SearcharxivSearch

arXiv subjects

U. Werthenbach

Publications and source records attributed to U. Werthenbach.

7 recordsLinked to original sources

On image reconstruction with the two-dimensional interpolating resistive readout structure of the Virtual-Pixel detector

The two-dimensional interpolating readout concept of the Virtual-Pixel detector (ViP detector) goes along with an enormous reduction of electronic channels compared to pure pixel devices. However, the special concept of the readout structure demands for adequate position reconstruction methods. Theoretical considerations reflecting the choice and the combination of linear algorithms with emphasis on correct position reconstruction and spatial resolution are presented. A subsequent two-dimensional coordinate transformation further improves the image response of the system. Measured images show how far the theoretical predictions of the simulations can be verified and to what extent they can be used to improve the position reconstruction.

physics.ins-det

Gas gain and signal length measurements with a triple-GEM at different pressures of Ar-, Kr- and Xe-based gas mixtures

We investigate the gas gain behaviour of a triple-GEM configuration in gas mixtures of argon, krypton and xenon with ten and thirty percent of carbon dioxide at pressures between 1 and 3 bar. Since the signal widths affect the dead time behaviour of the detector we present signal length measurements to evaluate the use of the triple-GEM in time-resolved X-ray imaging.

physics.ins-det

Investigation of the performance of an optimised MicroCAT, a GEM and their combination by simulations and current measurements

A MicroCAT (Micro Compteur A Trous) structure which is used for avalanche charge multiplication in gas filled radiation detectors has been optimised with respect to maximum electron transparency and minimum ion feedback. We report on the charge transfer behaviour and the achievable gas gain of this device. A three-dimensional electron and ion transfer simulation is compared to results derived from electric current measurements. Similarly, we present studies of the charge transfer behaviour of a GEM (Gas Electron Multiplier) by current measurements and simulations. Finally, we investigate the combination of the MicroCAT and the GEM by measurements with respect to the performance at different voltage settings, gas mixtures and gas pressures.

physics.ins-det

Studies of aging and HV break down problems during development and operation of MSGC and GEM detectors for the Inner Tracking System of HERA-B

The results of five years of development of the inner tracking system of the HERA-B experiment and first experience from the data taking period of the year 2000 are reported. The system contains 184 chambers, covering a sensitive area of about 20 * 20 cm2 each. The detector is based on microstrip gas counters (MSGCs) with diamond like coated (DLC) glass wafers and gas electron multipliers (GEMs). The main problems in the development phase were gas discharges in intense hadron beams and aging in a high radiation dose environment. The observation of gas discharges which damage the electrode structure of the MSGC led to the addition of the GEM as a first amplification step. Spurious sparking at the GEM cannot be avoided completely. It does not affect the GEM itself but can produce secondary damage of the MSGC if the electric field between the GEM and the MSGC is above a threshold depending on operation conditions. We observed that aging does not only depend on the dose but also on the spot size of the irradiated area. Ar-DME mixtures had to be abandoned whereas a mixture of 70% Ar and 30% CO2 showed no serious aging effects up to about 40 mC/cm deposited charge on the anodes. X-ray measurements indicate that the DLC of the MSGC is deteriorated by the gas amplification process. As a consequence, long term gain variations are expected. The Inner Tracker has successfully participated in the data taking at HERA-B during summer 2000.

hep-ex

Properties of Groove Chambers

Groove chambers with different pitch and gap height have been tested. Gas amplifications of the order of a few times 10$^{3}$ have been obtained. Combining a groove structure with a GEM pre-amplification foil a gas gain of 10$^{5}$ was reached. The device is robust and can be produced at low cost in large sizes by a laser technique.

nucl-ex

Carbon Coated Gas Electron Multipliers

Gas electron multipliers (GEMs) have been overcoated with a high resistivity 10e14 - 10e15 Ohms / square amorphous carbon layer. The coating avoids charging up of the holes and provides a constant gain immediately after switching on independent of the rate. The gain uniformity across the GEM is improved. Coating opens the possibility to produce thick GEMs of very high gain.

physics.ins-det

An optical readout for a fibre tracker

The performance of 16 and 64 channel photomultipliers coupled to scintillating fibres has been tested. The devices are sensitive to single photoelectrons, show little gain losses for magnetic fields up to 100 Gauss and have moderate optical cross-talk. The maximum channel to channel gain variations reach a factor two for the 16 channel version and a factor of four for the 64 channel PM. The measurements and simulations indicate that the photomultipliers are well suited for the light detection in fibre trackers.

physics.ins-det