SearcharxivSearch

arXiv subjects

V. Murugesan

Publications and source records attributed to V. Murugesan.

11 recordsLinked to original sources

DESHIMA 2.0: A 200-400 GHz Ultra-wideband Integrated Superconducting Spectrometer

DESHIMA (Deep Spectroscopic HIgh-redshift MApper) is a broadband integrated superconducting spectrometer (ISS) for millimeter (mm) / sub-millimeter (sub-mm) wave astronomy based on Kinetic Inductance Detectors (KIDs). This paper describes characterization of DESHIMA 2.0 in laboratory settings. The instrument features NbTiN superconducting microstrip (MS) filters with low-loss a-SiC:H dielectric and an ultra-wideband leaky-wave antenna. A laboratory setup was designed, incorporating the cryostat housing cryogenic optics and ISS chip comprising 339 KIDs connected to MS filters tuned for (sub-)mm wave frequencies. Room-temperature mirrors on a hexapod stage allowed precise positioning and alignment of optical elements. The sky-position chopper was positioned on a motor-controlled stage for fine-tuned control over its position and alignment. Thanks to the multiplexing capability of KIDs, we could simultaneously measure multiple performance metrics across the entire frequency range. We showed that DESHIMA 2.0 achieved significant improvements in performance compared to its predecessor (DESHIMA 1.0): measured instantaneous frequency coverage was 200$-$400 GHz with a mean filter $Q_{filter}$ of $340 \pm 50$; instrument efficiency reached $\sim8$ \%, indicating 4 times wider band coverage and 4 times higher sensitivity. The yield rate for MS filters exceeded 98 \%. The estimated aperture efficiency from measured beam patterns agreed well with the designed value of approximately 70 \%. The telescope far-field beam patterns calculated from measured beam patterns also exhibited good agreement with design specifications. We also demonstrated validity of a new method of absolute frequency calibration using the data from beam pattern measurement.

astro-ph.IM

AMKID -- a large KID-based camera at the APEX telescope

The thermal emission at sub-millimeter wavelengths carries unique information in many astronomical applications ranging from disks and planet formation around young stars, to galaxy evolution studies at cosmological distances. Advancing on the mapping speed to detect this faint emission in ground-based astronomy has been a technical challenge for decades. The APEX Microwave Kinetic Inductance Detector (AMKID) camera was designed to accomplish this task. The instrument is a wide field-of-view camera based on kinetic inductance detectors. It is installed on the 12~meter APEX telescope in Chile at 5.100~meters above see level. The instrument operates dual color, covering simultaneously the 350~GHz and 850~GHz atmospheric windows. It has a large field-of-view of 15.3'x15.3', and an unprecedented number of pixels: 13.952~detectors in the high frequency band and 3.520~detectors in the low frequency band. Here we present a complete description of the instrument design and construction together with results of the successful low frequency array (LFA) commissioning campaign executed during the last year. The LFA performance is in good agreement with design parameters, with detector sensitivity of 2.2~mK$\sqrt{s}$ and diffraction limited beam sizes of 17.0''. On-sky measurements demonstrate a sensitivity of 70-90~mJy$\sqrt{s}$ per detector when operating under good atmospheric conditions (PWV below 1.0mm). With this performance the LFA regularly achieve a mapping sensitivity of 25~mJy when mapping a square degree in an hour. AMKID on APEX with its dual color observing capabilities, high sensitivity, large field-of-view and high angular resolution holds the promise to open a new range of science with the APEX telescope.

astro-ph.IM

Geometry dependence of TLS noise and loss in a-SiC:H parallel plate capacitors for superconducting microwave resonators

Parallel plate capacitors (PPC) significantly reduce the size of superconducting microwave resonators, reducing the pixel pitch for arrays of single photon energy-resolving kinetic inductance detectors (KIDs). The frequency noise of KIDs is typically limited by tunneling Two-Level Systems (TLS), which originate from lattice defects in the dielectric materials required for PPCs. How the frequency noise level depends on the PPC's dimensions has not been experimentally addressed. We measure the frequency noise of 56 resonators with a-SiC:H PPCs, which cover a factor 44 in PPC area and a factor 4 in dielectric thickness. To support the noise analysis, we measure the TLS-induced, power-dependent, intrinsic loss and temperature-dependent resonance frequency shift of the resonators. From the TLS models, we expect a geometry-independent microwave loss and resonance frequency shift, set by the TLS properties of the dielectric. However, we observe a thickness-dependent microwave loss and resonance frequency shift, explained by surface layers that limit the performance of PPC-based resonators. For a uniform dielectric, the frequency noise level should scale directly inversely with the PPC area and thickness. We observe that an increase in PPC size reduces the frequency noise, but the exact scaling is, in some cases, weaker than expected. Finally, we derive an engineering guideline for the design of KIDs based on PPC-based resonators.

