Searcharxiv⌕ Search

arXiv subjects

Tomotake Matsumura

Publications and source records attributed to Tomotake Matsumura.

At least 19 recordsLinked to original sources

Development of TIFUUN: Terahertz Integral Field Units with Universal Nanotechnology

TIFUUN (THz Integral Field Units with Universal Nanotechnology) is an ultra-wideband mm-submm wave imaging spectrometer that capitalizes on the highly scalable integrated superconducting spectrometer technology. TIFUUN has two slots for integral field units (IFUs), which can jointly be optimized as open-hardware for each astronomical observation in terms of spatial and spectral coverage. These IFUs can have observation frequencies in the range of 90--360 GHz, with spectral resolution up to $R\equiv F/ΔF \le 1,000$, with up to $\sim$18,000 kinetic inductance detectors (shared by the two IFUs with a flexible ratio). The ultra-wide 4:1 (2 octave) bandwidth optics fits in a remarkably compact volume, by means of thin silicon lenses and a high chief ray angle design. The first pair of IFUs are being developed for the SUBLIME (Study of the Universe By Line Intensity Mapping Experiments) experiment that aims to map CII emission at redshift $\sim$6 to trace the cosmic large-scale structure and the buildup of galaxies during reionization, using TIFUUN on the ASTE 10-m telescope. The scalability, flexibility and compactness makes TIFUUN a highly compatible and portable system suited also for upcoming telescope facilities in the vicinity, such as FYST and AtLAST/LST.

astro-ph.IM↗

3D Printed Alumina as a Millimeter-Wave Optical Element

We present millimeter and sub-millimeter room temperature transmission and loss measurements of 3D printed alumina disc and of a disc with one-sided 3D printed sub-wavelength structures anti-reflection coatings (SWS-ARC). For four bands spanning 158 - 700~GHz we find an index of refraction consistent with $n= 3.107 \pm 0.007$. The loss over the entire frequency band between 158~GHz and 700~GHz spans $ 1 \cdot 10^{-3} \leq \tan δ\leq 2.49 \cdot 10^{-3}$ with 10%-30% uncertainty at the lower range of frequencies shrinking to $\sim\!2\%$ at the higher frequencies. As expected, constructive and destructive interference fringes that are apparent with the flat disc data are absent with the disc that has SWS-ARC. The measured data are consistent with finite element analysis predictions that are based on the measured shape of the SWS. At frequencies between 158~GHz and 200~GHz, below the onset of diffraction effects, reflectance is reduced from a maximum of 64% to about 25%, closely matching predictions. These measurements of the index, loss, and SWS-ARC of 3D printed alumina suggest that the material and fabrication technique could be useful for astrophysical applications.

astro-ph.IM↗

Silicon-based vacuum window for millimeter and submillimeter-wave astrophysics

We designed, fabricated, and characterized the properties of a silicon-based vacuum window suitable for millimeter-wave astrophysical applications. The window, which has a diameter of 124 mm, optically active diameter of 68 mm, and thickness of about 4 mm, gives an average transmittance and reflectance of 99% and 1%, respectively, a fractional bandwidth of 67%. Absorptive loss is below the detection limit of our measurement. The anti-reflection coating is made with laser ablated sub-wavelength structures (SWS), and the measured transmittance and reflectance values agree with modeling based on the measured SWS shapes. The window has been integrated into DESHIMA v2.0, an astrophysics instrument that took year-long observations with the Atacama Submillimeter Telescope Experiment.

astro-ph.IM↗

Laser ablated sub-wavelength structure anti-reflection coating on an alumina lens

We used laser ablation to fabricate sub-wavelength structure anti-reflection coating (SWS-ARC) on a 5 cm diameter alumina lens. With an aspect ratio of 2.5, the SWS-ARC are designed to give a broad-band low reflectance response between 110 and 290 GHz. SWS shape measurements conducted on both sides of the lens give 303 $μ$m pitch and total height between 750 and 790 $μ$m, matching or exceeding the aspect ratio design values. Millimeter-wave transmittance measurements in a band between 140 and 260 GHz show the increase in transmittance expected with the ARC when compared to finite element analysis electromagnetic simulations. To our knowledge, this is the first demonstration of SWS-ARC on an alumina lens, opening the path for implementing the technique for larger diameter lenses.

astro-ph.IM↗

Prototype sub-wavelength structure anti-reflection coating on alumina filters for ground-based CMB telescopes

