additional phase offset in transmission of the cavity. The cavity length changes can be calibrated in terms of this phase offset. This technique is applied to a high-finesse optical cavity with a length of 123 meters, transforming it into a strainmeter with nanostrain sensitivity to long-term and transient seismic events. We report absolute length changes associated with anthropogenic noise, a distant earthquake, and the diurnal and semidiurnal earth tides.

physics.optics

Any Light Particle Searches with ALPS II: Description of the first science campaign

From February to May of 2024 the Any Light Particle Search II (ALPS II) conducted its first science campaign using the `light-shining-through-a-wall' technique to search for pseudo-Goldstone bosons that lie beyond the Standard Model of particle physics and which are inaccessible by accelerator-based experiments. The experimental setup consists of two strings of superconducting dipole magnets, each more than 100 m long, that are separated by a wall. Laser light is directed through the first magnet string and a heterodyne detection system is used to measure the electromagnetic power that traverses a wall via the conversion to and then from a bosonic field. After the wall, a high-finesse optical cavity resonantly enhances the signal power. Two searches were carried out, one with the laser polarized perpendicular to the magnetic field direction and another with its polarization state aligned parallel to the magnetic field. No evidence for the existence of new bosons was found. In its first science campaign, ALPS II reached photon-boson conversion probability sensitivities of a few $10^{-13}$. The ongoing upgrade of the optical system aims to increase this sensitivity by about four orders of magnitude.

hep-ex

Any Light Particle Searches with ALPS II: first science results

The light-shining-through-a-wall experiment ALPS II at DESY in Hamburg searched for axions and similar lightweight particles in its first science campaign from February to May 2024. No evidence for the existence of such particles was found. For pseudoscalar bosons like the axion, with masses below about 0.1 meV, we achieved a limit for the di-photon coupling strength of 1.5e-9 1/GeV at a 95% confidence level. This is more than a factor of 20 improvement compared to all previous similar experiments. We also provide limits on photon interactions for scalar, vector and tensor bosons. An achievement of this first science campaign is the demonstration of stable operation and robust calibration of the complex experiment. Currently, the optical system of ALPS II is being upgraded aiming for another two orders of magnitude sensitivity increase.

hep-ex

Demonstration of an interferometric technique for measuring vacuum magnetic birefringence with an optical cavity

Vacuum magnetic birefringence (VMB) is an effect predicted by quantum electrodynamics, in which the vacuum behaves as a non-linear optical medium and exhibit a birefringence in the presence of a magnetic field. In this work, an interferometric scheme is introduced to measure this effect for the first time by sensing the changes in the frequencies of fields stabilized to the resonances of an optical cavity. Results are presented from a prototype setup with this novel sensing technique implemented on a 19 m test cavity without a magnetic field. We propose using this scheme for a measurement of VMB with a 245 m long optical cavity and a string of 24 superconducting magnets, arranged for the ALPS II experiment. In this manuscript we examine potential sources of noise in the prototype, and project these results in terms of the sensitivity of the full-scale experiment.

physics.optics

Design and Performance of the ALPS II Regeneration Cavity

The Regeneration Cavity (RC) is a critical component of the Any Light Particle Search II (ALPS II) experiment. It increases the signal from possible axions and axion-like particles in the experiment by nearly four orders of magnitude. The total round-trip optical losses of the power circulating in the cavity must be minimized in order to maximize the resonant enhancement of the cavity, which is an important figure of merit for ALPS II. Lower optical losses also increase the cavity storage time and with the 123 meter long ALPS II RC we have demonstrated the longest storage time of a two-mirror optical cavity. We measured a storage time of $7.17 \pm 0.01$ ms, equivalent to a linewidth of 44.4 Hz and a finesse of 27,500 at a wavelength of 1064 nm.

physics.optics

Optical cavity characterization with a mode-matched heterodyne sensing scheme

We describe a technique for measuring the complex reflectivity of an optical cavity with a resonant local oscillator laser and an auxiliary probe laser, each coupled via opposite ends of the cavity. A heterodyne sensing scheme is then used to observe the phase and amplitude of the interference beat-note between the promptly reflected field and the cavity transmitted field injected through the far mirror. Since the local oscillator laser must pass through the cavity before interfering with the probe laser these measurements are not only independent of the spatial coupling of either laser to the cavity, but also obtained at the in-situ position of the cavity Eigenmode. This technique was demonstrated on a 19 m cavity to measure the individual transmissivities of each of the mirrors as well as the round trip optical losses to an accuracy of several parts per million.

physics.optics