SearcharxivSearch

arXiv subjects

Tony Salloom

Publications and source records attributed to Tony Salloom.

3 recordsLinked to original sources

Geometry-Aware Sparse Depth Sampling for High-Fidelity RGB-D Depth Completion in Robotic Systems

Accurate three-dimensional perception is essential for modern industrial robotic systems that perform manipulation, inspection, and navigation tasks. RGB-D and stereo vision sensors are widely used for this purpose, but the depth maps they produce are often noisy, incomplete, or biased due to sensor limitations and environmental conditions. Depth completion methods aim to generate dense, reliable depth maps from RGB images and sparse depth input. However, a key limitation in current depth completion pipelines is the unrealistic generation of sparse depth: sparse pixels are typically selected uniformly at random from dense ground-truth depth, ignoring the fact that real sensors exhibit geometry-dependent and spatially nonuniform reliability. In this work, we propose a normal-guided sparse depth sampling strategy that leverages PCA-based surface normal estimation on the RGB-D point cloud to compute a per-pixel depth reliability measure. The sparse depth samples are then drawn according to this reliability distribution. We integrate this sampling method with the Marigold-DC diffusion-based depth completion model and evaluate it on NYU Depth v2 using the standard metrics. Experiments show that our geometry-aware sparse depth improves accuracy, reduces artifacts near edges and discontinuities, and produces more realistic training conditions that better reflect real sensor behavior.

cs.CV

A Novel Deep Neural Network Architecture for Real-Time Water Demand Forecasting

Short-term water demand forecasting (StWDF) is the foundation stone in the derivation of an optimal plan for controlling water supply systems. Deep learning (DL) approaches provide the most accurate solutions for this purpose. However, they suffer from complexity problem due to the massive number of parameters, in addition to the high forecasting error at the extreme points. In this work, an effective method to alleviate the error at these points is proposed. It is based on extending the data by inserting virtual data within the actual data to relieve the nonlinearity around them. To our knowledge, this is the first work that considers the problem related to the extreme points. Moreover, the water demand forecasting model proposed in this work is a novel DL model with relatively low complexity. The basic model uses the gated recurrent unit (GRU) to handle the sequential relationship in the historical demand data, while an unsupervised classification method, K-means, is introduced for the creation of new features to enhance the prediction accuracy with less number of parameters. Real data obtained from two different water plants in China are used to train and verify the model proposed. The prediction results and the comparison with the state-of-the-art illustrate that the method proposed reduces the complexity of the model six times of what achieved in the literature while conserving the same accuracy. Furthermore, it is found that extending the data set significantly reduces the error by about 30%. However, it increases the training time.

cs.LG

Proportional integral derivative booster for neural networks-based time-series prediction: Case of water demand prediction

Multi-step time-series prediction is an essential supportive step for decision-makers in several industrial areas. Artificial intelligence techniques, which use a neural network component in various forms, have recently frequently been used to accomplish this step. However, the complexity of the neural network structure still stands up as a critical problem against prediction accuracy. In this paper, a method inspired by the proportional-integral-derivative (PID) control approach is investigated to enhance the performance of neural network models used for multi-step ahead prediction of periodic time-series information while maintaining a negligible impact on the complexity of the system. The PID-based method is applied to the predicted value at each time step to bring that value closer to the real value. The water demand forecasting problem is considered as a case study, where two deep neural network models from the literature are used to prove the effectiveness of the proposed boosting method. Furthermore, to prove the applicability of this PID-based booster to other types of periodic time-series prediction problems, it is applied to enhance the accuracy of a neural network model used for multi-step forecasting of hourly energy consumption. The comparison between the results of the original prediction models and the results after using the proposed technique demonstrates the superiority of the proposed method in terms of prediction accuracy and system complexity.

cs.LG