SearcharxivSearch

arXiv subjects

V. Alcayne

Publications and source records attributed to V. Alcayne.

At least 19 recordsLinked to original sources

Improved $^{94}$Mo neutron resonance parameters from neutron capture and transmission measurements at n_TOF and GELINA

We report high-resolution measurements of the $^{94}\mathrm{Mo}(\mathrm{n},\gamma)^{95}\mathrm{Mo}$ cross section in the neutron energy range from a few eV up to about 250 keV, performed at the n_TOF facility (CERN), and of the $^{94}\mathrm{Mo}(\mathrm{n},\mathrm{tot})$ cross section up to 32 keV, measured at GELINA (JRC Geel). A combined R-matrix analysis of capture and transmission data yields significantly improved neutron-resonance parameters for $^{94}$Mo. A total of 186 resonances were observed in this analysis of which 127 reported here for the first time. The resulting Maxwellian-averaged cross section at stellar temperatures relevant to the slow neutron-capture process (s-process) is approximately 25% lower than previous evaluations and literature values. To assess the astrophysical impact of the revised cross section, we performed s-process nucleosynthesis calculations for low-mass asymptotic giant branch stars. Despite the substantial reduction in the $^{94}\mathrm{Mo}(\mathrm{n},\gamma)^{95}\mathrm{Mo}$ rate, the final yields vary by only 3-4%. This demonstrates that the isotopic budget of $^{94}$Mo in AGB stars is primarily governed by the branching flow at $^{94}\mathrm{Nb}$ rather than by the neutron-capture destruction on $^{94}$Mo itself. The new cross section thus helps disentangle nuclear cross-section uncertainties from branching-flow effects in the s-process production of $^{94}$Mo.

nucl-ex

Energy-differential measurement of the $^{\mathrm{nat}}$C(n,p) and $^{\mathrm{nat}}$C(n,d) reactions at the n_TOF facility at CERN

Energy-differential cross section of the $^{\mathrm{nat}}$C(n,p) and $^{\mathrm{nat}}$C(n,d) reactions was measured at the neutron time of flight facility n_TOF at CERN. The measurement was performed in the first experimental area (EAR1; flight path of 182.5 m). Two position-sensitive $\Delta E$-$E$ silicon telescopes were used. Two naturally occurring carbon isotopes, $^{12}$C and $^{13}$C, contribute to the reactions on natural carbon, with the (n,p) reaction threshold at 13.7 MeV and the (n,d) threshold at 14.9 MeV (determined by the $^{12}$C isotope for both reactions). This paper provides the details of the analysis leading to the final results published previously as a Letter. The cross section results are reported up to 25 MeV. During the data analysis the population of the excited states in the daughter nuclei $^{11}$B, $^{12}$B, $^{13}$B had to be considered, requiring the adoption of the branching ratios and angular distributions of the emitted particles from an external source of information. TALYS-2.0 calculations were used as the main source and an in-depth analysis of the model-related uncertainties was performed. The n_TOF results are largely inconsistent with the major evaluation libraries. On the other hand, an unexpected agreement is found with TALYS-2.0 calculations. Specifically, the obtained cross section for the (n,p) reaction is significantly higher than in the available evaluations, fully supporting the earlier finding from an integral measurement at n_TOF.

nucl-ex

First $^{94}$Nb($n,\gamma$) Measurement: Constraining the Nucleosynthetic Origin of $^{94}$Mo in Presolar Grains

Isotopic measurements of presolar silicon carbide grains from dying stars have revealed a puzzling overabundance of $^{94}$Mo that stellar nucleosynthesis models have failed to reproduce for two decades. This discrepancy challenged our understanding of the slow neutron-capture process ($s$-process) that forges approximately half of the elements heavier than iron. The key uncertainty lies at $^{94}$Nb, a radiactive branching point where competition between neutron capture and beta decay governs the $^{94}$Mo production, yet the neutron-capture cross section had never been measured. Here we report the first experimental determination of the $^{94}$Nb(n,$\gamma$)$^{95}$Nb cross section important for Mo isotopic abundances. The measurement was enabled by a coordinated effort involving high-purity target preparation at Institute of Solid State and Materials Research (IFW) Dresden, radioactive sample production at the Institut Laue-Langevin (ILL) Grenoble, radiochemical characterization at Paul Scherrer Institute (PSI) Villigen, and the Time-of-Flight CERN n$\_$TOF facility using for the first time segmented total-energy detectors. Incorporation of the resulting Maxwellian-averaged cross section into fully coupled nucleosynthesis models of low-mass asymptotic giant branch (AGB) stars brings them into agreement with the presolar grain data. These results remove a major nuclear-physics input uncertainty at the $^{94}$Nb branching point and provide a firmer foundation for understanding the origin of $^{94}$Mo in the solar system.

