SearcharxivSearch

arXiv subjects

V. Bartsch

Publications and source records attributed to V. Bartsch.

11 recordsLinked to original sources

Characterization of Unlearnable Noise with Mid-Circuit-Measurement-Based Cycle Benchmarking

Noise characterization of multi-qubit entangling Clifford operations is a key practical bottleneck for quantum error mitigation and for the calibration, validation, and optimization of quantum error-correction protocols, especially in the presence of state preparation and measurement (SPAM) errors. Although cycle benchmarking can isolate some Pauli error components, it cannot resolve the problem of coupled error parameters, which leads to unlearnable degrees of freedom even in simple noisy gates, not to mention general $n$-qubit Clifford gates. Here we introduce mid-circuit-measurement-based generalized cycle benchmarking, a framework that makes otherwise unidentifiable Pauli fidelities and non-Markovian noise learnable via repeated measurements and classical post-processing. Applying the deferred feed-forward principle to generalized cycle benchmarking, we show that an insertion of mid-circuit measurements can reverse Pauli cycles induced by a general Clifford gate. This fact enables us to reveal a Pauli-noise learnability condition for Clifford gates. Assuming sufficient state preparation quality, we numerically demonstrate the feasibility of characterizing the previously unlearnable noise components. We implement the protocol on superconducting quantum processing units and validate its effectiveness in disambiguating the coupled noise components, benchmarked against conventional tomography. Finally, we observe consistent measurement-induced bit-flip bias and non-Markovian correlations, which define a range of applicability for the Pauli noise model and the proposed noise-characterization protocol.

quant-ph

Optimal Particle-Conserved Linear Encoding for Practical Fermionic Simulation

Number-conserved subspace encoding reduces resources needed for quantum simulations, but scalable complexity trade-off bounds for $M$ modes and $N$ particles with $\mathcal{O}(N\log M)$ qubits have remained unknown. We study qubit-gate-measurement trade-offs through the lens of classical/quantum error correction complexity, and develop a framework of fermionic gate and measurement complexity based on encoder and decoder complexities appeared in error correction framework. We demonstrate optimal encoding with random classical parity check code and propose the Fermionic Expectation Decoder for scalable probability decoding in $\mathcal{O}(M^4)$ bases. The protocol is tested with variational quantum eigensolver on LiH in the STO-3G and 6-31G basis, and $\text{H}_2$ potential energy curve in the 6-311G* basis.

quant-ph

Validation of GEANT4 Monte Carlo Models with a Highly Granular Scintillator-Steel Hadron Calorimeter

Calorimeters with a high granularity are a fundamental requirement of the Particle Flow paradigm. This paper focuses on the prototype of a hadron calorimeter with analog readout, consisting of thirty-eight scintillator layers alternating with steel absorber planes. The scintillator plates are finely segmented into tiles individually read out via Silicon Photomultipliers. The presented results are based on data collected with pion beams in the energy range from 8GeV to 100GeV. The fine segmentation of the sensitive layers and the high sampling frequency allow for an excellent reconstruction of the spatial development of hadronic showers. A comparison between data and Monte Carlo simulations is presented, concerning both the longitudinal and lateral development of hadronic showers and the global response of the calorimeter. The performance of several GEANT4 physics lists with respect to these observables is evaluated.

physics.ins-det

Track segments in hadronic showers in a highly granular scintillator-steel hadron calorimeter

We investigate the three dimensional substructure of hadronic showers in the CALICE scintillator-steel hadronic calorimeter. The high granularity of the detector is used to find track segments of minimum ionising particles within hadronic showers, providing sensitivity to the spatial structure and the details of secondary particle production in hadronic cascades. The multiplicity, length and angular distribution of identified track segments are compared to GEANT4 simulations with several different shower models. Track segments also provide the possibility for in-situ calibration of highly granular calorimeters.

physics.ins-det

Development of a modular and scalable data acquisition system for calorimeters at a linear collider

A data acquisition (DAQ) system has been developed which will read out and control calorimeters serving as prototype systems for a future detector at an electron-positron linear collider. This is a modular, flexible and scalable DAQ system in which the hardware and signals are standards-based, using FPGAs and serial links. The idea of a backplaneless system was also pursued with a commercial development board housed in a PC and a chain of concentrator cards between it and the detector forming the basis of the system. As well as describing the concept and performance of the system, its merits and disadvantages are discussed.

