SearcharxivSearch

arXiv subjects

Tsunayuki Matsubara

Publications and source records attributed to Tsunayuki Matsubara.

3 recordsLinked to original sources

Semiautomatic dimensional screening of plastic scintillator cubes using image analysis and robotics

Large-scale particle physics detectors often contain millions of repeated components, making precise and efficient quality control essential. We have developed a semiautomatic system for dimensional screening of 1 cm$^3$ plastic scintillator cubes for their potential use in future neutrino detectors. The system employs a motorized rotating stage, six high-resolution cameras, and image analysis software to measure cube size, surface protrusions, and the positions of holes for wavelength-shifting fibers used in optical readout. Based on these measurements, each cube is automatically classified as either acceptable or defective. We constructed and validated a prototype system, achieving a measurement precision of 10 $μ$m and over 80% consistency with manual screening. To enable classification of cubes into 48 groups based on hole positions while preserving their orientation, we introduced a 6-axis robotic arm. The completed system achieved a rejection rate of 3.1%. Our approach contributes to scalable, precise, and efficient quality control for future large-scale particle physics detectors.

physics.ins-det

Performance evaluation of electron multiplier tubes as a high-intensity muon beam monitor of accelerator neutrino experiments

Upgrade work towards increasing the beam intensity of the neutrino beamline at J- PARC is underway. Monitoring tertiary muon beams is essential for stable operation of the beamline. Accordingly, we plan to replace the present muon monitor sensors with electron multiplier tubes (EMTs). We investigated the radiation tolerance and linearity response of EMTs using a 90 MeV electron beam. An EMTs was irradiated with electrons up to 470 nC. EMTs show higher radiation tolerance than the Si sensors which are presently used as one of the muon monitor detectors for the T2K long-baseline neutrino experiment at J-PARC. The integrated charge yield decrease is found to be less than 8% after a beam irradiation equivalent to 132 days of operation at the future J-PARC beam power of 1.3 MW. The EMTs show linearity better than $\pm$5% up to the future beam intensity. The observed yield decrease is likely due to dynode deterioration based on the detailed investigation. The studies described here confirm that EMTs can be used as a high-intensity muon beam monitor. From the reported results, we are proceeding with the installation in the J-PARC neutrino beamline.

physics.ins-det

First result from the Double Chooz reactor-neutrino experiment

We report first results of a search for the non-zero neutrino mixing angle θ_{13} from the Double Chooz experiment. Double Chooz aims to measure the mixing angle based on anti-electron-neutrino disappearance as a consequence of neutrino oscillation. A new generation of anti-electron-neutrino detector having 10 m^3 fiducial volume is located 1 km from the two 4.25 GW_{th} reactors at the Chooz Power Plant in France. Physics data taking has been continuing since April 2011. A ratio of observed-to-predicted event rate of 0.944 +/- 0.016 (stat) +/- 0.040 (syst) was obtained in 101 days of detector running. Analyzing both the rate and their energy spectral shape, we found sin^{2}2θ_{13} = 0.086 +/- 0.041 (stat) +/- 0.030 (syst) at Δm^2_{atm} = 2.4 x 10^{-3} eV^2.

hep-ex