SearcharxivSearch

arXiv subjects

Tom Meyer

Publications and source records attributed to Tom Meyer.

7 recordsLinked to original sources

Ultra-wideband MRE of the human liver and spleen for viscoelastic model identification in hepatic inflammation

Magnetic resonance elastography (MRE) is established for noninvasive assessment of liver fibrosis. Conventional abdominal MRE is typically limited to 40-60 Hz. Lower frequencies remain largely unexplored, particularly with regard to hepatic inflammation. We developed ultra-wideband MRE covering 5-80 Hz to investigate frequency-resolved viscoelastic dispersion of the liver and spleen and to identify biomechanical markers of hepatic inflammation. Following phantom validation, nine healthy volunteers and nine patients with inflammatory liver disease were examined at 12 frequencies. Spatiotemporal phase unwrapping and frequency-adaptive wavefield preprocessing enabled reconstruction of shear wave speed (SWS), penetration rate (PR), and loss angle ($\phi$). Six rheological models were evaluated. The largest inflammation-associated changes were observed at frequencies below 20 Hz: $\phi$ increased by 63% (p<0.001), PR decreased by 37% (p=0.003), and SWS increased by 8% (p=0.008), indicating predominantly dissipative, rather than stiffness-related, changes and a shift toward fluid-like behavior with minor stiffness changes in the lower frequency regime. The rheological springpot model with serial dashpot provided the best fit and revealed distinct dispersion functions for liver and spleen. In patients, springpot elastic modulus increased (101%, p=0.001), while viscosity and springpot power-law exponent decreased (52%, p=0.002 and 58%, p<0.001) suggesting a shift from soft-fluid to stiff-solid liver properties. Ultra-wideband MRE revealed that inflammatory liver disease is associated with property shifts toward stronger dissipation and fluid-like behavior at low frequencies while displaying solid-like behavior at higher frequencies. Ultra-low frequency MRE may provide a diagnostic window into inflammation-associated liver viscoelasticity without full rheological modeling.

physics.med-ph

ILPU: Iterative Laplace-Based Phase Unwrapping via Bi-Level Optimization

Phase unwrapping is an essential preprocessing step for phase-based MRI applications, including susceptibility mapping, field mapping, thermometry, and MR elastography. We present Iterative Laplace-Based Phase Unwrapping (ILPU), a bi-level optimization algorithm. In this method, a lower-level solver recovers a continuous phase increment from an incremental Poisson equation using the discrete cosine transform (DCT), while an upper-level solver refines an integer offset map through quality-guided spatial regularization and a restricted local search. This coupling enables robust unwrapping in low-SNR regions through adaptive smoothness penalties and quality-weighted regularization. We evaluated ILPU on 2D and 3D brain MRI phase images against manually unwrapped reference data, using standard Laplace unwrapping, Flynn, and SEGUE as comparison methods. In 2D, ILPU achieves accuracy comparable to SEGUE. In 3D, ILPU attains a relative error of 2.12% compared with 67.59% for SEGUE and 81.02% for Laplace, demonstrating a clear advantage in volumetric unwrapping. The algorithm has O(N log N) complexity per iteration through DCT-based Laplacian estimation and is numerically faster than both Flynn and SEGUE while preserving superior accuracy. These results indicate that the bi-level optimization framework provides a robust and computationally efficient solution for phase unwrapping in MRI.

math.OC

In Vivo Quantification of Glioma-Induced Solid Stress Using MR Elastography and Deformable Image Registration

Solid stress is increasingly being recognized as a key driver of tumor progression and aggressiveness, yet it has not been directly measured in patients so far. Here, we combine multifrequency magnetic resonance elastography with 3D magnetic resonance imaging (MRI)-based diffeomorphic deformable image registration network analysis to noninvasively quantify glioma-induced solid stress. In both a mouse model and patients, we identified spatially heterogeneous deformation patterns extending well beyond tumor margins. While deformation magnitude was not found to correlate with tumor size or clinical outcome, excess solid stress - defined as the product of peritumoral volumetric strain and stiffness differential between unaffected brain and peritumoral tissue - was inversely associated with patient survival, highlighting its potential as a quantitative, imaging-derived biomarker. To our knowledge, this study provides the first direct quantification of mechanical stress in patients with glioma.

physics.med-ph

In Vivo Wideband MR Elastography for Assessing Age-Related Viscoelastic Changes of the Human Brain

