SearcharxivSearch

arXiv subjects

V. Kuryatkov

Publications and source records attributed to V. Kuryatkov.

3 recordsLinked to original sources

A method to observe field-region oxide charge and inter-electrode isolation from $CV$-characteristics of $n$-on-$p$ devices

$N$-on-$p$ silicon sensors will be utilized in the Compact Muon Solenoid (CMS) detector's tracker and High Granularity Calorimeter (HGCAL) in the High Luminosity upgrade of the Large Hadron Collider (HL-LHC). Among their several advantages in terms of radiation hardness over the traditional $p$-on-$n$ sensors in the extreme radiation environment of the HL-LHC are electron collection instead of holes and overlapping maxima of weighting and electric fields at the charge-collecting electrodes. The disadvantage of the multi-channel SiO$_2$-passivated $n$-on-$p$ sensors is the generation of an inversion layer under the Si/SiO$_2$-interface by a positive interface-oxide-charge ($N_\textrm{ox}$) that at high densities can compromise the position resolution by creating a conduction channel between the electrodes. This issue is typically addressed by including additional isolation implants ($p$-stop, $p$-spray) between $n^+$-electrodes. Focusing on the guard-ring regions of $n$-on-$p$ sensors where no isolation implants are applied between the electrodes, a capacitance-voltage ($CV$) characterization study of both 6-inch wafer test diodes and 8-inch HGCAL prototype and pre-series sensors showed a distinct threshold voltage ($V_\textrm{th,iso}$) in the $CV$-characteristics of a biased $n^+$-electrode when its enclosing guard-ring was left floating. When reproduced by simulations, the measured $V_\textrm{th,iso}$ was found to contain information on the field-region $N_\textrm{ox}$ and indicate the threshold where the two electrodes become electrically isolated by the influence of the reverse bias voltage. Together with previous studies on the inter-electrode isolation of irradiated $n$-on-$p$ sensors, the results indicate that position sensitive $n$-on-$p$ sensors without isolation implants may be feasible in future HEP experiments.

physics.ins-det

Modeling of Surface Damage at the Si/SiO$_2$-interface of Irradiated MOS-capacitors

Surface damage caused by ionizing radiation in SiO$_2$ passivated silicon particle detectors consists mainly of the accumulation of a positively charged layer along with trapped-oxide-charge and interface traps inside the oxide and close to the Si/SiO$_2$-interface. High density positive interface net charge can be detrimental to the operation of a multi-channel $n$-on-$p$ sensor since the inversion layer generated under the Si/SiO$_2$-interface can cause loss of position resolution by creating a conduction channel between the electrodes. In the investigation of the radiation-induced accumulation of oxide charge and interface traps, a capacitance-voltage characterization study of n/$γ$- and $γ$-irradiated Metal-Oxide-Semiconductor (MOS) capacitors showed that close agreement between measurement and simulation were possible when oxide charge density was complemented by both acceptor- and donor-type deep interface traps with densities comparable to the oxide charges. Corresponding inter-strip resistance simulations of a $n$-on-$p$ sensor with the tuned oxide charge density and interface traps show close agreement with experimental results. The beneficial impact of radiation-induced accumulation of deep interface traps on inter-electrode isolation may be considered in the optimization of the processing parameters of isolation implants on $n$-on-$p$ sensors for the extreme radiation environments.

physics.ins-det

Charge Collection and Electrical Characterization of Neutron Irradiated Silicon Pad Detectors for the CMS High Granularity Calorimeter

The replacement of the existing endcap calorimeter in the Compact Muon Solenoid (CMS) detector for the high-luminosity LHC (HL-LHC), scheduled for 2027, will be a high granularity calorimeter. It will provide detailed position, energy, and timing information on electromagnetic and hadronic showers in the immense pileup of the HL-LHC. The High Granularity Calorimeter (HGCAL) will use 120-, 200-, and 300-$μ\textrm{m}$ thick silicon (Si) pad sensors as the main active material and will sustain 1-MeV neutron equivalent fluences up to about $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$. In order to address the performance degradation of the Si detectors caused by the intense radiation environment, irradiation campaigns of test diode samples from 8-inch and 6-inch wafers were performed in two reactors. Characterization of the electrical and charge collection properties after irradiation involved both bulk polarities for the three sensor thicknesses. Since the Si sensors will be operated at -30 $^\circ$C to reduce increasing bulk leakage current with fluence, the charge collection investigation of 30 irradiated samples was carried out with the infrared-TCT setup at -30 $^\circ$C. TCAD simulation results at the lower fluences are in close agreement with the experimental results and provide predictions of sensor performance for the lower fluence regions not covered by the experimental study. All investigated sensors display 60$\%$ or higher charge collection efficiency at their respective highest lifetime fluences when operated at 800 V, and display above 90$\%$ at the lowest fluence, at 600 V. The collected charge close to the fluence of $10^{16}~\textrm{n}_\textrm{eq}\textrm{cm}^{-2}$ exceeds 1 fC at voltages beyond 800 V.

physics.ins-det