nucl-ex

Measurement of the $^\text{nat}$C(n,p) and $^\text{nat}$C(n,d) reactions from n_TOF at CERN

The energy dependence of the cross section of the (n,p) and (n,d) reactions on $^\text{nat}$C has been studied for the first time at the n_TOF facility at CERN, from the particle detection threshold up to 25 MeV. The measurement was performed with two telescopes made of position-sensitive silicon $\Delta E$-$E$ detectors, covering the angular range from 20{\deg} to 140{\deg}. A detector efficiency has been determined by means of Monte Carlo simulations of the experimental setup. Various assumptions on the angular distributions and branching ratios of the excited levels of the residual $^{11}$B, $^{12}$B, $^{13}$B nuclei were considered. In particular, theoretical calculations based on the TALYS-2.0 code were used and the systematic uncertainties in the analysis results were determined from the variations in these distributions. The n_TOF data on the (n,p) and (n,d) reaction on carbon are characterized by a higher accuracy and wider energy range than currently available in literature. A comparison with current evaluations from different libraries reveals a rather significant disagreement with the n_TOF results, while a remarkable agreement is observed with the prediction of TALYS-2.0 for this light element.

nucl-ex

New measurement of $^{50}$Cr and $^{53}$Cr (n,$\gamma$) cross sections at n_TOF: a call for chromium nuclear data revision

$^{50}$Cr and $^{53}$Cr are very relevant in criticality safety benchmarks related to nuclear reactors. The discrepancies of up to 30% between the neutron capture cross section evaluations have an important effect on the $k_{eff}$ and $k_{\infty}$ in criticality benchmarks particularly sensitive to chromium. In this work, the $^{50,53}$Cr(n,$\gamma$) cross sections are to be determined between 1 and 100 keV with an 8-10% accuracy following the requirements of the NEA High Priority Request List (HPRL) to solve the current discrepancies. We have measured these reactions by the time-of-flight technique at the EAR1 experimental area of the n_TOF facility, using an array of four C$_6$D$_6$ detectors with very low neutron sensitivity. The highly-enriched samples used are significantly thinner than in previous measurements, thus minimizing the multiple-scattering effects. We have produced, and analysed with the R-matrix analysis code SAMMY, capture yields featuring 33 resonances of $^{50}$Cr and 51 of $^{53}$Cr with an accuracy between 5% and 9%, hence fulfilling the requirements made by the NEA. The differential and integral cross sections have been compared to previous data and evaluations. The new measured $^{50,53}$Cr(n,$\gamma$) cross sections provide a valuable input for upcoming evaluations, which are deemed necessary given that the results presented herein do not support the increase in both cross sections proposed in the recent INDEN evaluation.

nucl-ex

Characterisation of the neutron beam in the n_TOF-EAR2 experimental area at CERN following the spallation target upgrade

The n_TOF facility at CERN has undergone a major upgrade after the installation of a new spallation target, designed to improve the features of both neutron beamlines at the experimental areas 1 and 2 (EAR1 and EAR2) and the commissioning of a new experimental area (NEAR). Due to improved coupling of the spallation target with the EAR2 beamline, the upgrade resulted in a significantly increased neutron flux and improved neutron energy resolution. This paper presents the results of the commissioning phase that followed to characterise the EAR2 neutron beamline and validate the FLUKA Monte Carlo simulations of the facility. The main features of the neutron beam, namely the neutron flux, spatial profile and energy resolution, are evaluated and compared to the previous target. The neutron flux presents a general increase of 20% below 1 eV, 40% between 1 eV and 100 keV and 50% between 100 keV and 10 MeV. The measured width of the beam profile was 3 cm (FWHM) at the reference position for neutron capture measurements. The energy resolution with the new spallation target shows a significant improvement compared to the previous one. Moreover, FLUKA Monte Carlo simulations present a good agreement with the measured neutron flux and profile within uncertainties, and a remarkable reproduction of the energy resolution.

