Performance of Multiplexed XY Resistive Micromegas detectors in a high intensity beam

We present the performance of multiplexed XY resistive Micromegas detectors tested in the CERN SPS 100 GeV/c electron beam at intensities up to 3.3 $\times$ 10$^5$ e$^- $/(s$\cdot$cm$^2$). So far, all studies with multiplexed Micromegas have only been reported for tests with radioactive sources and cosmic rays. The use of multiplexed modules in high intensity environments was not explored due to the effect of ambiguities in the reconstruction of the hit point caused by the multiplexing feature. At the beam intensities analysed in this work and with a multiplexing factor of 5, more than 50% level of ambiguity is introduced. Our results prove that by using the additional information of cluster size and integrated charge from the signal clusters induced on the XY strips, the ambiguities can be reduced to a level below 2%. The tested detectors are used in the CERN NA64 experiment for tracking the incoming particles bending in a magnetic field in order to reconstruct their momentum. The average hit detection efficiency of each module was found to be $\sim$ 96% at the highest beam intensities. By using four modules a tracking resolution of 1.1% was obtained with $\sim$ 85% combined tracking efficiency.

physics.ins-det↗

High purity 100 GeV electron identification with synchrotron radiation

In high energy experiments such as active beam dump searches for rare decays and missing energy events, the beam purity is a crucial parameter. In this paper we present a technique to reject heavy charged particle contamination in the 100 GeV electron beam of the H4 beam line at CERN SPS. The method is based on the detection with BGO scintillators of the synchrotron radiation emitted by the electrons passing through a bending dipole magnet. A 100 GeV $π^-$ beam is used to test the method in the NA64 experiment resulting in a suppression factor of $10^{-5}$ while the efficiency for electron detection is $\sim$95%. The spectra and the rejection factors are in very good agreement with the Monte Carlo simulation. The reported suppression factors are significantly better than previously achieved.

physics.ins-det↗

Search for invisible decays of sub-GeV dark photons in missing-energy events at the CERN SPS

We report on a direct search for sub-GeV dark photons (A') which might be produced in the reaction e^- Z \to e^- Z A' via kinetic mixing with photons by 100 GeV electrons incident on an active target in the NA64 experiment at the CERN SPS. The A's would decay invisibly into dark matter particles resulting in events with large missing energy. No evidence for such decays was found with 2.75\cdot 10^{9} electrons on target. We set new limits on the γ-A' mixing strength and exclude the invisible A' with a mass < 100 MeV as an explanation of the muon g_μ-2 anomaly.

hep-ex↗

On detection of narrow angle e+e- pairs from dark photon decays

A class of models of dark sectors consider new very weak interaction between the ordinary and dark matter transmitted by U'(1) gauge bosons A' (dark photons) mixing with our photons. If such A's exist, they could be searched for in a light-shining-through-a-wall experiment with a high energy electron beam from the CERN SPS. The proposed search scheme suggests detection of the e+e- pairs produced in the A' -> e+e- decay with a very small opening angle. Coordinate chambers based on the thin-wall drift tubes with a minimal material budget and a two-hit resolution for e+ and e- tracks separated by more than 0.5 mm are considered as an option for detecting such pairs.

physics.ins-det↗

Direct Timing Method for Longitudinal Coordinate Determination in Straws

The considering different technics of measuring the longitudinal coordinates by the drift tubes. It is shown that the determination of the longitudinal coordinate by the direct time method provides the best longitudinal resolution. The realization of this method enables the development of coordinate detectors based on the straw with two-dimensional readout, which can be fast enough and not very complex.

physics.ins-det↗

Operating mode of high pressure straws with high spatial resolution

The article presents results of studying the operating mode of thin-walled drift tubes (straws) at flushing it with a high-pressure gas mixture, which allowed obtaining extremely high spatial resolution for straw detectors. The results of studying the radiation ageing of straws operating in this mode are also described.

physics.ins-det↗

A direct time measurements technique for the two-dimensional precision coordinate detectors based on thin-walled drift tubes

This article presents the results of a study of the longitudinal spatial resolution of 2 m long straw tubes by means of the direct timing method (DTM). The feasibility of achieving a coordinate resolution (r.m.s.) better than 2 cm over full length of the straw is demonstrated. The spatial resolution insignificantly changes when measured by detecting gammas from a Fe-55 gamma ray source or minimum ionizing particles from a Ru-106 source. The use of the same type of FEE for data taking both for measuring the drift time of ionization electrons and propagation of a signal along the anode wire allows one to construct a two-dimensional detector for precision coordinate measurements.

physics.ins-det↗

Development of High Granulated Straw Chambers of Large Sizes

We have developed the baseline design for the straw drift tube tracking detectors for high rate environment application. The low-mass inner straw elements and the technology of the multianode straws assembly was devised and checked. The prototype chamber was constructed and studied the granularity of similar chambers can be reduced to one cm2. Submitted to Physics of Elementary Particles and Atomic Nuclei, Letters

physics.ins-det↗