SearcharxivSearch

arXiv subjects

V. Khotilovich

Publications and source records attributed to V. Khotilovich.

6 recordsLinked to original sources

Radiation Testing of Electronics for the CMS Endcap Muon System

The electronics used in the data readout and triggering system for the Compact Muon Solenoid (CMS) experiment at the Large Hadron Collider (LHC) particle accelerator at CERN are exposed to high radiation levels. This radiation can cause permanent damage to the electronic circuitry, as well as temporary effects such as data corruption induced by Single Event Upsets. Once the High Luminosity LHC (HL-LHC) accelerator upgrades are completed it will have five times higher instantaneous luminosity than LHC, allowing for detection of rare physics processes, new particles and interactions. Tests have been performed to determine the effects of radiation on the electronic components to be used for the Endcap Muon electronics project currently being designed for installation in the CMS experiment in 2013. During these tests the digital components on the test boards were operating with active data readout while being irradiated with 55 MeV protons. In reactor tests, components were exposed to 30 years equivalent levels of neutron radiation expected at the HL-LHC. The highest total ionizing dose (TID) for the muon system is expected at the inner-most portion of the CMS detector, with 8900 rad over ten years. Our results show that Commercial Off-The-Shelf (COTS) components selected for the new electronics will operate reliably in the CMS radiation environment.

physics.ins-det

The Timing System for the CDF Electromagnetic Calorimeters

We report on the design and performance of the electromagnetic calorimeter timing readout system (EMTiming) for the Collider Detector at Fermilab (CDF). The system will be used in searches for rare events with high energy photons to verify that the photon is in time with the event collision, to reject cosmic ray and beam halo backgrounds, and to allow direct searches for new heavy long-lived particles that decay to photons. The installation and commissioning of all 862 channels was completed in Fall 2004 as part of an upgrade to the Run II version of the detector. Using in-situ data, including electrons from W=>e nu and Z => ee decays, we measure the energy threshold for a time to be recorded to be 3.8 \pm 0.3GeV in the central portion of the detector and 1.9 \pm 0.1 GeV in the plug portion. Similarly, we measure a timing resolution of 600 \pm 10 ps and 610 \pm 10 ps for electrons above 10 GeV and 6 GeV respectively. There are very few system pathologies such as recording a time when no energy is deposited, or recording a second, fake time for a single energy deposit.

physics.ins-det

Minimal SUGRA Model and Collider Signals

The SUSY signals in the dominant stau-neutralino coannihilation region at a 500(800) GeV linear collider are investigated. The region is consistent with the WMAP measurement of the cold dark matter relic density as well as all other current experimental bounds within the mSUGRA framework. The signals are characterized by an existence of very low-energy tau leptons in the final state due to small mass difference between stau_1 and chi_1 (5-15 GeV). We study the accuracy of the mass difference measurement with a 1^deg active mask to reduce a huge SM two-photon background.

hep-ph

Selection of Tau Leptons with the CDF II Trigger System

In Run II of the CDF experiment, traditional dilepton triggers are enriched by lepton (electrons or muons) plus track, di-tau and tau plus missing transverse energy triggers at Level-3 dedicated to physical processes including tau leptons. We describe these triggers, along with their physics motivations, implementation and cross-sections and report on their initial performance.

hep-ex

mSUGRA At A 500-GeV Linear Collider

A study is made of what SUSY signals would be observable for mSUGRA models in a 500-GeV linear collider. All current experimental bounds on the mSUGRA parameter space are imposed. For m_0 < 1 TeV (or alternately if the current g_μ- 2 anomaly maintains) the only observable signals that remain are slepton pair production and neutralino production of {\tildeχ^0_2}+{\tildeχ^0_1}. Slepton pair production can occur for masses < 250 GeV which for the selectron and smuon pairs require tanbeta < 40. In this domain very accurate selectron and smuon masses could be measured. Light staus, \tildeτ_1, with mass < 250 GeV can be pair produced for any tanbeta and the neutralino signal can be seen provided m_{1/2}<~400 GeV. However, the detection of these requires a much more complicated analysis due to the fact that the dark matter co-annihilation constraint requires that the \tildeτ_1 and {\tildeχ^0_1} mass difference be <~ 15 GeV. The point m_{1/2} = 360 GeV, A_0 = 0, μ>0 is analyzed in detail, and it is shown that the stau and neutralino signals can be detected provided an active mask down to 2^o is used. However, large parts of the mSUGRA parameter space exists where a 500-GeV machine would not be able to see any SUSY signal.

hep-ph

Probing mSUGRA Models at Linear Colliders

A feasibility study of a 500-GeV linear collider is presented for mSUGRA models in co-annihilation region. We find an active mask is critical to suppress $e^+ e^- \to e^+ e^- τ^+ τ^-$ events to probe the models.

hep-ph