Searcharxiv⌕ Search

arXiv subjects

Ugo Lomoio

Publications and source records attributed to Ugo Lomoio.

7 recordsLinked to original sources

BiMa-ECGSR: reconstructing the 12-lead ECG from reduced lead sets with bidirectional state-space models

Wearables and monitors record few electrocardiogram (ECG) leads; most diagnostic tools assume 12 leads. BiMa-ECGSR reconstructs the 12-lead ECG from reduced lead sets with a bidirectional Mamba state-space encoder--decoder, as regression (BiMa-SR) or diffusion (DiBiMa-SR). Models were trained on PTB-XL for six input sets (I; II; I+II; I+II+V1; I+II+V2; I+II+V1+V4), see only the measured leads at inference, and were tested on the PTB-XL test fold (2,198 records) and two external cohorts (Georgia, 10,275 records; Chapman-Shaoxing/Ningbo, 43,559). From lead II alone, the pooled median Pearson correlation (PCC) over the 11 predicted leads was 0.914 on PTB-XL, against 0.784 for a least-squares linear filter (lead I: 0.906 against 0.789). As limb leads are exactly derivable from I and II, multi-lead inputs were compared on predicted chest leads: 0.939 against 0.849 for I+II and 0.979 against 0.962 for I+II+V1+V4. BiMa-SR exceeded the linear comparator in all 18 configuration--cohort pairs (by 0.012--0.136), a margin that shrank as chest leads were added. From lead II, regression was more accurate than diffusion (DiBiMa-SR: 0.903 one-step, 0.862 with six DDIM steps). A 12-lead classifier trained only on real ECGs reached a superclass macro AUROC of 0.912 on real PTB-XL ECGs, 0.843 on reconstructions from lead II and 0.908 from I+II+V1+V4; externally, reconstructions from three or four leads scored within 0.004 of real ECGs. BiMa-SR (2.68\,M parameters) takes 45.8 ms per 10-s record on a GPU. Reconstruction makes reduced-lead recordings usable by 12-lead tools; it cannot add information absent from the measured leads.

cs.LG↗

scHFBiMamba: a bidirectional Mamba autoencoder for cardiac disease-state classification from single-nucleus RNA-seq data

To evaluate whether a compact bidirectional state-space autoencoder improves joint classification of species, cell type, and disease state from single-nucleus RNA-sequencing profiles in heart failure (HF), while yielding interpretable gene attributions. Building on the dense denoising autoencoder (DAE) and MLP framework of Ruz Jurado et al., we developed scHFBiMamba, combining a bidirectional Mamba autoencoder (BiMambaAE) with an MLP head. BiMambaAE maps 16,545-gene profiles to 350-dimensional latent representations using 13.2M parameters, about 14.6-fold fewer than the dense DAE (192.9M). We compared six encoder-classifier configurations on 38,275 held-out cardiac nuclei using McNemar tests with Benjamini-Hochberg correction, and assessed nine classifiers on frozen representations. Biological relevance was evaluated by comparing SHAP-derived differentially explained genes with differentially expressed genes against curated HF-related Gene Ontology keywords. BiMambaAE+MLP achieved the highest aggregate F1: pooled macro-F1 across 13 outputs was 0.966 versus 0.957 for DAE+MLP, and the mean category macro-F1 was 0.977 versus 0.970. It significantly improved cell-type and disease-state accuracy (adjusted p=7.1e-3 and p=4.8e-6, respectively), with species F1 of 1.000. SHAP-derived differentially explained genes achieved a pathway-enrichment benchmark F1 of 0.105 versus 0.053 for differentially expressed genes. Compact bidirectional state-space autoencoders can outperform substantially larger dense autoencoders for joint cardiac transcriptomic classification while reducing parameters. scHFBiMamba enables accurate multi-task prediction and hypothesis-generating gene-level interpretation. Code: https://github.com/UgoLomoio/scHFBiMamba.

cs.LG↗

A Usable GAN-Based Tool for Synthetic ECG Generation in Cardiac Amyloidosis Research

Cardiac amyloidosis (CA) is a rare and underdiagnosed infiltrative cardiomyopathy, and available datasets for machine-learning models are typically small, imbalanced and heterogeneous. This paper presents a Generative Adversarial Network (GAN) and a graphical command-line interface for generating realistic synthetic electrocardiogram (ECG) beats to support early diagnosis and patient stratification in CA. The tool is designed for usability, allowing clinical researchers to train class-specific generators once and then interactively produce large volumes of labelled synthetic beats that preserve the distribution of minority classes.

