SearcharxivSearch

arXiv subjects

Tomas Stary

Publications and source records attributed to Tomas Stary.

2 recordsLinked to original sources

BeatBox - HPC Simulation Environment for Biophysically and Anatomically Realistic Cardiac Electrophysiology

The BeatBox simulation environment combines flexible script language user interface with the robust computational tools, in order to setup cardiac electrophysiology in-silico experiments without re-coding at low-level, so that cell excitation, tissue/anatomy models, stimulation protocols may be included into a BeatBox script, and simulation run either sequentially or in parallel (MPI) without re-compilation. BeatBox is a free software written in C language to be run on a Unix-based platform. It provides the whole spectrum of multi scale tissue modelling from 0-dimensional individual cell simulation, 1-dimensional fibre, 2-dimensional sheet and 3-dimensional slab of tissue, up to anatomically realistic whole heart simulations, with run time measurements including cardiac re-entry tip/filament tracing, ECG, local/global samples of any variables, etc. BeatBox solvers, cell, and tissue/anatomy models repositories are extended via robust and flexible interfaces, thus providing an open framework for new developments in the field. In this paper we give an overview of the BeatBox current state, together with a description of the main computational methods and MPI parallelisation approaches.

cs.CE

Exponential integrators for a Markov chain model of the fast sodium channel of cardiomyocytes

The modern Markov chain models of ionic channels in excitable membranes are numerically stiff. The popular numerical methods for these models require very small time steps to ensure stability. Our objective is to formulate and test two methods addressing this issue, so that the timestep can be chosen based on accuracy rather than stability. Both proposed methods extend Rush-Larsen technique, which was originally developed to Hogdkin-Huxley type gate models. One method, "Matrix Rush-Larsen" (MRL) uses a matrix reformulation of the Rush-Larsen scheme, where the matrix exponentials are calculated using precomputed tables of eigenvalues and eigenvectors. The other, "hybrid operator splitting" (HOS) method exploits asymptotic properties of a particular Markov chain model, allowing explicit analytical expressions for the substeps. We test both methods on the Clancy and Rudy (2002) INa Markov chain model. With precomputed tables for functions of the transmembrane voltage, both methods are comparable to the forward Euler method in accuracy and computational cost, but allow longer time steps without numerical instability. We conclude that both methods are of practical interest. MRL requires more computations than HOS, but is formulated in general terms which can be readily extended to other Markov Chain channel models, whereas the utility of HOS depends on the asymptotic properties of a particular model. The significance of the methods is that they allow a considerable speed-up of large-scale computations of cardiac excitation models by increasing the time step, while maintaining acceptable accuracy and preserving numerical stability.

math.NA