physics.ins-det

Electromagnetic response of a highly granular hadronic calorimeter

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the hadronic calorimeter, one option is a highly granular sampling calorimeter with steel as absorber and scintillator layers as active material. High granularity is obtained by segmenting the scintillator into small tiles individually read out via silicon photo-multipliers (SiPM). A prototype has been built, consisting of thirty-eight sensitive layers, segmented into about eight thousand channels. In 2007 the prototype was exposed to positrons and hadrons using the CERN SPS beam, covering a wide range of beam energies and incidence angles. The challenge of cell equalization and calibration of such a large number of channels is best validated using electromagnetic processes. The response of the prototype steel-scintillator calorimeter, including linearity and uniformity, to electrons is investigated and described.

physics.ins-det

Study of the interactions of pions in the CALICE silicon-tungsten calorimeter prototype

A prototype silicon-tungsten electromagnetic calorimeter for an ILC detector was tested in 2007 at the CERN SPS test beam. Data were collected with electron and hadron beams in the energy range 8 to 80 GeV. The analysis described here focuses on the interactions of pions in the calorimeter. One of the main objectives of the CALICE program is to validate the Monte Carlo tools available for the design of a full-sized detector. The interactions of pions in the Si-W calorimeter are therefore confronted with the predictions of various physical models implemented in the GEANT4 simulation framework.

physics.ins-det

Construction and Commissioning of the CALICE Analog Hadron Calorimeter Prototype

An analog hadron calorimeter (AHCAL) prototype of 5.3 nuclear interaction lengths thickness has been constructed by members of the CALICE Collaboration. The AHCAL prototype consists of a 38-layer sandwich structure of steel plates and highly-segmented scintillator tiles that are read out by wavelength-shifting fibers coupled to SiPMs. The signal is amplified and shaped with a custom-designed ASIC. A calibration/monitoring system based on LED light was developed to monitor the SiPM gain and to measure the full SiPM response curve in order to correct for non-linearity. Ultimately, the physics goals are the study of hadron shower shapes and testing the concept of particle flow. The technical goal consists of measuring the performance and reliability of 7608 SiPMs. The AHCAL was commissioned in test beams at DESY and CERN. The entire prototype was completed in 2007 and recorded hadron showers, electron showers and muons at different energies and incident angles in test beams at CERN and Fermilab.

physics.ins-det

Design and Electronics Commissioning of the Physics Prototype of a Si-W Electromagnetic Calorimeter for the International Linear Collider

The CALICE collaboration is studying the design of high performance electromagnetic and hadronic calorimeters for future International Linear Collider detectors. For the electromagnetic calorimeter, the current baseline choice is a high granularity sampling calorimeter with tungsten as absorber and silicon detectors as sensitive material. A ``physics prototype'' has been constructed, consisting of thirty sensitive layers. Each layer has an active area of 18x18 cm2 and a pad size of 1x1 cm2. The absorber thickness totals 24 radiation lengths. It has been exposed in 2006 and 2007 to electron and hadron beams at the DESY and CERN beam test facilities, using a wide range of beam energies and incidence angles. In this paper, the prototype and the data acquisition chain are described and a summary of the data taken in the 2006 beam tests is presented. The methods used to subtract the pedestals and calibrate the detector are detailed. The signal-over-noise ratio has been measured at 7.63 +/- 0.01. Some electronics features have been observed; these lead to coherent noise and crosstalk between pads, and also crosstalk between sensitive and passive areas. The performance achieved in terms of uniformity and stability is presented.

physics.ins-det

An algorithm for calculating the Lorentz angle in silicon detectors

Future experiments will use silicon sensors in the harsh radiation environment of the LHC (Large Hadron Collider) and high magnetic fields. The drift direction of the charge carriers is affected by the Lorentz force due to the high magnetic field. Also the resulting radiation damage changes the properties of the drift. In this paper measurements of the Lorentz angle of electrons and holes before and after irradiation are reviewed and compared with a simple algorithm to compute the Lorentz angle.

physics.ins-det

Lorentz angle measurements in irradiated silicon detectors between 77 K and 300 K

Future experiments are using silicon detectors in a high radiation environment and in high magnetic fields. The radiation tolerance of silicon improves by cooling it to temperatures below 180 K. At low temperatures the mobility increases, which leads to larger deflections of the charge carriers by the Lorentz force. A good knowledge of the Lorentz angle is needed for design and operation of silicon detectors. We present measurements of the Lorentz angle between 77 K and 300 K before and after irradiation with a primary beam of 21 MeV protons.

physics.ins-det