Searcharxiv⌕ Search

arXiv subjects

U. Dammalapati

Publications and source records attributed to U. Dammalapati.

15 recordsLinked to original sources

Two-dimensional beam profile monitor for the detection of alpha-emitting radioactive isotope beam

Ions with similar charge-to-mass ratios cannot be separated from existing beam profile monitors (BPMs) in nuclear facilities in which low-energy radioactive ions are produced due to nuclear fusion reactions. In this study, we developed a BPM using a microchannel plate and a charge-coupled device to differentiate the beam profiles of alpha-decaying radioactive isotopes from other ions (reaction products) produced in a nuclear reaction. This BPM was employed to optimize the low-energy radioactive francium ion (Fr+) beam developed at the Cyclotron and Radioisotope Center (CYRIC), Tohoku University, for electron permanent electric dipole moment (e-EDM) search experiments using Fr atoms. We demonstrated the performance of the BPM by separating the Fr+ beam from other reaction products produced during the nuclear fusion reaction of an oxygen (18O) beam and gold (197Au) target. However, as the mass of Au is close to that of Fr, separating the ions of these elements using a mass filter is a challenge, and a dominant number of Au+ renders the Fr+ beam profile invisible when using a typical BPM. Therefore, by employing the new BPM, we could successfully observe the Fr+ beam and other ion beams distinctly by measuring the alpha decay of Fr isotopes. This novel technique to monitor the alpha-emitting radioactive beam covers a broad range of lifetimes, for example, from approximately 1 s to 10 min, and can be implemented for other alpha-emitter beams utilized for medical applications.

physics.ins-det↗

Magic and tune-out wavelengths for atomic francium

The frequency dependent polarizabilities of the francium atom are calculated from the available data of energy levels and transition rates. Magic wavelengths for the state insensitive optical dipole trapping are identified from the calculated light shifts of the $7s~^2S_{1/2}$, $7p~^2P_{1/2, 3/2}$ and $8s~^{2}S_{1/2}$ levels of the $7s~^{2}S_{1/2}-7p~^{2}P_{1/2,3/2}$ and $7s~^{2}S_{1/2}-8s~^{2}S_{1/2}$ transitions, respectively. Wavelengths in the ultraviolet, visible and near infrared region is identified that are suitable for cooling and trapping. Magic wavelengths between 600-700~nm and 700-1000~nm region, which are blue and red detuned with the $7s-7p$ and $7s-8s$ transitions are feasible to implement as lasers with sufficient power are available. In addition, we calculated the tune-out wavelengths where the ac polarizability of the ground $7s~^{2}S_{1/2}$ state in francium is zero. These results are beneficial as laser cooled and trapped francium has been in use for fundamental symmetry investigations like searches for an electron permanent electric dipole moment in an atom and for atomic parity non-conservation.

physics.atom-ph↗

Lifetime determination of the 5d$^{2}$~$^{3}$F$_{2}$ state in barium using trapped atoms

Magneto-optically trapped atoms enable the determination of lifetimes of metastable states and higher lying excited states like the $\rm{5d^{2}~^{3}F_{2}}$ state in barium. The state is efficiently populated by driving strong transitions from metastable states within the cooling cycle of the barium MOT. The lifetime is inferred from the increase of MOT fluorescence after the transfer of up to $30\,\%$ of the trapped atoms to this state. The radiative decay of the $\rm{5d^{2}~^{3}F_{2}}$ state cascades to the cooling cycle of the MOT with a probability of $96.0(7)\,\%$ corresponding to a trap loss of $4.0(7)\,\%$ and its lifetime is determined to $\rm{160(10)~μs}$. This is in good agreement with the theoretically calculated lifetime of $\rm{190~μs}$ [J. Phys. B, {\bf 40}, 227 (2007)]. The determined loss of $4.0(7)\,\%$ from the cooling cycle is compared with the theoretically calculated branching ratios. This measurement extends the efficacy of trapped atoms to measure lifetimes of higher, long-lived states and validate the atomic structure calculations of heavy multi-electron systems.

physics.atom-ph↗

Absolute frequency measurement of the 7s$^2$ $^1$S$_0$ $-$ 7s7p $^{1}$P$_1$ transition in $^{225}$Ra

