Searcharxiv⌕ Search

arXiv subjects

Tomonori Ikeda

Publications and source records attributed to Tomonori Ikeda.

25 records · Page 2Linked to original sources

Development of a low-$α$-emitting $μ$-PIC as a readout device for direction-sensitive dark matter detectors

Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The purpose of this study is to develop a low-background detector as a two-dimensional imaging device for a gaseous time projection chamber. In direction-sensitive dark matter experiments~(e.g. NEWAGE), $α$-rays emitted from the detector components often create substantial radioactive backgrounds. Based on the study of the background of NEWAGE, a new detector "low-$α$ $μ$-PIC" is developed. The produced $μ$-PIC performs well as a gas detector and the $α$-ray emission rate from the $μ$-PIC reduced by a factor of 100.

physics.ins-det↗

Discrimination of anisotropy in dark matter velocity distribution with directional detectors

Directional detection of dark matter has sensitivity for both recoil energy and direction of nuclear recoil. It opens the way to measure local velocity distribution of dark matter. In this paper, we study possibility to discriminate isotropic distribution and anisotropic one suggested by a N-body simulation with directional detector. Numerical simulation is performed for two cases according to the detectors, one corresponds to angular histogram and the other is energy-angular distribution of the signals. We reveal that the anisotropy of velocity distribution can be discriminated at 90% C.L. with chi-squared test if O($10^4$) signals are obtained.

hep-ph↗

Probing GHz Gravitational Waves with Graviton-magnon Resonance

A novel method for extending frequency frontier in gravitational wave observations is proposed. It is shown that gravitational waves can excite a magnon. Thus, gravitational waves can be probed by a graviton-magnon detector which measures resonance fluorescence of magnons. Searching for gravitational waves with a wave length $λ$ by using a ferromagnetic sample with a dimension $l$, the sensitivity of the graviton-magnon detector reaches spectral densities, around $5.4 \times 10^{-22} \times (\frac{l}{λ/2π})^{-2} \ [{\rm Hz}^{-1/2}]$ at 14 GHz and $8.6 \times 10^{-21} \times (\frac{l}{λ/2π})^{-2} \ [{\rm Hz}^{-1/2}]$ at 8.2 GHz, respectively.

gr-qc↗

Development of a time projection chamber with a sheet-resistor field cage

A new-concept time projection chamber (TPC) using a commercial resistive sheet, sheet-resistor micro-TPC SR-microPIC, was developed and its performance was measured. SR-microTPC has the potential to create a more uniform electric field than conventional TPCs with resistor-chains owing to its continuous sheet resistivity, and its production would be easier than that of conventional TPCs. The material used in this study, Achilles-Vynilas, was found to be thin, transparent, and low-radioactive. The performance test with cosmic muons showed very promising results, including the demonstration of a good tracking-performance. This type of TPC field cage can offer an alternative for the widely used conventional field cages

physics.ins-det↗

Prototype Analog Front-end for Negative-ion Gas and Dual-phase Liquid-Ar TPCs

We report on the recent development of a versatile analog front-end compatible with a negative-ion $μ$-TPC for a directional dark matter search as well as a dual-phase, next-generation $\mathcal{O}$(10~kt) liquid argon TPC to study neutrino oscillations, nucleon decay, and astrophysical neutrinos. Although the operating conditions for negative-ion and liquid argon TPCs are quite different (room temperature \textit{vs.} $\sim$88~K operation, respectively), the readout electronics requirements are similar. Both require a wide-dynamic range up to 1600 fC, and less than 2000--5000 e$^-$ noise for a typical signal of 80 fC with a detector capacitance of $C_{\rm det} \approx 300$~pF. In order to fulfill such challenging requirements, a prototype ASIC was newly designed using 180-nm CMOS technology. Here, we report on the performance of this ASIC, including measurements of shaping time, dynamic range, and equivalent noise charge (ENC). We also demonstrate the first operation of this ASIC on a low-pressure negative-ion $μ$-TPC.

physics.ins-det↗

Study of Negative-Ion TPC Using μ-PIC for Directional Dark Matter Search

Negative-ion time projection chambers(TPCs) have been studied for low-rate and high-resolution applications such as dark matter search experiments. Recently, a full volume fiducialization in a self-triggering TPC was realized. This innovative technology demonstrated a significant reduction in the background with MWPC-TPCs. We studied negative-ion TPC using the μ-PIC+GEM system and obtained sufficient gas gain with CS$_{2}$gas and SF$_{6}$ gas at low pressures. We expect an improvement in detector sensitivity and angular resolution with better electronics.

astro-ph.IM↗

Development of a low-alpha-emitting μ-PIC for NEWAGE direction-sensitive dark-matter search

NEWAGE is a direction-sensitive dark-matter-search experiment that uses a micro-patterned gaseous detector, or μ-PIC, as the readout. The main background sources are α-rays from radioactive contaminants in the μ-PIC. We have therefore developed a low-alpha-emitting μ-PICs and measured its performances. We measured the surface α-ray emission rate of the μ-PIC in the Kamioka mine using a surface α-ray counter based on a micro TPC.

physics.ins-det↗