SearcharxivSearch

arXiv subjects

Tony Denault

Publications and source records attributed to Tony Denault.

2 recordsLinked to original sources

Facility integration of the NASA IRTF adaptive secondary mirror

IRTF-ASM-1 has been functioning well since its first light in 2024. This adaptive secondary mirror (ASM) was primarily developed to be an on-sky demonstration of the new hybrid variable reluctance actuator technology at the NASA Infrared Telescope Facility (IRTF). However, due to its physical robustness and our previous demonstrations of sensitivity enhancements with the ASM, we are interested in using it to optimize telescope image quality on a nightly basis. This will directly benefit science observations. However, as IRTF does not currently have adaptive optics expertise, we have been developing the system to be used with minimal human intervention. We present our progress in developing software for active optics mode with IRTF-ASM-1 using the single conjugate, facility 2x2 Shack-Hartmann wavefront sensor Felix. We also present techniques for removing low-order, large amplitude non-common path aberrations between Felix and our science instruments.

astro-ph.IM

Progress report on the integration of the IRTF adaptive secondary mirror

IRTF-ASM-1 is the first on-sky adaptive secondary mirror using the hybrid variable reluctance (HVR) actuators developed by the Netherlands Organization for Applied Scientific Research (TNO). Since its first light in April 2024, the ASM has continued to work consistently well with no hardware issues. The primary purpose of IRTF-ASM-1 is to serve as a demonstration of the HVR actuator technology, both in terms of verifying its robustness and testing calibration methods that are relevant to larger ASMs. However, as the ASM has proven to be easy to handle and reliable in its performance, we are moving toward integrating the ASM for long-term use at IRTF. We present closed loop results with the ASM and IRTF's off-axis facility wavefront sensor FELIX. Correcting the first seven Zernike modes through coma at 90-180 Hz, we are able to enhance the seeing by a factor of 1.8 in FWHM under 0."5 seeing conditions. We also performed the first science observations with the ASM in "static" mode and demonstrated that we can improve the throughput of IRTF's slit spectrograph by approximately a factor of 2, although this requires good reference slopes in FELIX. In the near future, we plan to optimize the calibration of reference slopes in FELIX and streamline the software so that the system can be operated by a non-AO expert.

astro-ph.IM