We present designs and fabrication of sub-wavelength anti-reflection (AR) structures on alumina for infrared absorptive filters with passbands near 30, 125, and 250 GHz. These bands are widely used by ground-based instruments measuring the cosmic microwave background radiation. The designs are tuned to provide reflectance of 2% or less for fractional bandwidths between 51% and 72%, with each of the three primary bands containing two sub-bands. We make the sub-wavelength structures (SWS), which resemble a two-dimensional array of pyramids, using laser ablation. We measure the shapes of the fabricated pyramids and show that for incidence angles up to 20 degrees the predicted in-band average reflectance is 2% or less, in agreement with the design. The band average instrumental polarization is less than $3\times 10^{-3}$.

astro-ph.IM↗

A measurement of atmospheric circular polarization with POLARBEAR

At millimeter wavelengths, the atmospheric emission is circularly polarized owing to the Zeeman splitting of molecular oxygen by the Earth's magnetic field. We report a measurement of the signal in the 150 GHz band using 3 years of observational data with the \textsc{Polarbear} project. Non-idealities of a continuously rotating half-wave plate (HWP) partially convert circularly polarized light to linearly polarized light. While \textsc{Polarbear} detectors are sensitive to linear polarization, this effect makes them sensitive to circular polarization. Although this was not the intended use, we utilized this conversion to measure circular polarization. We reconstruct the azimuthal gradient of the circular polarization signal and measure its dependency from the scanning direction and the detector bandpass. We compare the signal with a simulation based on atmospheric emission theory, the detector bandpass, and the HWP leakage spectrum model. We find the ratio of the observed azimuthal slope to the simulated slope is $0.92 \pm 0.01\rm{(stat)} \pm 0.07\rm{(sys)}$. This ratio corresponds to a brightness temperature of $3.8\,\mathrm{m K}$ at the effective band center of $121.8\,\mathrm{GHz}$ and bandwidth of $3.5\,\mathrm{GHz}$ estimated from representative detector bandpass and the spectrum of Zeeman emission. This result validates our understanding of the instrument and reinforces the feasibility of measuring the circular polarization using the imperfection of continuously rotating HWP. Continuously rotating HWP is popular in ongoing and future cosmic microwave background experiments to modulate the polarized signal. This work shows a method for signal extraction and leakage subtraction that can help measuring circular polarization in such experiments.

astro-ph.IM↗

Impact of half-wave plate systematics on the measurement of CMB $B$-mode polarization

Polarization of the cosmic microwave background (CMB) can help probe the fundamental physics behind cosmic inflation via the measurement of primordial $B$ modes. As this requires exquisite control over instrumental systematics, some next-generation CMB experiments plan to use a rotating half-wave plate (HWP) as polarization modulator. However, the HWP non-idealities, if not properly treated in the analysis, can result in additional systematics. In this paper, we present a simple, semi-analytical end-to-end model to propagate the HWP non-idealities through the macro-steps that make up any CMB experiment (observation of multi-frequency maps, foreground cleaning, and power spectra estimation) and compute the HWP-induced bias on the estimated tensor-to-scalar ratio, $r$. We find that the effective polarization efficiency of the HWP suppresses the polarization signal, leading to an underestimation of $r$. Laboratory measurements of the properties of the HWP can be used to calibrate this effect, but we show how gain calibration of the CMB temperature can also be used to partially mitigate it. On the basis of our findings, we present a set of recommendations for the HWP design that can help maximize the benefits of gain calibration.

astro-ph.CO↗

The Simons Observatory: Development and Optical Evaluation of Achromatic Half-Wave Plates

The Simons Observatory (SO) experiment is a cosmic microwave background (CMB) experiment located in the Atacama Desert, Chile. The SO' s small aperture telescopes (SATs) consist of three telescopes designed for precise CMB polarimetry at large angular scales. Each SAT uses a cryogenic rotating half-wave plate (HWP) as a polarization modulator to mitigate atmospheric 1/f noise and other systematics. To realize efficient polarization modulation over the observation bands, we fabricated an achromatic HWP (AHWP) consisting of three sapphire plates with anti-reflection coatings. The AHWP is designed to have broadband modulation efficiency and transmittance. This paper reports on the design and the preliminary characterization of the AHWPs for SATs.

astro-ph.IM↗

Anti-reflection coating with mullite and Duroid for large-diameter cryogenic sapphire and alumina optics

