Searcharxiv⌕ Search

arXiv subjects

V. Fadeyev

Publications and source records attributed to V. Fadeyev.

45 records · Page 3Linked to original sources

The Cleo Rich Detector

We describe the design, construction and performance of a Ring Imaging Cherenkov Detector (RICH) constructed to identify charged particles in the CLEO experiment. Cherenkov radiation occurs in LiF crystals, both planar and ones with a novel ``sawtooth''-shaped exit surface. Photons in the wavelength interval 135--165 nm are detected using multi-wire chambers filled with a mixture of methane gas and triethylamine vapor. Excellent pion/kaon separation is demonstrated.

physics.ins-det↗

Spectroscopic Observations and Analysis of the Unusual Type Ia SN 1999ac

We present optical spectra of the peculiar Type Ia supernova (SN Ia) 1999ac. The data extend from -15 to +42 days with respect to B-band maximum and reveal an event that is unusual in several respects. Prior to B-band maximum, the spectra resemble those of SN 1999aa, a slowly declining event, but possess stronger SiII and CaII signatures (more characteristic of a spectroscopically normal SN). Spectra after B-band maximum appear more normal. The expansion velocities inferred from the Iron lines appear to be lower than average; whereas, the expansion velocity inferred from Calcium H and K are higher than average. The expansion velocities inferred from SiII are among the slowest ever observed, though SN 1999ac is not particularly dim. The analysis of the parameters v_10, R(SiII), dv(SiII)/dt, and d_m15 further underlines the unique characteristics of SN 1999ac. We find convincing evidence of CII 6580 in the day -15 spectrum with ejection velocity v > 16,000 km/s, but this signature disappears by day -9. This rapid evolution at early times highlights the importance of extremely early-time spectroscopy.

astro-ph↗

Restframe I-band Hubble diagram for type Ia supernovae up to redshift z ~0.5

We present a novel technique for fitting restframe I-band light curves on a data set of 42 Type Ia supernovae (SNe Ia). Using the result of the fit, we construct a Hubble diagram with 26 SNe from the subset at 0.01< z<0.1. Adding two SNe at z~0.5 yields results consistent with a flat Lambda-dominated``concordance universe'' ($Ω_M,Ω_Λ$)=(0.25,0.75). For one of these, SN 2000fr, new near infrared data are presented. The high redshift supernova NIR data are also used to test for systematic effects in the use of SNe Ia as distance estimators. A flat, Lambda=0, universe where the faintness of supernovae at z~0.5 is due to grey dust homogeneously distributed in the intergalactic medium is disfavoured based on the high-z Hubble diagram using this small data-set. However, the uncertainties are large and no firm conclusion may be drawn. We explore the possibility of setting limits on intergalactic dust based on B-I and B-V colour measurements, and conclude that about 20 well measured SNe are needed to give statistically significant results. We also show that the high redshift restframe I-band data points are better fit by light curve templates that show a prominent second peak, suggesting that they are not intrinsically underluminous.

astro-ph↗

Spectroscopic confirmation of high-redshift supernovae with the ESO VLT

We present VLT FORS1 and FORS2 spectra of 39 candidate high-redshift supernovae that were discovered as part of a cosmological study using Type Ia supernovae (SNe Ia) over a wide range of redshifts. From the spectra alone, 20 candidates are spectrally classified as SNe Ia with redshifts ranging from z=0.212 to z=1.181. Of the remaining 19 candidates, 1 might be a Type II supernova and 11 exhibit broad supernova-like spectral features and/or have supernova-like light curves. The candidates were discovered in 8 separate ground-based searches. In those searches in which SNe Ia at z ~ 0.5 were targeted, over 80% of the observed candidates were spectrally classified as SNe Ia. In those searches in which SNe Ia with z > 1 were targeted, 4 candidates with z > 1 were spectrally classified as SNe Ia and later followed with ground and space based observatories. We present the spectra of all candidates, including those that could not be spectrally classified as supernova.

astro-ph↗

The Cleo III Ring Imaging Cherenkov Detector

The CLEO detector has been upgraded to include a state of the art particle identification system, based on the Ring Imaging Cherenkov Detector (RICH) technology, in order to take data at the upgraded CESR electron positron collider. The expected performance is reviewed, as well as the preliminary results from an engineering run during the first few months of operation of the CLEO III detector.

hep-ex↗

Performance of the CLEO III LiF-TEA Ring Imaging Cherenkov Detector in a High Energy Muon Beam

The CLEO III Ring Imaging Cherenkov detector uses LiF radiators to generate Cherenkov photons which are then detected by proportional wire chambers using a mixture of CH$_4$ and TEA gases. The first two photon detector modules which were constructed, were taken to Fermilab and tested in a beam dump that provided high momentum muons. We report on results using both plane and "sawtooth" shaped radiators. Specifically, we discuss the number of photoelectrons observed per ring and the angular resolution. The particle separation ability is shown to be sufficient for the physics of CLEO III.

hep-ex↗

The CLEO-III RICH Detector and Beam Test Results

We are constructing a Ring Imaging Cherenkov detector (RICH) for the CLEO III upgrade for precision charged hadron identification. The RICH uses plane and sawtooth LiF crystals as radiators, MWPCs as photon detectors with TEA as the photo-sensitive material, and low-noise Viking readout electronics. Results of a beam test of the first two out of total 30 sectors are presented.

hep-ex↗

The CLEO-III Ring Imaging Cherenkov Detector

The CLEO-III Detector upgrade for charged particle identification is discussed. The RICH design uses solid LiF crystal radiators coupled with multi-wire chamber photon detectors, using TEA as the photosensor, and low-noise Viking readout electronics. Results from our beam test at Fermilab are presented.

hep-ex↗