Transition frequencies were determined for transitions in Ra in an atomic beam and for reference lines in Te$_2$ molecules in a vapor cell. The absolute frequencies were calibrated against a GPS stabilized Rb-clock by means of an optical frequency comb. The 7s$^2\,^1$S$_0$(F = 1/2)-7s7p$\,^1$P$_1$(F = 3/2) transition in $^{225}$Ra was determined to be $621\,042\,124(2)\,$MHz. The measurements provide input for designing efficient and robust laser cooling of Ra atoms in preparation of a search for a permanent electric dipole moment in Ra isotopes.

physics.atom-ph↗

Scattering lengths of calcium and barium isotopes

We have calculated the s-wave scattering length of all the even isotopes of calcium (Ca) and barium (Ba), in order to investigate the prospect of Bose-Einstein condensation (BEC). For Ca we have used an accurate molecular potential based on detailed spectroscopic data. Our calculations show that Ca does not provide other isotopes alternative to the recently Bose condensed 40Ca that suffers strong losses because of a very large scattering length. For Ba we show by using a model potential that the even isotopes cover a broad range of scattering lengths, opening the possibility of BEC for at least one of the isotopes.

cond-mat.quant-gas↗

Isotope Shifts of the $6d\,^2$D$_{3/2}\,$ - $7p\,^2$P$_{1/2}\,$ Transition in Trapped Short-Lived $^{209-214}$Ra$^+$

Laser spectroscopy of short-lived radium isotopes in a linear Paul trap has been performed. The isotope shifts of the $6d\,^2$D$_{3/2}\,$ - $7p\,^2$P$_{1/2}\,$ transition in $^{209-214}$Ra$^+$ were measured, which are sensitive to the short range part of the atomic wavefunctions. The results are essential experimental input for improving the precision of atomic structure calculation. This is indispensable for parity violation in Ra$^+$ aiming at the determination of the weak mixing angle.

physics.atom-ph↗

A versatile and reliably re-usable ultrahigh vacuum viewport

We present a viewport for use in Ultra-high vacuum (UHV) based upon the preflattened solder seal design presented in earlier work, Cox et al. Rev. Sci. Inst. 74, 3185 (2003). The design features significant modifications to improve long term performance. The windows have been leak tested to less than 10^-10 atm cm^3/s . From atom number measurements in an optical dipole trap loaded from a vapor cell magneto-optical trap (MOT) inside a vacuum chamber accommodating these viewports, we measure a trap lifetime of 9.5s suggesting a pressure of around 10^-10 Torr limited by background Rubidium vapor pressure. We also present a simplified design where the UHV seal is made directly to a vacuum pipe

physics.ins-det↗

Magneto optical trapping of Barium

First laser cooling and trapping of the heavy alkaline earth element barium has been achieved based on the strong 6s$^2$ $^1$S$_0$ - 6s6p $^1$P$_1$ transition for the main cooling. Due to the large branching into metastable D-states several additional laser driven transitions are required to provide a closed cooling cycle. A total efficiency of $0.4(1) \cdot 10^{-2}$ for slowing a thermal atomic beam and capturing atoms into a magneto optical trap was obtained. Trapping lifetimes of more than 1.5 s were observed. This lifetime is shortened at high laser intensities by photo ionization losses. The developed techniques will allow to extend significantly the number of elements that can be optically cooled and trapped.

physics.atom-ph↗

Isotope shifts of 6s5d $^3$D-states in neutral Barium

Laser spectroscopy of the low lying $^1$P and $^3$D states in atomic barium has been performed. This work contributes substantially to the development of an effective laser cooling and trapping for heavy alkaline earth elements and aims in particular for a better understanding of the atomic wave function of these systems. Isotope shifts and hyperfine structures are ideal probes for the wave functions at the position of the nucleus. This is essential input for a theoretical evaluation of the sensitivity to fundamental symmetry breaking properties like permanent electric dipole moments. We report the first isotope shift measurements of the $^3$D$_{1,2}$-$^1$P$_1$ transitions. A deviation of the King plot from its expected behavior has been observed. Further we have optically resolved the hyperfine structure of the $^3$D$_{1,2}$ states.

