Searcharxiv⌕ Search

arXiv subjects

V. Egorov

Publications and source records attributed to V. Egorov.

62 records · Page 4Linked to original sources

Measurement of the two neutrino double beta decay half-life of Zr-96 with the NEMO-3 detector

Using 9.4 g of Zr-96 and 1221 days of data from the NEMO-3 detector corresponding to 0.031 kg yr, the obtained 2vbb decay half-life measurement is [2.35 +/- 0.14(stat) +/- 0.16(syst)] x 10^19 yr. Different characteristics of the final state electrons have been studied, such as the energy sum, individual electron energy, and angular distribution. The 2v nuclear matrix element is extracted using the measured 2vbb half-life and is 0.049 +/- 0.002. Constraints on 0vbb decay have also been set.

nucl-ex↗

Astroparticle Physics with a Customized Low-Background Broad Energy Germanium Detector

The MAJORANA Collaboration is building the MAJORANA DEMONSTRATOR, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The MAJORANA DEMONSTRATOR will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in the 1-10 GeV/c^2 mass range. We have found that customized Broad Energy Germanium (BEGe) detectors produced by Canberra have several desirable features for a neutrinoless double-beta decay experiment, including low electronic noise, excellent pulse shape analysis capabilities, and simple fabrication. We have deployed a customized BEGe, the MAJORANA Low-Background BEGe at Kimballton (MALBEK), in a low-background cryostat and shield at the Kimballton Underground Research Facility in Virginia. This paper will focus on the detector characteristics and measurements that can be performed with such a radiation detector in a low-background environment.

nucl-ex↗

Measurement of double beta decay of 100Mo to excited states in the NEMO 3 experiment

The double beta decay of 100Mo to the 0^+_1 and 2^+_1 excited states of 100Ru is studied using the NEMO 3 data. After the analysis of 8024 h of data the half-life for the two-neutrino double beta decay of 100Mo to the excited 0^+_1 state is measured to be T^(2nu)_1/2 = [5.7^{+1.3}_{-0.9}(stat)+/-0.8(syst)]x 10^20 y. The signal-to-background ratio is equal to 3. Information about energy and angular distributions of emitted electrons is also obtained. No evidence for neutrinoless double beta decay to the excited 0^+_1 state has been found. The corresponding half-life limit is T^(0nu)_1/2(0^+ --> 0^+_1) > 8.9 x 10^22 y (at 90% C.L.). The search for the double beta decay to the 2^+_1 excited state has allowed the determination of limits on the half-life for the two neutrino mode T^(2nu)_1/2(0^+ --> 2^+_1) > 1.1 x 10^21 y (at 90% C.L.) and for the neutrinoless mode T^(0nu)_1/2(0^+ --> 2^+_1) > 1.6 x 10^23 y (at 90% C.L.).

hep-ex↗

A New 76Ge Double Beta Decay Experiment at LNGS

This Letter of Intent has been submitted to the Scientific Committee of the INFN Laboratori Nazionali del Gran Sasso (LNGS) in March 2004. It describes a novel facility at the LNGS to study the double beta decay of 76Ge using an (optionally active) cryogenic fluid shield. The setup will allow to scrutinize with high significance on a short time scale the current evidence for neutrinoless double beta decay of 76Ge using the existing 76Ge diodes from the previous Heidelberg-Moscow and IGEX experiments. An increase in the lifetime limit can be achieved by adding more enriched detectors, remaining thereby background-free up to a few 100 kg-years of exposure.

hep-ex↗

Discovery of a Planar Waveguide for an X-Ray Radiation

A simple model of X-Ray standing waves (XSW) formation in the slit of a planar waveguide of X-Ray radiation beam for the angle area restricted by the critical total reflection angle is developed. It is shown that the model is true for a case of the Bragg reflection. The conditions required for XSW to appear in the space between two polished parallel plane plates are formulated and a slit size interval conforming to these conditions is evaluated. A mechanism of a XSW intensity decrease in a planar waveguide is proposed. This mechanism explains a high efficiency of slitless collimator application for the transportation of narrow X-Ray beams. Some recommendations on the application of the planar X-Ray waveguide in X-Ray structural and spectral studies of surface are presented.

physics.ins-det↗

Preliminary Results from the 1999 Balloon Flight of the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)

LXeGRIT is a balloon-borne Compton telescope employing a large volume liquid xenon time projection chamber (LXeTPC) as the central gamma-ray detector. It is designed to image gamma rays in the energy range of 200 keV to 20 MeV, with an angular resolution of about 3 degrees (1 sigma) at 2 MeV, within a field-of-view (FOV) of about 1 sr. The detector's energy and three-dimensional spatial resolution as measured during pre-flight calibration experiments, are $ΔE_\mathrm{lxe}/E=8.8% : \sqrt{1\MeV /E}$ and < 1mm RMS, respectively. The detection efficiency for Compton events varies between 1.5% and 4% depending on energy and event selection. We describe the instrument as flown on May 7, 1999 and review its overall performance at balloon altitude. The launch occurred at 13:26:54 UT from Ft. Sumner, New Mexico and the flight was terminated about 9 hours later. The Crab was in the instrument FOV for a few hours. Analysis of these data is in progress.

astro-ph↗

Compton scattering sequence reconstruction algorithm for the liquid xenon gamma-ray imaging telescope (LXeGRIT)

The Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT) is a balloon born experiment sensitive to \g -rays in the energy band of 0.2-20 MeV. The main detector is a time projection chamber filled with high purity liquid xenon (LXeTPC), in which the three-dimensional location and energy deposit of individual \g -ray interactions are accurately measured in one homogeneous volume. To determine the \g -ray initial direction (Compton imaging), as well as to reject background, the correct sequence of interactions has to be determined. Here we report the development and optimization of an algorithm to reconstruct the Compton scattering sequence and show its performance on Monte Carlo events and LXeGRIT data.

astro-ph↗

Spectroscopy and Imaging Performance of the Liquid Xenon Gamma-Ray Imaging Telescope (LXeGRIT)

LXeGRIT is a balloon-borne Compton telescope based on a liquid xenon time projection chamber (LXeTPC) for imaging cosmic \g-rays in the energy band of 0.2-20 MeV. The detector, with 400 cm$^2$ area and 7 cm drift gap, is filled with high purity LXe. Both ionization and scintillation light signals are detected to measure the energy deposits and the three spatial coordinates of individual \g -ray interactions within the sensitive volume. The TPC has been characterized with repeated measurements of its spectral and Compton imaging response to \g -rays from radioactive sources such as \na, \cs, \yt and Am-Be. The detector shows a linear response to \g -rays in the energy range 511 keV -4.4 MeV, with an energy resolution (FWHM) of $ ΔE/E=8.8% \: \sqrt{1\MeV /E}$. Compton imaging of \yt \g -ray events with two detected interactions is consistent with an angular resolution of $\sim$ 3 degrees (RMS) at 1.8 MeV.

astro-ph↗