Searcharxiv⌕ Search

arXiv subjects

U. Hager

Publications and source records attributed to U. Hager.

27 records · Page 2Linked to original sources

Mass measurements of neutron-rich nuclei at JYFLTRAP

The JYFLTRAP mass spectrometer was used to measure the masses of neutron-rich nuclei in the region between N = 28 to N = 82 with uncertainties better than 10 keV. The impacts on nuclear structure and the r-process paths are reviewed.

nucl-ex↗

Q_EC values of the Superallowed beta Emitters 50Mn and 54Co

Using a new fast cleaning procedure to prepare isomerically pure ion samples, we have measured the beta-decay Q_EC values of the superallowed beta-emitters 50Mn and 54Co to be 7634.48(7) keV and 8244.54(10) keV, respectively, results which differ significantly from the previously accepted values. The corrected Ft values derived from our results strongly support new isospin-symmetry-breaking corrections that lead to a higher value of the up-down quark mixing element, Vud, and improved confirmation of the unitarity of the Cabibbo-Kobayashi-Maskawa matrix.

nucl-ex↗

Precise atomic masses of neutron-rich Br and Rb nuclei close to the r-process path

The Penning trap mass spectrometer JYFLTRAP, coupled to the Ion-Guide Isotope Separator On-Line (IGISOL) facility at Jyvaskyla, was employed to measure the atomic masses of neutron rich 85 to 92Br and 94 to 97Rb isotopes with a typical accuracy less than 10 keV. Discrepancies with the older data are discussed. Comparison to different mass models is presented. Details of nuclear structure, shell and subshell closures are investigated by studying the two-neutron separation energy and the shell gap energy.

nucl-ex↗

Precision mass measurements of radioactive nuclei at JYFLTRAP

The Penning trap mass spectrometer JYFLTRAP was used to measure the atomic masses of radioactive nuclei with an uncertainty better than 10 keV. The atomic masses of the neutron-deficient nuclei around the N = Z line were measured to improve the understanding of the rp-process path and the SbSnTe cycle. Furthermore, the masses of the neutron-rich gallium (Z = 31) to palladium (Z = 46) nuclei have been measured. The physics impacts on the nuclear structure and the r-process paths are reviewed. A better understanding of the nuclear deformation is presented by studying the pairing energy around A = 100.

nucl-ex↗

Magnetic field stabilization for high-accuracy mass measurements on exotic nuclides

The magnetic-field stability of a mass spectrometer plays a crucial role in precision mass measurements. In the case of mass determination of short-lived nuclides with a Penning trap, major causes of instabilities are temperature fluctuations in the vicinity of the trap and pressure fluctuations in the liquid helium cryostat of the superconducting magnet. Thus systems for the temperature and pressure stabilization of the Penning trap mass spectrometer ISOLTRAP at the ISOLDE facility at CERN have been installed. A reduction of the fluctuations by at least one order of magnitude downto dT=+/-5mK and dp=+/-50mtorr has been achieved, which corresponds to a relative frequency change of 2.7x10^{-9} and 1.5x10^{-10}, respectively. With this stabilization the frequency determination with the Penning trap only shows a linear temporal drift over several hours on the 10 ppb level due to the finite resistance of the superconducting magnet coils.

physics.ins-det↗

Separated Oscillatory Fields for High-Precision Penning Trap Mass Spectrometry

Ramsey's method of separated oscillatory fields is applied to the excitation of the cyclotron motion of short-lived ions in a Penning trap to improve the precision of their measured mass. The theoretical description of the extracted ion-cyclotron-resonance line shape is derived out and its correctness demonstrated experimentally by measuring the mass of the short-lived $^{38}$Ca nuclide with an uncertainty of $1.6\cdot 10^{-8}$ using the ISOLTRAP Penning trap mass spectrometer at CERN. The mass value of the superallowed beta-emitter $^{38}$Ca is an important contribution for testing the conserved-vector-current hypothesis of the electroweak interaction. It is shown that the Ramsey method applied to mass measurements yields a statistical uncertainty similar to that obtained by the conventional technique ten times faster.

nucl-ex↗

Q-values of the Superallowed beta-Emitters 26m-Al, 42-Sc and 46-V and their impact on V_ud and the Unitarity of the CKM Matrix

The beta-decay Q_EC-values of the superallowed beta emitters 26m-Al, 42-Sc and 46-V have been measured with a Penning trap to a relative precision of better than 8x10^-9. Our result for 46-V, 7052.72(31) keV, confirms a recent measurement that differed significantly from the previously accepted reaction-based Q_EC-value. However, our results for 26m-Al and 42-Sc, 4232.83(13) keV and 6426.13(21) keV, are consistent with previous reaction-based values. By eliminating the possibility of a systematic difference between the two techniques, this result demonstrates that no significant shift in the deduced value of V_ud should be anticipated.

nucl-ex↗

An Ion Guide for the Production of a Low Energy Ion Beam of Daughter Products of $α$-Emitters

A new ion guide has been modeled and tested for the production of a low energy ($\approx$ 40 kV) ion beam of daughter products of alpha-emitting isotopes. The guide is designed to evacuate daughter recoils originating from the $α$-decay of a $^{233}$U source. The source is electroplated onto stainless steel strips and mounted along the inner walls of an ion guide chamber. A combination of electric fields and helium gas flow transport the ions through an exit hole for injection into a mass separator. Ion guide efficiencies for the extraction of $^{229}$Th$^{+}$ (0.06%), $^{221}$Fr$^{+}$ (6%), and $^{217}$At$^{+}$ (6%) beams have been measured. A detailed study of the electric field and gas flow influence on the ion guide efficiency is described for two differing electric field configurations.

nucl-ex↗

Q-value of the superallowed beta decay of Ga-62

Masses of the radioactive isotopes 62Ga, 62Zn and 62Cu have been measured at the JYFLTRAP facility with a relative precision of better than 18 ppb. A Q_EC value of (9181.07 +- 0.54) keV for the superallowed decay of 62Ga is obtained from the measured cyclotron frequency ratios of 62Ga-62Zn, 62Ga-62Ni and 62Zn-62Ni ions. The resulting Ft-value supports the validity of the conserved vector current hypothesis (CVC). The mass excess values measured were (-51986.5 +-1.0) keV for 62Ga, (-61167.9 +- 0.9) keV for 62Zn and (-62787.2 +- 0.9) keV for 62Cu.

nucl-ex↗