We developed a broadband two-layer anti-reflection (AR) coating for use on a sapphire half-wave plate (HWP) and an alumina infrared (IR) filter for the cosmic microwave background (CMB) polarimetry. Measuring the faint CMB B-mode signals requires maximizing the number of photons reaching the detectors and minimizing spurious polarization due to reflection with an off-axis incident angle. Sapphire and alumina have high refractive indices of 3.1 and are highly reflective without an AR coating. This paper presents the design, fabrication, quality control, and measured performance of an AR coating using thermally-sprayed mullite and Duroid 5880LZ. This technology enables large optical elements with diameters of 600 mm. We also present a newly developed thermography-based nondestructive quality control technique, which is key to assuring good adhesion and preventing delamination when thermal cycling. We demonstrate the average reflectance of about 2.6% (0.9%) for two observing bands centered at 90/150 (220/280) GHz. At room temperature, the average transmittance of a 105 mm square test sample at 220/280 GHz is 83%, and it will increase to 90% at 100 K, attributed to reduced absorption losses. Therefore, our developed layering technique has proved effective for 220/280 GHz applications, particularly in addressing dielectric loss concerns. This AR coating technology has been deployed in the cryogenic HWP and IR filters of the Simons Array and the Simons observatory experiments and applies to future experiments such as CMB-S4.

astro-ph.IM↗

Effect of Instrumental Polarization with a Half-Wave Plate on the $B$-Mode Signal: Prediction and Correction

We evaluate the effect of half-wave plate (HWP) imperfections inducing intensity leakage to the measurement of Cosmic Microwave Background (CMB) $B$-mode polarization signal with future satellite missions focusing on the tensor-to-scalar ratio $r$. The HWP is modeled with the Mueller formalism, and coefficients are decomposed for any incident angle into harmonics of the HWP rotation frequency due to azimuthal angle dependence. Although we use a general formalism, band-averaged matrix coefficients are calculated as an example for a 9-layer sapphire HWP using EM propagation simulations. We perform simulations of multi-detector observations in a band centered at 140\,GHz using \LB instrumental configuration. We show both theoretically and with the simulations that most of the artefacts on Stokes parameter maps are produced by the dipole leakage on $B$-modes induced by the fourth harmonics $M^{(4f)}_{QI}$ and $M^{(4f)}_{UI}$. The resulting effect is strongly linked to the spin-2 focal plane scanning cross linking parameters. We develop a maximum likelihood-based method to correct the IP leakage by joint fitting of the Mueller matrix coefficients as well as the Stokes parameter maps. % by modifying the standard map-making procedure. We show that the residual leakage after correction leads to an additional noise limited uncertainty on $r$ of the order of $10^{-7}$, independently of the value of the Mueller matrix coefficients. We discuss the impact of the monopole signal and the potential coupling with other systematic effects such as gain variations and detector nonlinearities.

astro-ph.CO↗

Vibration characteristics of a continuously rotating superconducting magnetic bearing and potential influence to TES and SQUID

We measured the vibration of a prototype superconducting magnetic bearing (SMB) operating at liquid nitrogen temperature. This prototype system was designed as a breadboard model for LiteBIRD low-frequency telescope (LFT) polarization modulator unit. We set an upper limit of the vibration amplitude at $36~\mathrm{μm}$ at the rotational synchronous frequency. During the rotation, the amplitude of the magnetic field produced varies. From this setup, we compute the static and AC amplitude of the magnetic fields produced by the SMB magnet at the location of the LFT focal plane as $0.24~\mathrm{G}$ and $3\times10^{-5}$$~\mathrm{G}$, respectively. From the AC amplitude, we compute TES critical temperature variation of $7\times10^{-8}$$~\mathrm{K}$ and fractional change of the SQUID flux is $δΦ/Φ_0|_{ac}=3.1\times10^{-5}$. The mechanical vibration can be also estimated to be $3.6\times 10^{-2}$$~\mathrm{N}$ at the rotation mechanism location.

physics.ins-det↗

Testbed preparation of a small prototype polarization modulator for LiteBIRD low-frequency telescope