physics.atom-ph↗

Development of a thermal ionizer as ion catcher

An effective ion catcher is an important part of a radioactive beam facility that is based on in-flight production. The catcher stops fast radioactive products and emits them as singly charged slow ions. Current ion catchers are based on stopping in He and H$_2$ gas. However, with increasing intensity of the secondary beam the amount of ion-electron pairs created eventually prevents the electromagnetic extraction of the radioactive ions from the gas cell. In contrast, such limitations are not present in thermal ionizers used with the ISOL production technique. Therefore, at least for alkaline and alkaline earth elements, a thermal ionizer should then be preferred. An important use of the TRI$μ$P facility will be for precision measurements using atom traps. Atom trapping is particularly possible for alkaline and alkaline earth isotopes. The facility can produce up to 10$^9$ s$^{-1}$ of various Na isotopes with the in-flight method. Therefore, we have built and tested a thermal ionizer. An overview of the operation, design, construction, and commissioning of the thermal ionizer for TRI$μ$P will be presented along with first results for $^{20}$Na and $^{21}$Na.

nucl-ex↗

Production and trapping of radioactive atoms at the TRI\muP facility

The structures for the TRI$μ$P facility have been completed and commissioned. At the facility radioactive nuclides are produced to study fundamental interactions and symmetries. An important feature is the possibility to trap radioactive atoms in order to obtain and hold a pure substrate-free sample for precision measurements. In the TRI$μ$P facility a production target is followed by a magnetic separator, where radioactive isotopes are produced in inverse reaction kinematics. Separation up to 99.95% could be achieved for $^{21}$Na. A novel transmitting thermal ionizing device was developed to stop the energetic isotopes. Some 50% of stopped $^{21}$Na could be extracted and transported as low energy singly charged ions into a radio frequency quadrupole cooler and buncher with 35% transmission efficiency. The ions are transported lossless via a drift tube and a low energy electrostatic beam line into the experimental setup. Such ions can be neutralized on hot metal foils and the resulting atoms can be stored in a magneto-optical trap. The functioning of that principle was demonstrated with stable Na extracted from the thermal ionizer, radioactive beams will follow next.

nucl-ex↗

Coherent Dark Resonances in Atomic Barium

The observation of dark-resonances in the two-electron atom barium and their influence on optical cooling is reported. In heavy alkali earth atoms, i.e. barium or radium, optical cooling can be achieved using n^1S_0-n^1P_1 transitions and optical repumping from the low lying n^1D_2 and n^3D_{1,2} states to which the atoms decay with a high branching ratio. The cooling and repumping transition have a common upper state. This leads to dark resonances and hence make optical cooling less inefficient. The experimental observations can be accurately modelled by the optical Bloch equations. Comparison with experimental results allows us to extract relevant parameters for effective laser cooling of barium.

physics.atom-ph↗

Production of Radioactive Nuclides in Inverse Reaction Kinematics

Efficient production of short-lived radioactive isotopes in inverse reaction kinematics is an important technique for various applications. It is particularly interesting when the isotope of interest is only a few nucleons away from a stable isotope. In this article production via charge exchange and stripping reactions in combination with a magnetic separator is explored. The relation between the separator transmission efficiency, the production yield, and the choice of beam energy is discussed. The results of some exploratory experiments will be presented.

nucl-ex↗

Aspects of Cooling at the TRI$μ$P Facility

The Tri$μ$P facility at KVI is dedicated to provide short lived radioactive isotopes at low kinetic energies to users. It comprised different cooling schemes for a variety of energy ranges, from GeV down to the neV scale. The isotopes are produced using beam of the AGOR cyclotron at KVI. They are separated from the primary beam by a magnetic separator. A crucial part of such a facility is the ability to stop and extract isotopes into a low energy beamline which guides them to the experiment. In particular we are investigating stopping in matter and buffer gases. After the extraction the isotopes can be stored in neutral atoms or ion traps for experiments. Our research includes precision studies of nuclear $β$-decay through $β$-$ν$ momentum correlations as well as searches for permanent electric dipole moments in heavy atomic systems like radium. Such experiments offer a large potential for discovering new physics.

physics.atom-ph↗

Dual Magnetic Separator for TRI$μ$P

The TRI$μ$P facility, under construction at KVI, requires the production and separation of short-lived and rare isotopes. Direct reactions, fragmentation and fusion-evaporation reactions in normal and inverse kinematics are foreseen to produce nuclides of interest with a variety of heavy-ion beams from the superconducting cyclotron AGOR. For this purpose, we have designed, constructed and commissioned a versatile magnetic separator that allows efficient injection into an ion catcher, i.e., gas-filled stopper/cooler or thermal ionizer, from which a low energy radioactive beam will be extracted. The separator performance was tested with the production and clean separation of $^{21}$Na ions, where a beam purity of 99.5% could be achieved. For fusion-evaporation products, some of the features of its operation as a gas-filled recoil separator were tested.

nucl-ex↗