physics.ins-det

Neutron capture measurements for s-process nucleosynthesis; A review about CERN n_TOF developments and contributions

This article presents a review about the main CERN n\_TOF contributions to the field of neutron-capture experiments of interest for $s$-process nucleosynthesis studies over the last 25 years, with special focus on the measurement of radioactive isotopes. A few recent capture experiments on stable isotopes of astrophysical interest are also discussed. Results on $s$-process branching nuclei are appropriate to illustrate how advances in detection systems and upgrades in the facility have enabled increasingly challenging experiments and, as a consequence, have led to a better understanding and modeling of the $s$-process mechanism of nucleosynthesis. New endeavors combining radioactive-ion beams from ISOLDE for the production of radioisotopically pure samples for activation experiments at the new NEAR facility at n\_TOF are briefly discussed. On the basis of these new exciting results, also current limitations of state-of-the-art TOF and activation techniques will be depicted, thereby showing the pressing need for further upgrades and enhancements on both facilities and detection systems. A brief account of the potential technique based on inverse kinematics for direct neutron-capture measurements is also presented.

nucl-ex

$\beta$-delayed neutron spectroscopy of $^{85, 86}$As with MONSTER at IGISOL

The $\beta$-delayed neutron emission in the $^{85, 86}$As $\beta$-decays has been measured at the Ion Guide Isotope Separator On Line facility of the Accelerator Laboratory of the University of Jyv\"askyl\"a. The complete $\beta$-decays have been studied with a complex setup that consists of a plastic scintillator for $\beta$-particles, MONSTER -- the MOdular Neutron time-of-flight SpectromeTER -- for neutrons, and a high-purity germanium and four LaBr$_3$ crystals for $\gamma$-rays. The $\beta$-delayed neutron energy distributions have been determined by unfolding the time-of-flight spectra with an innovative methodology based on the iterative Bayesian unfolding method and accurate Monte Carlo simulations. The results obtained for $^{85}$As are in excellent agreement with the existing evaluated data, validating the proposed methodology. In the case of $^{86}$As, a stronger neutron intensity at higher energies than previously predicted is discovered.

nucl-ex

Radiative neutron capture cross section of $^{242}$Pu measured at n_TOF-EAR1 in the unresolved resonance region up to 600 keV

Accurate neutron capture cross sections are essential for the design and operation of fast reactors using MOX fuels. For $^{242}$Pu, the Nuclear Energy Agency (NEA) recommends 8--12% accuracy in the fast energy region (2--500 keV), compared to the current uncertainty of 35%. Moreover, integral experiments and previous measurements suggest the evaluated $^{242}$Pu(n,$\gamma$) cross section is overestimated, particularly in the JEFF-3.3 library, which shows a 14% overestimation between 1 keV and 1 MeV. Recent measurements from LANSCE reported a 20--30% reduction in the 1--40 keV range relative to evaluations. To solve these discrepancies, the $^{242}$Pu(n,$\gamma$) cross section was measured from 1 to 600 keV at CERN n_TOF-EAR1 facility using a 95(4) mg $^{242}$Pu target, enriched to 99.959%. Gamma rays from neutron capture were detected with an array of C$_6$D$_6$ scintillators and a novel application of the Pulse Height Weighting Technique was employed. The resulting cross section presents a systematic uncertainty between 8 and 12%, reducing the current uncertainties of 35\% and achieving the accuracy requested by the NEA. Analysis using FITACS produced average resonance parameters, consistent with the analysis of the resolved resonance region. Our data align well with Wisshak and Kaeppeler, and are 10--14\% lower than JEFF-3.3 in the 1--250 keV range, helping to achieve consistency with integral benchmarks. At higher energies, our results are in reasonable agreement with ENDF/B-VIII.1 and JEFF-3.3. In contrast, DANCE results appear to underestimate the cross section by a factor of 2--3 above a few keV.

nucl-ex

Towards a new generation of solid total-energy detectors for neutron-capture time-of-flight experiments with intense neutron beams