LiteBIRD is the Cosmic Microwave Background (CMB) radiation polarization satellite mission led by ISAS/JAXA. The main scientific goal is to search for primordial gravitational wave signals generated from the inflation epoch of the Universe. LiteBIRD telescopes employ polarization modulation units (PMU) using continuously rotating half-wave plates (HWP). The PMU is a crucial component to reach unprecedented sensitivity by mitigating systematic effects, including 1/f noise. We have developed a 1/10 scale prototype PMU of the LiteBIRD LFT, which has a 5-layer achromatic HWP and a diameter of 50 mm, spanning the observational frequency range of 34-161 GHz. The HWP is mounted on a superconducting magnetic bearing (SMB) as a rotor and levitated by a high-temperature superconductor as a stator. In this study, the entire PMU system is cooled down to 10 K in the cryostat chamber by a 4-K Gifford-McMahon (GM) cooler. We propagate an incident coherent millimeter-wave polarized signal throughout the rotating HWP and detect the modulated signal. We study the modulated optical signal and any rotational synchronous signals from the rotation mechanism. We describe the testbed system and the preliminary data acquired from this setup. This testbed is built to integrate the broadband HWP PMU and evaluate the potential systematic effects in the optical data. This way, we can plan with a full-scale model, which takes a long time for preparation and testing.

astro-ph.IM↗

Modelling TES non-linearity induced by a rotating HWP in a CMB polarimeter

Most upcoming CMB experiments are planning to deploy between a few thousand and a few hundred thousand TES bolometers in order to drastically increase sensitivity and unveil the B-mode signal. Differential systematic effects and $1/f$ noise are two of the challenges that need to be overcome in order to achieve this result. In recent years, rotating Half-Wave Plates have become increasingly more popular as a solution to mitigate these effects, especially for those experiments that are targeting the largest angular scales. However, other effects may appear when a rotating HWP is being employed. In this paper we focus on HWP synchronous signals, which are due to intensity to polarization leakage induced by a rotating cryogenic multi-layer sapphire HWP employed as the first optical element of the telescope system. We use LiteBIRD LFT as a case study and we analyze the interaction between these spurious signals and TES bolometers, to determine whether this signal can contaminate the bolometer response. We present the results of simulations for a few different TES model assumptions and different spurious signal amplitudes. Modelling these effects is fundamental to find what leakage level can be tolerated and minimize non-linearity effects of the bolometer response.

astro-ph.IM↗

Testing magnetic interference between TES detectors and the telescope environment for future CMB satellite missions

The two most common components of several upcoming CMB experiments are large arrays of superconductive TES (Transition-Edge Sensor) detectors and polarization modulator units, e.g. continuously-rotating Half-Wave Plates (HWP). A high detector count is necessary to increase the instrument raw sensitivity, however past experiments have shown that systematic effects are becoming one of the main limiting factors to reach the sensitivity required to detect primordial $B$-modes. Therefore, polarization modulators have become popular in recent years to mitigate several systematic effects. Polarization modulators based on HWP technologies require a rotating mechanism to spin the plate and modulate the incoming polarized signal. In order to minimize heat dissipation from the rotating mechanism, which is a stringent requirement particularly for a space mission like $LiteBIRD$, we can employ a superconductive magnetic bearing to levitate the rotor and achieve contactless rotation. A disadvantage of this technique is the associated magnetic fields generated by those systems. In this paper we investigate the effects on a TES detector prototype and find no detectable $T_c$ variations due to an applied constant (DC) magnetic field, and a non-zero TES response to varying (AC) magnetic fields. We quantify a worst-case TES responsivity to the applied AC magnetic field of $\sim10^5$ pA/G, and give a preliminary interpretation of the pick-up mechanism.

astro-ph.IM↗

A Large Diameter Millimeter-Wave Low-Pass Filter Made of Alumina with Laser Ablated Anti-Reflection Coating

We fabricated a 302 mm diameter low-pass filter made of alumina that has an anti-reflection coating (ARC) made with laser-ablated sub-wavelength structures (SWS). The filter has been integrated into and is operating with the MUSTANG2 instrument, which is coupled to the Green Bank Telescope. The average transmittance of the filter in the MUSTANG2 operating band between 75 and 105 GHz is 98%. Reflective loss due to the ARC is 1%. The difference in transmission between the s- and p-polarization states is less than 1%. To within 1% accuracy we observe no variance in these results when transmission is measured in six independent filter spatial locations. The alumina filter replaced a prior MUSTANG2 Teflon filter. Data taken with the filter heat sunk to its nominal 40 K stage show performance consistent with expectations: a reduction of about 50% in filters-induced optical power load on the 300 mK stage, and in in-band optical loading on the detectors. It has taken less than 4 days to laser-ablate the SWS on both sides of the alumina disk. This is the first report of an alumina filter with SWS ARC deployed with an operating instrument, and the first demonstration of a large area fabrication of SWS with laser ablation.

