SearcharxivSearch

arXiv subjects

Tonya L. Peshel

Publications and source records attributed to Tonya L. Peshel.

7 recordsLinked to original sources

Fast, low noise, megapixel detector and readout systems for future X-ray astronomy missions

Next-generation strategic X-ray astronomy missions will require the simultaneous achievement of high angular resolution, large effective collecting area, and wide-field imaging with large-format focal plane detectors. Realizing the associated science objectives--ranging from precision measurements of bright point sources to the detection and characterization of faint diffuse emission-places stringent and, in some cases, competing requirements on detector performance. In particular, high frame rates are necessary to mitigate photon pile-up in observations of bright sources and to reduce contamination from particle-induced background in measurements of low surface brightness structures. At the same time, these instruments must preserve excellent soft X-ray response, which places tight constraints on read noise and on the fidelity of event characterization. State-of-the-art X-ray charge-coupled devices (CCDs) approach many of the key performance metrics required for these missions, but readout speed remains a primary limitation. Addressing this gap requires readout architectures that scale to high channel count, sustain high pixel throughput, and preserve the low-noise characteristics needed for soft X-ray sensitivity.

astro-ph.IM

High-speed, low-noise, multi-megapixel CCDs for next generation X-ray observatories

Next generation X-ray observatories require fast, low-noise, low-power, multi-megapixel imaging spectrometers. To meet these demands, the X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in partnership with the MIT Kavli Institute and MIT Lincoln Laboratory (MIT-LL), is developing multi-channel X-ray charge-coupled devices (CCDs) and fast readout architectures. We report the energy resolution and noise performance achieved with a full-scale (1440x1440-pixel), 16-channel, front-illuminated MIT-LL CCD detector developed for the Advanced X-ray Imaging Satellite (AXIS) concept, the CCID-100, read out using two Multi-Channel Readout Chip (MCRC) V1 application-specific integrated circuit (ASIC) chips in the new Stanford CCID-100 test setup. We describe an automated method for bias optimization on each CCD channel, and integrated debugging features of the front-end ASIC and readout system. The demonstrated performance confirms that these systems can meet the speed and noise requirements of future strategic X-ray missions.

astro-ph.IM

Output-Stage Design Optimization for High-Sensitivity SiSeRO CCDs and SiSeRO Active Pixel Sensors

The Single electron Sensitive Read Out (SiSeRO) technology is a new device class designed to support the needs of future X-ray and optical astronomical telescopes that will require fast, low-noise, megapixel spectro-imagers. Developed at MIT Lincoln Laboratory, in collaboration with Stanford University and MIT, the first generation SiSeRO-CCD (charge-coupled device) prototypes achieved a charge/current conversion gain of 700$-$800 pA per electron, an equivalent noise charge (ENC) of around 3.5 electrons root mean square (RMS), and a full width half maximum (FWHM) energy resolution of approximately 130 eV at 5.9 keV at a readout speed of 625 kpix/s. Utilizing Repetitive Non-Destructive Readout (RNDR), these same devices also demonstrated sub-electron noise performance (ENC$<$0.5 electrons RMS) at a readout speed of 10 kpix/s. We present the results of device simulations for next-generation SiSeRO CCD output stages that optimize the sensing transistor and its internal gate geometry to enhance noise and speed performance. Further, the goal is to develop a SiSeRO active pixel sensor (APS) that combines the proven X-ray performance of CCDs with the architectural advantages of an APS. Enabling this requires substantial design updates, for example, incorporating two SiSeRO amplifiers side by side on each pixel and shuffling the charge between them to support RNDR. We discuss our device simulation framework and design parameter optimization in the first-generation SiSeRO devices.

