SearcharxivSearch

arXiv subjects

V. Lepeltier

Publications and source records attributed to V. Lepeltier.

7 recordsLinked to original sources

Single electron response and energy resolution of a Micromegas detector

Micro-Pattern Gaseous Detectors (MPGDs) such as Micromegas or GEM are used in particle physics experiments for their capabilities in particle tracking at high rates. Their excellent position resolutions are well known but their energy characteristics have been less studied. The energy resolution is mainly affected by the ionisation processes and detector gain fluctuations. This paper presents a method to separetely measure those two contributions to the energy resolution of a Micromegas detector. The method relies on the injection of a controlled number of electrons. The Micromegas has a 1.6-mm drift zone and a 160-$μ$m amplification gap. It is operated in Ne 95%-iC$\mathrm{_4}$H$\mathrm{_{10}}$ 5% at atmospheric pressure. The electrons are generated by non-linear photoelectric emission issued from the photons of a pulsed 337-nm wavelength laser coupled to a focusing system. The single electron response has been measured at different gains (3.7 10$\mathrm{^4}$, 5.0 10$\mathrm{^4}$ and 7.0 10$\mathrm{^4}$) and is fitted with a good agreement by a Polya distribution. From those fits, a relative gain variance of 0.31$\pm$0.02 is deduced. The setup has also been characterised at several voltages by fitting the energy resolution measured as a function of the number of primary electrons, ranging from 5 up to 210. A maximum value of the Fano factor (0.37) has been estimated for a 5.9 keV X-rays interacting in the Ne 95%-iC$\mathrm{_4}$H$\mathrm{_{10}}$ 5% gas mixture.

physics.ins-det

Micromegas TPC studies at high magnetic fields using the charge dispersion signal

The International Linear Collider (ILC) Time Projection Chamber (TPC) transverse space-point resolution goal is 100 microns for all tracks including stiff 90 degree tracks with the full 2 meter drift. A Micro Pattern Gas Detector (MPGD) readout TPC can achieve the target resolution with existing techniques using 1 mm or narrower pads at the expense of increased detector cost and complexity. The new MPGD readout technique of charge dispersion can achieve good resolution without resorting to narrow pads. This has been demonstrated previously for 2 mm x 6 mm pads with GEMs and Micromegas in cosmic ray tests and in a KEK beam test in a 1 Tesla magnet. We have recently tested a Micromegas-TPC using the charge dispersion readout concept in a high field super-conducting magnet at DESY. The measured Micromegas gain was found to be constant within 0.5% for magnetic fields up to 5 Tesla. With the strong suppression of transverse diffusion at high magnetic fields, we measure a flat 50 micron resolution at 5 Tesla over the full 15 cm drift length of our prototype TPC.

physics.ins-det

Spatial Resolution of a Micromegas-TPC Using the Charge Dispersion Signal

The Time Projection Chamber (TPC) for the International Linear Collider will need to measure about 200 track points with a resolution close to 100 $μ$m. A Micro Pattern Gas Detector (MPGD) readout TPC could achieve the desired resolution with existing techniques using sub-millimeter width pads at the expense of a large increase in the detector cost and complexity. We have recently applied a new MPGD readout concept of charge dispersion to a prototype GEM-TPC and demonstrated the feasibility of achieving good resolution with pads similar in width to the ones used for the proportional wire TPC. The charge dispersion studies were repeated with a Micromegas TPC amplification stage. We present here our first results on the Micromegas-TPC resolution with charge dispersion. The TPC resolution with the Micromegas readout is compared to our earlier GEM results and to the resolution expected from electron statistics and transverse diffusion in a gaseous TPC.

physics.ins-det

NOSTOS: a spherical TPC to detect low energy neutrinos

A novel low-energy ($\sim$few keV) neutrino-oscillation experiment NOSTOS, combining a strong tritium source and a high pressure spherical Time Projection Chamber (TPC) detector 10 m in radius has been recently proposed. The oscillation of neutrinos of such energies occurs within the size of the detector itself, potentially allowing for a very precise (and rather systematics-free) measure of the oscillation parameters, in particular, of the smaller mixing angle $θ_{13}$, which value could be determined for the first time. This detector could also be sensitive to the neutrino magnetic moment and be capable of accurately measure the Weinberg angle at low energy. The same apparatus, filled with high pressure Xenon, exhibits a high sensitivity as a Super Nova neutrino detector with extra galactic sensitivity. The outstanding benefits of the new concept of the spherical TPC will be presented, as well as the issues to be demonstrated in the near future by an ongoing R&D. The very first results of small prototype in operation in Saclay are shown.

hep-ex

NOSTOS experiment and new trends in rare event detection

A novel low-energy neutrino-oscillation experiment NOSTOS, combining a strong tritium source and a high pressure spherical TPC detector (10 m in radius) has been recently proposed. The goal of the experiment is to measure the mixing angle $θ_{13}$, the neutrino magnetic moment and the Weinberg angle at low energy. The same apparatus, filled with high pressure Xenon, exhibits a high sensitivity as a Super Nova neutrino detector with extra galactic sensitivity. Results of a first prototype will be shown and a short-term experimental program will be discussed.

hep-ex

First tests of a Micromegas TPC in a magnetic field

Since the summer of 2003, a large Micromegas TPC prototype (1000 channels, 50 cm drift, 50 cm diameter) has been operated in a 2T superconducting magnet at Saclay. A description of this apparatus and first results from cosmic ray tests are presented. Additional measurements using simpler detectors with a laser source, an X-ray gun and radio-active sources are discussed. Drift velocity and gain measurements, electron attachment and aging studies for a Micromegas TPC are presented. In particular, using simulations and measurements, it is shown that an $Argon-CF_4$ mixture is optimal for operation at a future Linear Collider.

physics.ins-det

Ion backflow in the Micromegas TPC for the future linear collider

We present ion backflow measurements in a Micromegas (MICRO-MEsh GASeous detector) TPC device developed for the next high energy electron-positron linear collider under study and a simple explanation for this backflow. A Micromegas micro-mesh has the intrinsic property to naturally stop a large fraction of the secondary positive ions created in the avalanche. It is shown that under some workable conditions on the pitch of the mesh and on the gas mixture, the ion feedback is equal to the field ratio (ratio of the drift electric field to the amplification field). Measurements with an intense X-ray source are in good agreement with calculations and simulations. The conclusion is that in the electric field conditions foreseen for the Micromegas TPC (drift and amplification fields respectively equal to 150-200 V/cm and 50-80 kV/cm) the expected ion backflow will be of the order of $2 - 3 x 10^-3$. In addition, measurements have been done in a 2T magnetic field: as expected the ion backflow is not altered by the magnetic field.

physics.ins-det