astro-ph.IM↗

In-flight polarization angle calibration for LiteBIRD: blind challenge and cosmological implications

We present a demonstration of the in-flight polarization angle calibration for the JAXA/ISAS second strategic large class mission, LiteBIRD, and estimate its impact on the measurement of the tensor-to-scalar ratio parameter, r, using simulated data. We generate a set of simulated sky maps with CMB and polarized foreground emission, and inject instrumental noise and polarization angle offsets to the 22 (partially overlapping) LiteBIRD frequency channels. Our in-flight angle calibration relies on nulling the EB cross correlation of the polarized signal in each channel. This calibration step has been carried out by two independent groups with a blind analysis, allowing an accuracy of the order of a few arc-minutes to be reached on the estimate of the angle offsets. Both the corrected and uncorrected multi-frequency maps are propagated through the foreground cleaning step, with the goal of computing clean CMB maps. We employ two component separation algorithms, the Bayesian-Separation of Components and Residuals Estimate Tool (B-SeCRET), and the Needlet Internal Linear Combination (NILC). We find that the recovered CMB maps obtained with algorithms that do not make any assumptions about the foreground properties, such as NILC, are only mildly affected by the angle miscalibration. However, polarization angle offsets strongly bias results obtained with the parametric fitting method. Once the miscalibration angles are corrected by EB nulling prior to the component separation, both component separation algorithms result in an unbiased estimation of the r parameter. While this work is motivated by the conceptual design study for LiteBIRD, its framework can be broadly applied to any CMB polarization experiment. In particular, the combination of simulation plus blind analysis provides a robust forecast by taking into account not only detector sensitivity but also systematic effects.

astro-ph.CO↗

Mechanical strength and millimeter-wave transmittance spectrum of stacked sapphire plates bonded by sodium silicate solution

The polarization modulator unit for the low-frequency telescope in LiteBIRD employs an achromatic half-wave plate (AHWP). It consists of five layers of a-cut sapphire plate, which are stacked based on a Pancharatnam recipe. In this way, the retardance of the AHWP is a half-wave over a bandwidth of 34-161 GHz. The diameter of a single sapphire plate is about 500 mm and the thickness is 5 mm. When a large diameter AHWP is used for a space mission, it is important for the AHWP to survive launch vibration. A preliminary study indicates that the five-layer stacked HWP has a risk of breakage at the launch unless the five layers are glued together and mechanically treated as one disk. We report our investigation using a sodium silicate solution that can bond the sapphire plates. This technique has been previously investigated as a candidate of cryogenic bonding for a mirror material, including sapphire, of the gravitational wave experiments: LIGO, VIRGO, and KAGRA. We experimentally studied the mechanical strength of the bonded interface for two different surface conditions: polished and unpolished. We demonstrated that the tensile and shear strength > 20 MPa for samples with a polished surface. This satisfied the requirement of 5.5 MPa derived from the mechanical simulation assuming a launch load of 30G. We identified that samples glued on a polished surface exhibit higher strength than unpolished ones by a factor of 2 for tensile and 18 for shear strength. We measured the millimeter-wave transmittance between 90 and 140 GHz using sapphire plates with a diameter of 50 mm before and after bonding. We did not find any optical effects caused by the bonded interface within 2% error in transmittance, which originates from the measurement system.

astro-ph.IM↗

Design of a frequency-independent optic axis Pancharatnam-based achromatic half-wave plate

Pancharatnam-based achromatic half-wave plates (AHWP) achieve high polarization efficiency over a broad waveband. These AWHPs generally contain a property whereby the optic axis is dependent on the electromagnetic frequency of the incident radiation. When the AHWP is used to measure incident polarized radiation with a finite detection bandwidth, this frequency dependence causes an uncertainty in the determination of the polarization angle due to the limited knowledge of the shape of the source spectrum and detection band. To mitigate this problem, we propose new designs of the AHWP which eliminate the frequency dependence of the optic axis over the bandwidth whilst maintaining high modulation efficiency. We carried out this optimization by tuning the relative angles among the individual half-wave plates of the five and nine layer AHWPs. The optimized set of relative angles achieves a frequency-independent optic axis over the fractional bandwidth, a bandwidth over which polarization efficiency is greater than 0.9, of 1.3 and 1.5 for the five and nine layer AHWPs, respectively. We also study the susceptibility of the alignment accuracy on the polarization efficiency and the frequency dependence of the optic axis, which provides a design guidance for each application.

astro-ph.IM↗