Searcharxiv⌕ Search

arXiv subjects

Toshiyuki Iwamoto

Publications and source records attributed to Toshiyuki Iwamoto.

4 recordsLinked to original sources

Performance of an LYSO-Based Active Converter for a Conversion Spectrometer aiming for 52.8 MeV photon detection in Future $μ^+ \to e^+ γ$ Search Experiments

To facilitate future $μ^+ \to e^+ γ$ search experiments with a branching-ratio sensitivity of $10^{-15}$, we are developing a conversion spectrometer that incorporates an active LYSO converter. The converter generates $e^+e^-$ pairs from incident photons while simultaneously measuring their energy deposition and timing, thereby enabling precise reconstruction of 52.8 MeV photons. The design goals include a time resolution of 30 ps and an energy resolution of 200 keV for the detection of 52.8 MeV photons. Based on simulation studies, we optimized the converter thickness and segment dimensions, followed by the fabrication of prototype LYSO segments. The single-MIP detection performance of these prototypes was evaluated using an electron beam at the KEK PF-AR test beamline. The prototypes demonstrated excellent performance, achieving a time resolution of 25 ps and a light yield of $10^4$ photoelectrons, both of which significantly exceed the design requirements.

physics.ins-det↗

Letter Of Intent for a future $μ^+ \to \mathrm{e}^+ γ$ experiment at the High Intensity Muon Beam facility at PSI

Searches for charged lepton flavor violation in the muon sector stand out among the most sensitive and clean probes for physics beyond the Standard Model. Currently, $μ^+ \to \mathrm{e}^+ γ$ experiments provide the best constraints in this field for a wide range of models while, in the coming years, new experiments investigating the processes of $μ^+ \to \mathrm{e}^+ \mathrm{e}^+ \mathrm{e}^-$ and $μ\to \mathrm{e}$ conversion in the nuclear field are anticipated to reach comparable or higher sensitivities. The High-Intensity Muon Beam (HIMB) facility at PSI, which is expected to deliver muon beam intensities up to two orders of magnitude higher than the existing beam lines, offers a unique opportunity to significantly enhance the sensitivity of $μ^+ \to \mathrm{e}^+ γ$ searches. The discovery potential could be substantially boosted and a sensitivity comparable to that of all the other projects could be reestablished, which is essential for discriminating among competing new-physics scenarios should an observation occur in any of the channels. In this document, we express our interest in developing a $μ^+ \to \mathrm{e}^+ γ$ experimental program at HIMB, with the goal of improving, within the next decade, the sensitivity of the $μ^+ \to \mathrm{e}^+ γ$ search by more than one order of magnitude relative to the expected final result of the current leading experiment, MEG II. This effort would ensure that PSI retains its leadership in this field.

hep-ex↗

Photon energy reconstruction with the MEG II liquid xenon calorimeter

The MEG II experiment searches for a charged-lepton-flavour-violating $μ\to e γ$ with the target sensitivity of $6 \times 10^{-14}$. A liquid xenon calorimeter with VUV-sensitive photosensors measures photon position, timing, and energy. This paper concentrates on the precise photon energy reconstruction with the MEG II liquid xenon calorimeter. Since a muon beam rate is $3\text{-}5 \times 10^{7}~\text{s}^{-1}$, multi-photon elimination analysis is performed using waveform analysis techniques such as a template waveform fit. As a result, background events in the energy range of 48-58 MeV were reduced by 34 %. The calibration of the energy scale of the calorimeter with several calibration sources is also discussed to achieve a high resolution of 1.8 %.

physics.ins-det↗

The Search for $μ^+\to e^+ γ$ with 10$^{-14}$ Sensitivity: the Upgrade of the MEG Experiment

The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$) $<4.2 \times 10^{-13}$ at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of $6\times10^{-14}$. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ($7\times10^{7}$ muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.

hep-ex↗