cs.LG↗

Kolmogorov Arnold Network Autoencoder in Medicine

Deep learning neural networks architectures such Multi Layer Perceptrons (MLP) and Convolutional blocks still play a crucial role in nowadays research advancements. From a topological point of view, these architecture may be represented as graphs in which we learn the functions related to the nodes while fixed edges convey the information from the input to the output. A recent work introduced a new architecture called Kolmogorov Arnold Networks (KAN) that reports how putting learnable activation functions on the edges of the neural network leads to better performances in multiple scenarios. Multiple studies are focusing on optimizing the KAN architecture by adding important features such as dropout regularization, Autoencoders (AE), model benchmarking and last, but not least, the KAN Convolutional Network (KCN) that introduced matrix convolution with KANs learning. This study aims to benchmark multiple versions of vanilla AEs (such as Linear, Convolutional and Variational) against their Kolmogorov-Arnold counterparts that have same or less number of parameters. Using cardiological signals as model input, a total of five different classic AE tasks were studied: reconstruction, generation, denoising, inpainting and anomaly detection. The proposed experiments uses a medical dataset \textit{AbnormalHeartbeat} that contains audio signals obtained from the stethoscope.

cs.LG↗

E-ABIN: an Explainable module for Anomaly detection in BIological Networks

The increasing availability of large-scale omics data calls for robust analytical frameworks capable of handling complex gene expression datasets while offering interpretable results. Recent advances in artificial intelligence have enabled the identification of aberrant molecular patterns distinguishing disease states from healthy controls. Coupled with improvements in model interpretability, these tools now support the identification of genes potentially driving disease phenotypes. However, current approaches to gene anomaly detection often remain limited to single datasets and lack accessible graphical interfaces. Here, we introduce E-ABIN, a general-purpose, explainable framework for Anomaly detection in Biological Networks. E-ABIN combines classical machine learning and graph-based deep learning techniques within a unified, user-friendly platform, enabling the detection and interpretation of anomalies from gene expression or methylation-derived networks. By integrating algorithms such as Support Vector Machines, Random Forests, Graph Autoencoders (GAEs), and Graph Adversarial Attributed Networks (GAANs), E-ABIN ensures a high predictive accuracy while maintaining interpretability. We demonstrate the utility of E-ABIN through case studies of bladder cancer and coeliac disease, where it effectively uncovers biologically relevant anomalies and offers insights into disease mechanisms.

cs.LG↗

ExDiff: A Framework for Simulating Diffusion Processes on Complex Networks with Explainable AI Integration

Understanding and controlling diffusion processes in complex networks is critical across domains ranging from epidemiology to information science. Here, we present ExDiff, an interactive and modular computational framework that integrates network simulation, graph neural networks (GNNs), and explainable artificial intelligence (XAI) to model and interpret diffusion dynamics. ExDiff combines classical compartmental models with deep learning techniques to capture both the structural and temporal characteristics of diffusion across diverse network topologies. The framework features dedicated modules for network analysis, neural modeling, simulation, and interpretability, all accessible via an intuitive interface built on Google Colab. Through a case study of the Susceptible Infectious Recovered Vaccinated Dead (SIRVD) model, we demonstrate the capacity to simulate disease spread, evaluate intervention strategies, classify node states, and reveal the structural determinants of contagion through XAI techniques. By unifying simulation and interpretability, ExDiff provides a powerful, flexible, and accessible platform for studying diffusion phenomena in networked systems, enabling both methodological innovation and practical insight.

cs.SI↗

DCAE-SR: Design of a Denoising Convolutional Autoencoder for reconstructing Electrocardiograms signals at Super Resolution

Electrocardiogram (ECG) signals play a pivotal role in cardiovascular diagnostics, providing essential information on the electrical activity of the heart. However, the inherent noise and limited resolution in ECG recordings can hinder accurate interpretation and diagnosis. In this paper, we propose a novel model for ECG super resolution (SR) that uses a DNAE to enhance temporal and frequency information inside ECG signals. Our approach addresses the limitations of traditional ECG signal processing techniques. Our model takes in input 5-second length ECG windows sampled at 50 Hz (very low resolution) and it is able to reconstruct a denoised super-resolution signal with an x10 upsampling rate (sampled at 500 Hz). We trained the proposed DCAE-SR on public available myocardial infraction ECG signals. Our method demonstrates superior performance in reconstructing high-resolution ECG signals from very low-resolution signals with a sampling rate of 50 Hz. We compared our results with the current deep-learning literature approaches for ECG super-resolution and some non-deep learning reproducible methods that can perform both super-resolution and denoising. We obtained current state-of-the-art performances in super-resolution of very low resolution ECG signals frequently corrupted by ECG artifacts. We were able to obtain a signal-to-noise ratio of 12.20 dB (outperforms previous 4.68 dB), mean squared error of 0.0044 (outperforms previous 0.0154) and root mean squared error of 4.86% (outperforms previous 12.40%). In conclusion, our DCAE-SR model offers a robust (to artefact presence), versatile and explainable solution to enhance the quality of ECG signals. This advancement holds promise in advancing the field of cardiovascular diagnostics, paving the way for improved patient care and high-quality clinical decisions

eess.SP↗