Magnetic Resonance Elastography (MRE) noninvasively maps brain biomechanics and is highly sensitive to alterations associated with aging and neurodegenerative disease. Most implementations use a single frequency or a narrow frequency band, limiting the analysis of frequency-dependent viscoelastic parameters. We developed a dual-actuator wideband MRE (5-50 Hz) protocol and acquired wavefields at 13 frequencies in 24 healthy adults (young: 23-39 years; older: 50-63 years). Shear wave speed (SWS) maps were generated as a proxy for stiffness, and SWS dispersion was modeled using Newtonian, Kelvin-Voigt, and power-law rheological models. Whole-brain stiffness declined with age, with the strongest effect observed at low frequencies (5-16 Hz: -0.24%/year; p=0.019) compared with mid (20-35 Hz: -0.12%/year; p=0.030) and high frequencies (40-50 Hz: -0.10%/year; p=0.165). Compared to older brains, younger adults showed 14.3% higher baseline stiffness in the power-law model (p=0.001) and 8.5-9.0% higher viscosity according to the Newtonian and Kelvin-Voigt model (p<0.05). White and cortical gray matter exhibited similar age-related decreases, while deep gray matter showed an increase in the power-law exponent (+0.001/year; p=0.036), suggesting a transition toward more fluid-like properties associated with aging. Wideband MRE revealed frequency-dependent and region-specific biomechanical alterations with aging, with the strongest effects observed at low frequencies. Extending brain MRE into the low frequency regime potentially enhances sensitivity to solid-fluid interactions. Therefore, low frequency MRE may serve as an early biomechanical marker of microstructural brain changes due to aging and neurodegeneration.

physics.med-ph

Technical recommendation on multiplex MR elastography for tomographic mapping of abdominal stiffness with a focus on the pancreas and pancreatic ductal adenocarcinoma

Objectives: MR elastography (MRE) offers valuable mechanical tissue characterization, however, in deep abdominal organs like the pancreas conventional single-driver, single-frequency approaches often fail. This study evaluates whether multiplex MRE using multiple drivers and vibration frequencies can overcome these limitations. Methods: This study used single-shot spin-echo MRE in 18 healthy volunteers targeting the liver, pancreas, kidneys, and spleen. Each healthy volunteer underwent 16 MRE examinations with different sets of four vibration frequencies (30-60 Hz) and four driver combinations, and an additional null experiment without vibrations. Further, a cohort of 14 patients with pancreatic ductal adenocarcinoma (PDAC) were retrospectively assessed. The quality of shear-wave fields and stiffness maps was assessed by displacement amplitudes and image sharpness. Results: In healthy volunteers, abdominal coverage with displacement amplitudes above the pre-determined noise level of 4 {\mu}m varied between MRE configurations: 24.2% ([0.0%-56.2%], single-driver, 60 Hz), 66.9% ([24.8%-97.7%], single-driver, 30-60 Hz), 70.2% ([0.0%-92.5%], multi-driver, 60 Hz) and 99.9% ([89.4%-100%], multi-driver, 30-60 Hz). In the pancreas, >60% coverage was achieved in all subjects using four drivers and multiple frequencies. This was achieved in only 2/18 subjects using single-driver/single-frequency MRE. Patients with PDAC had 99.1% [91.4%-100%] coverage in the pancreas and 96.3% [63.1%-100%] abdominal coverage (multi-driver, 30-60 Hz). Conclusion: MRE with four drivers and multiple vibration frequencies between 30-60 Hz enables tomographic mapping of tissue stiffness across the entire abdomen, including the pancreas. Multiplex MRE offers a promising approach for generating detailed images of abdominal stiffness, potentially enhancing clinical diagnostics for abdominal and pancreatic diseases.

physics.med-ph

Supporting Changes in Digital Ownership and Data Sovereignty Across the Automotive Value Chain with Catena-X

Digital Twins have evolved as a concept describing digital representations of physical assets. They can be used to facilitate simulations, monitoring, or optimization of product lifecycles. Considering the concept of a Circular Economy, which entails several lifecycles of, e.g., vehicles, their components, and materials, it is important to investigate how the respective Digital Twins are managed over the lifecycle of their physical assets. This publication presents and compares three approaches for managing Digital Twins in industrial use cases. The analysis considers aspects such as updates, data ownership, and data sovereignty. The results based on the research project Catena-X

cs.CY

Optical time-harmonic elastography for multiscale stiffness mapping across the phylogenetic tree

Rapid mapping of the mechanical properties of soft biological tissues from light microscopy to macroscopic imaging could transform fundamental biophysical research by providing clinical biomarkers to complement in vivo elastography. We here introduce superfast optical time-harmonic elastography (OTHE) to remotely encode surface and subsurface shear wave fields for generating maps of tissue stiffness with unprecedented detail resolution. OTHE rigorously exploits the space-time propagation characteristics of time-harmonic waves to address current limitations of biomechanical imaging and elastography. Key solutions are presented for stimulation, encoding, and stiffness reconstruction of time-harmonic, multifrequency shear waves, all tuned to provide consistent stiffness values across resolutions from microns to millimeters. OTHE's versatility is demonstrated in Bacillus subtilis biofilms, zebrafish embryos, adult zebrafish, and human skeletal muscle, reflecting the diversity of the phylogenetic tree from a mechanics perspective. By zooming in on stiffness details from coarse to finer scales, OTHE advances developmental biology and offers a way to perform biomechanics-based tissue histology that consistently matches in vivo time-harmonic elastography in patients.

physics.bio-ph