Challenging neutron-capture cross-section measurements of small cross sections and samples with a very limited number of atoms require high-flux time-of-flight facilities. In turn, such facilities need innovative detection setups that are fast, have low sensitivity to neutrons, can quickly recover from the so-called $\gamma$-flash, and offer the highest possible detection sensitivity. In this paper, we present several steps toward such advanced systems. Specifically, we describe the performance of a high-sensitivity experimental setup at CERN n\_TOF EAR2. It consists of nine sTED detector modules in a compact cylindrical configuration, two conventional used large-volume C$_{6}$D$_{6}$ detectors, and one LaCl$_{3}$(Ce) detector. The performance of these detection systems is compared using $^{93}$Nb($n$,$\gamma$) data. We also developed a detailed \textsc{Geant4} Monte Carlo model of the experimental EAR2 setup, which allows for a better understanding of the detector features, including their efficiency determination. This Monte Carlo model has been used for further optimization, thus leading to a new conceptual design of a $\gamma$ detector array, STAR, based on a deuterated-stilbene crystal array. Finally, the suitability of deuterated-stilbene crystals for the future STAR array is investigaged experimentally utilizing a small stilbene-d12 prototype. The results suggest a similar or superior performance of STAR with respect to other setups based on liquid-scintillators, and allow for additional features such as neutron-gamma discrimination and a higher level of customization capability.

physics.ins-det

Measurement and analysis of the $^{246}$Cm and $^{248}$Cm neutron capture cross-sections at the EAR2 of the n TOF facility

The $^{246}$Cm(n,$\gamma$) and $^{248}$Cm(n,$\gamma$) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three C$_6$D$_6$ detectors. This measurement is part of a collective effort to improve the capture cross-section data for Minor Actinides (MAs), which are required to estimate the production and transmutation rates of these isotopes in light water reactors and innovative reactor systems. In particular, the neutron capture in $^{246}$Cm and $^{248}$Cm open the path for the formation of other Cm isotopes and heavier elements such as Bk and Cf and the knowledge of (n,$\gamma$) cross-sections of these Cm isotopes plays an important role in the transport, transmutation and storage of the spent nuclear fuel. The reactions $^{246}$Cm(n,$\gamma$) and $^{248}$Cm(n,$\gamma$) have been the two first capture measurements analyzed at n_TOF EAR2. Until this experiment and two recent measurements performed at J-PARC, there was only one set of data of the capture cross-sections of $^{246}$Cm and $^{248}$Cm, that was obtained in 1969 in an underground nuclear explosion experiment. In the measurement at n_TOF a total of 13 resonances of $^{246}$Cm between 4 and 400 eV and 5 of $^{248}$Cm between 7 and 100 eV have been identified and fitted. The radiative kernels obtained for $^{246}$Cm are compatible with JENDL-5, but some of them are not with JENDL-4, which has been adopted by JEFF-3.3 and ENDF/B-VIII.0. The radiative kernels obtained for the first three $^{248}$Cm resonances are compatible with JENDL-5, however, the other two are not compatible with any other evaluation and are 20% and 60% larger than JENDL-5.

nucl-ex

A Segmented Total Energy Detector (sTED) optimized for $(n,\gamma)$ cross-section measurements at n_TOF EAR2

The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron-induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of $4\times 10^7$ neutrons per nominal proton pulse, which is 50 times higher than the one of Experimental ARea 1 (EAR1) of $8\times10^5$ neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detectors response, by reducing the active volume per module and by using a photomultiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to $\gamma$-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at n_TOF EAR2.

physics.ins-det

Analysis of neutron time-of-flight spectra with a Bayesian unfolding methodology

We have developed an innovative methodology for obtaining the neutron energy distribution from a time-of-flight (TOF) measurement based on the iterative Bayesian unfolding method and accurate Monte Carlo simulations. This methodology has been validated through the analysis of a realistic virtual $\beta$-decay experiment, including the most relevant systematic effects in a real experiment. The proposed methodology allowed for obtaining accurate results over the energy range above the neutron detection threshold.

physics.data-an

Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments

One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n\_TOF facility, the detectors of choice are the C$_{6}$D$_{6}$ liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n\_TOF 20~m fligth path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from $^{197}$Au($n$,$\gamma$), including the saturated 4.9~eV resonance which is an important component of normalization for neutron cross section measurements.

physics.ins-det

Recent highlights and prospects on (n,$\gamma$) measurements at the CERN n_TOF facility