astro-ph.IM

Fast, low-noise CCD systems for future strategic X-ray missions

Future strategic X-ray missions, such as those targeted by the Great Observatories Maturation Program (GOMaP), require fast, low-noise X-ray imaging spectrometers. To achieve the speed and noise capabilities required by such programs, our Stanford team, in collaboration with the MIT Kavli Institute (MKI) and MIT Lincoln Laboratory (MIT-LL), is developing enhanced X-ray charge-coupled devices (CCDs) and readout systems that leverage tailored application-specific integrated circuits (ASICs). Here, we report the energy resolution and noise performance achieved using some of the latest MIT-LL CCDs in conjunction with Stanford-developed Multi-Channel Readout Chip (MCRC) ASICs. Additionally, we present a new sampling method for simultaneous optimization of the output gate (OG), reset gate (RG), and reset drain (RD) biases which, in combination with new integrated fast summing well (SW) and RG clock operation modes, enables the data rates and noise required for future X-ray telescopes. Finally, we present noise power spectral density (PSD) and waveform analysis methods and posit a physical model for characterizing and understanding output stage noise behavior.

astro-ph.IM

The High-Speed FPGA Readout System for the Advanced X-ray Imaging Satellite (AXIS)

The Advanced X-ray Imaging Satellite (AXIS) is a Probe-class mission concept designed to deliver arcsecond spatial resolution, high-sensitivity spectral imaging across the 0.3-10 keV band. The X-ray Astronomy and Observational Cosmology (XOC) Group at Stanford, in collaboration with the MIT Kavli Institute (MKI) and MIT Lincoln Laboratory (MIT-LL), is developing the AXIS X-ray camera, including both the detector and the front-end readout electronics required to meet the mission's demanding performance goals. The telescope's focal plane detector consists of four 1440x1440 pixel charge-coupled devices (CCDs) developed by MIT-LL, each featuring 16 parallel output channels. These outputs are amplified by a high-speed, low-power, low-noise application-specific integrated circuit (ASIC) - the Multi-Channel Readout Chip (MCRC) - developed at Stanford. Following amplification, the analog signals are digitized and processed to construct a pixel array, prior to event detection. Here, we present the field-programmable gate array (FPGA) architecture developed to enable high-speed, parallelized readout of these CCD channels. The FPGA samples 16 analog-to-digital converter (ADC) channels at 50 MHz, performs preprocessing of pixel data, which is then streamed via User Datagram Protocol (UDP) over a 1 Gb Ethernet link to the back-end system for event reconstruction. Our design demonstrates the goal readout performance for AXIS (20 frames per second) and provides a framework for future high-throughput X-ray observatories.

astro-ph.IM

RNDR noise modeling in first-generation Single electron Sensitive Readout (SiSeRO) devices

Flagship observatories require single-photon detectors with ultra-fast readout, sub-electron noise performance, and scalable large-format architectures. The X-ray Astronomy and Observational Cosmology group at Stanford, in collaboration with the MIT Kavli Institute and MIT Lincoln Laboratory, is developing readout technologies for next-generation detectors. Prototypes employing Single-electron Sensitive Readout (SiSeRO) amplifiers demonstrate excellent read noise and spectral performance using repetitive non-destructive readout (RNDR), achieving 0.5 e$^-$ noise in under 57 cycles. We have modeled noise for longer RNDR cycles, exploring probabilistic mechanisms such as thermal leakage and impact ionization. Here we present our model results, including statistical limits on dark current-like signals. Maturation of SiSeRO technology will improve detector performance at soft X-ray energies, addressing technology gaps for future X-ray and UV/visible/near-IR observatories.

astro-ph.IM

First results for second generation SiSeRO CCD devices

The Astro2020 Decadal recommended the development of a suite of next generation astronomical observatories spanning the X-ray to near-IR spectrum. These programs require fast, extremely low noise detectors to fulfill their science goals. To address this technology gap, Stanford X-ray Astronomy and Observational Cosmology (XOC) group, MIT Lincoln Laboratory (MIT-LL), and MIT Kavli Institute (MKI) are advancing Single electron Sensitive Read Out (SiSeRO), a multiband detector technology capable of achieving substantially sub-electron noise via Repetitive Non-Destructive Readout (RNDR). We present initial results for our second generation SiSeRO CCDs. We also discuss our test bed, including a readout electronics system capable of accommodating all second-generation SiSeRO CCD variants utilizing the XOC-designed Multi-Channel Readout Chip (MCRC) ASIC.

astro-ph.IM