Searcharxiv⌕ Search

arXiv subjects

Tuvia Gefen

Publications and source records attributed to Tuvia Gefen.

27 records · Page 2Linked to original sources

Achieving the ultimate precision limit in quantum NMR spectroscopy

The ultimate precision limit in estimating the Larmor frequency of $N$ unentangled rotating spins is well established, and is highly important for magnetometers, gyroscopes and many other sensors. However this limit assumes perfect, single addressing, measurements of the spins. This requirement is not practical in NMR spectroscopy, as well as other physical systems, where a weakly interacting external probe is used as a measurement device. Here we show that in the framework of quantum nano-NMR spectroscopy, in which these limitations are inherent, the ultimate precision limit is still achievable using control and a finely tuned measurement.

quant-ph↗

Overcoming resolution limits with quantum sensing

The field of quantum sensing explores the use of quantum phenomena to measure a broad range of physical quantities, of both static and time-dependent types. An important figure of merit for sensing time dependent signals is the spectral resolution, i.e. the ability to resolve two different frequencies. Here we study this problem, and develop new superresolution methods that rely on quantum features. We first formulate a general criterion for superresolution in quantum problems. Inspired by this, we show that quantum detectors can resolve two frequencies from incoherent segments of the signal, irrespective of their separation, in contrast to what is known about classical detection schemes. The main idea behind these methods is to overcome the vanishing distinguishability in resolution problems by nullifying the projection noise.

quant-ph↗

Limits on Spectral Resolution Measurements by Quantum Probes

The limits of frequency resolution in nano-NMR experiments have been discussed extensively in recent years. It is believed that there is a crucial difference between the ability to resolve a few frequencies and the precision of estimating a single one. Whereas the efficiency of single frequency estimation gradually increases with the square root of the number of measurements, the ability to resolve two frequencies is limited by the specific timescale of the signal and cannot be compensated for by extra measurements. Here we show theoretically and demonstrate experimentally that the relationship between these quantities is more subtle and both are only limited by the Cramér-Rao bound of a single frequency estimation.

quant-ph↗

Quantum spectroscopy of single spins assisted by a classical clock

Quantum spectroscopy with single two level systems has considerably improved our ability to detect weak signals. Recently it was realized that for classical signals, precision and resolution of quantum spectroscopy is limited mainly by coherence of the signal and stability of the clock used to measure time. The coherence time of the quantum probe, which can be significantly shorter, is not a major limiting factor in resolution measurements. Here, we address a similar question for spectroscopy of quantum signals, for example a quantum sensor is used to detect a single nuclear spin. We present and analyze a novel correlation spectroscopy technique with performance that is limited by the coherence time of the target spins and the stability of the clock.

quant-ph↗

Control methods for improved Fisher information with quantum sensing

Recently new approaches for sensing the frequency of time dependent Hamiltonians have been presented, and it was shown that the optimal Fisher information scales as $T^{4}.$ We present here our interpretation of this new scaling, where the relative phase is accumulated quadratically with time, and show that this can be produced by a variety of simple pulse sequences. Interestingly, this scaling has a limited duration, and we show that certain pulse sequences prolong the effect. The performance of these schemes is analyzed and we examine their relevance to state-of-the-art experiments. We analyze the $T^{3}$ scaling of the Fisher information which appears when multiple synchronized measurements are performed, and is the optimal scaling in the case of a finite coherence time.

quant-ph↗

Sub-millihertz magnetic spectroscopy with a nanoscale quantum sensor

Precise timekeeping is critical to metrology, forming the basis by which standards of time, length and fundamental constants are determined. Stable clocks are particularly valuable in spectroscopy as they define the ultimate frequency precision that can be reached. In quantum metrology, where the phase of a qubit is used to detect external fields, the clock stability is defined by the qubit coherence time, which determines the spectral linewidth and frequency precision. Here we demonstrate a quantum sensing protocol where the spectral precision goes beyond the sensor coherence time and is limited by the stability of a classical clock. Using this technique, we observe a precision in frequency estimation scaling in time $T$, as $T^{-3/2}$ for classical oscillating fields. The narrow linewidth magnetometer based on single spins in diamond is used to sense nanoscale magnetic fields with an intrinsic frequency resolution of 607 $μ$Hz, 8 orders of magnitude narrower than the qubit coherence time.

quant-ph↗

Refocusing two qubit gates with measurements for trapped ions

Dynamical decoupling techniques are the method of choice for increasing gate fidelities. While these methods have produced very impressive results in terms of decreasing local noise and increasing the fidelities of single qubit operations, dealing with the noise of two qubit gates has proven more challenging. The main obstacle is that the noise time scale is shorter than the two qubit gate itself so that refocusing methods do not work. We present a measurement and feedback based method to refocus two qubit gates which cannot be refocused by conventional methods. We analyze in detail this method for an error model which is relevant for trapped ions quantum information.

quant-ph↗

Parameter estimation with efficient photodetectors

Current parameter estimation techniques rely on photodetectors which have low brightness and thus are based on gathering averaged statistics. Recently it was claimed that perfect photodetction will change the nature of sensing algorithms and will increase sensing efficiency beyond the immediate effect of having larger collection efficiency. In this paper we bring up the observation that perfect photodetection implies Heisenberg scaling($\frac{1}{T}$) for parameter estimations. We analyze a specific example in detail.

quant-ph↗

Quantum Error-Correction-Enhanced Magnetometer Overcoming the Limit Imposed by Relaxation

When incorporated in quantum sensing protocols, quantum error correction can be used to correct for high frequency noise, as the correction procedure does not depend on the actual shape of the noise spectrum. As such, it provides a powerful way to complement usual refocusing techniques. Relaxation imposes a fundamental limit on the sensitivity of state of the art quantum sensors which cannot be overcome by dynamical decoupling. The only way to overcome this is to utilize quantum error correcting codes. We present a superconducting magnetometry design that incorporates approximate quantum error correction, in which the signal is generated by a two qubit Hamiltonian term. This two-qubit term is provided by the dynamics of a tunable coupler between two transmon qubits. For fast enough correction, it is possible to lengthen the coherence time of the device beyond the relaxation limit.

quant-ph↗