Neutron capture cross-section measurements are fundamental in the study of the slow neutron capture (s-) process of nucleosynthesis and for the development of innovative nuclear technologies. One of the best suited methods to measure radiative neutron capture (n,$\gamma$) cross sections over the full stellar range of interest for all the applications is the time-of-flight (TOF) technique. Overcoming the current experimental limitations for TOF measurements, in particular on low mass unstable samples, requires the combination of facilities with high instantaneous flux, such as the CERN n_TOF facility, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution presents a summary about the recent highlights in the field of (n,$\gamma$) measurements at n_TOF. The recent upgrades in the facility and in new detector concepts for (n,\g) measurements are described. Last, an overview is given on the existing limitations and prospects for TOF measurements involving unstable targets and the outlook for activation measurements at the brand new high-flux n_TOF-NEAR station.

nucl-ex

New detection systems for an enhanced sensitivity in key stellar (n,$\gamma$) measurements

Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture measurements via the time-of-flight (TOF) technique on key $s$-process nuclei are often challenging. Difficulties arise from the limited mass ($\sim$mg) available and the high sample-related background in the case of the unstable $s$-process branching points. Measurements on neutron magic nuclei, that act as $s$-process bottlenecks, are affected by low (n,$\gamma$) cross sections and a dominant neutron scattering background. Overcoming these experimental challenges requires the combination of facilities with high instantaneous flux, such as n\_TOF-EAR2, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution reviews some of the latest detector developments in detection systems for (n,$\gamma$) measurements at n\_TOF, such as i-TED, an innovative detection system which exploits the Compton imaging technique to reduce the dominant neutron scattering background and s-TED, a highly segmented total energy detector intended for high flux facilities. The discussion will be illustrated with results of the first measurement of key the $s$-process branching-point reaction $^{79}$Se(n,$\gamma$).

nucl-ex

New perspectives for neutron capture measurements in the upgraded CERN-n_TOF Facility

The n_TOF facility has just undergone in 2021 a major upgrade with the installation of its third generation spallation target that has been designed to optimize the performance of the two n_TOF time-of-flight lines. This contribution describes the key features and limitations for capture measurements in the two beam lines prior to the target upgrade and presents first results of (n,$\gamma$) measurements carried out as part of the commissioning of the upgraded facility. In particular, the energy resolution, a key factor for both increasing the signal-to-background ratio and obtaining accurate resonance parameters, has been clearly improved for the 20 m long vertical beam-line with the new target design while keeping the remarkably high resolution of the long beamline n_TOF-EAR1. The improvements in the n_TOF neutron beam-lines need to be accompanied by improvements in the instrumentation. A review is given on recent detector R&D projects aimed at tackling the existing challenges and further improving the capabilities of this facility.

nucl-ex

First measurement of the $^{94}$Nb($n$,$\gamma$) cross section at the CERN n\_TOF facility

One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along different stages of stellar evolution.In the particular case of the radioactive $^{94}$Nb, the $^{94}$Nb($n$,$\gamma$) cross-section could play a role in the determination of the $s$-process production of $^{94}$Mo in AGB stars, which presently cannot be reproduced by state-of-the-art stellar models. There are no previous $^{94}$Nb($n$,$\gamma$) experimental data for the resolved and unresolved resonance regions mainly due to the difficulties in producing high-quality samples and also due to limitations in conventional detection systems commonly used in time-of-flight experiments.Motivated by this situation, a first measurement of the $^{94}$Nb($n$,$\gamma$) reaction was carried out at CERN n\_TOF, thereby exploiting the high luminosity of the EAR2 area in combination with a new detection system of small-volume C6D6-detectors and a high quality $^{94}$Nb-sample. The latter was based on hyper-pure $^{93}$Nb material activated at the high-flux reactor of ILL-Grenoble. An innovative ring-configuration detection system in close geometry around the capture sample allowed us to significantly enhance the signal-to-background ratio. This set-up was supplemented with two conventional C$_{6}$D$_{6}$ detectors and a high-resolution LaCl$_{3}$(Ce)-detector, which will be employed for addressing reliably systematic effects and uncertainties.At the current status of the data analysis, 18 resonance in $^{94}$Nb+$n$ have been observed for the first time in the neutron energy range from thermal up to 10 keV.

nucl-ex