physics.ins-det

Model and Measurements of an Optical Stack for Broadband Visible to Near-IR Absorption in TiN KIDs

Typical materials for optical Kinetic Inductance Detetectors (KIDs) are metals with a natural absorption of 30-50% in the visible and near-infrared. To reach high absorption efficiencies (90-100%) the KID must be embedded in an optical stack. We show an optical stack design for a 60 nm TiN film. The optical stack is modeled as sections of transmission lines, where the parameters for each section are related to the optical properties of each layer. We derive the complex permittivity of the TiN film from a spectral ellipsometry measurement. The designed optical stack is optimised for broadband absorption and consists of, from top (illumination side) to bottom: 85 nm SiOx, 60 nm TiN, 23 nm of SiOx, and a 100 nm thick Al mirror. We show the modeled absorption and reflection of this stack, which has >80% absorption from 400 nm to 1550 nm and near-unity absorption for 500 nm to 800 nm. We measure transmission and reflection of this stack with a commercial spectrophotometer. The results are in good agreement with the model.

physics.optics

Ultra-sensitive Super-THz Microwave Kinetic Inductance Detectors for future space telescopes

Future actively cooled space-borne observatories for the far-infrared, loosely defined as a 1--10 THz band, can potentially reach a sensitivity limited only by background radiation from the Universe. This will result in an increase in observing speed of many orders of magnitude. A spectroscopic instrument on such an observatory requires large arrays of detectors with a sensitivity expressed as a noise equivalent power NEP = 3 $\times 10^{-20}$ $W\surd{Hz}$. We present the design, fabrication, and characterisation of microwave kinetic inductance detectors (MKIDs) for this frequency range reaching the required sensitivity. The devices are based on thin-film NbTiN resonators which use lens-antenna coupling to a submicron-width aluminium transmission line at the shorted end of the resonator where the radiation is absorbed. We optimised the MKID geometry for a low NEP by using a small aluminium volume of $\approx$ 1$μm^3$ and fabricating the aluminium section on a very thin (100 nm) SiN membrane. Both methods of optimisation also reduce the effect of excess noise by increasing the responsivity of the device, which is further increased by reducing the parasitic geometrical inductance of the resonator. We measure the sensitivity of eight MKIDs with respect to the power absorbed in the detector using a thermal calibration source filtered in a narrow band around 1.55 THz. We obtain a NEP$_{exp}(P_{abs})\:=\:3.1\pm0.9\times10^{-20}\:W\surd{Hz}$ at a modulation frequency of 200 Hz averaged over all measured MKIDs. The NEP is limited by quasiparticle trapping. The measured sensitivity is sufficient for spectroscopic observations from future, actively cooled space-based observatories. Moreover, the presented device design and assembly can be adapted for frequencies up to $\approx$ 10 THz and can be readily implemented in kilopixel arrays.

astro-ph.IM

Hydrogenated Amorphous Silicon Carbide: A Low-loss Deposited Dielectric for Microwave to Submillimeter Wave Superconducting Circuits

Low-loss deposited dielectrics will benefit superconducting devices such as integrated superconducting spectrometers, superconducting qubits and kinetic inductance parametric amplifiers. Compared with planar structures, multi-layer structures such as microstrips are more compact and eliminate radiation loss at high frequencies. Multi-layer structures are most easily fabricated with deposited dielectrics, which typically exhibit higher dielectric loss than crystalline dielectrics. We measured the sub-kelvin and low-power microwave and mm-submm wave dielectric loss of hydrogenated amorphous silicon carbide (a-SiC:H), using a superconducting chip with NbTiN/a-SiC:H/NbTiN microstrip resonators. We deposited the a-SiC:H by plasma-enhanced chemical vapor deposition at a substrate temperature of 400°C. The a-SiC:H has a mm-submm loss tangent ranging from $0.80 \pm 0.01 \times 10^{-4}$ to $1.43 \pm 0.04 \times 10^{-4}$ in the range of 270 to 385 GHz. The microwave loss tangent is $3.2 \pm 0.2 \times 10^{-5}$. These are the lowest low-power sub-kelvin loss tangents that have been reported for microstrip resonators at mm-submm and microwave frequencies. We observe that the loss tangent increases with frequency. The a-SiC:H films are free of blisters and have low stress: $-$20 MPa compressive at 200 nm thickness to 60 MPa tensile at 1000 nm thickness.

cond-mat.mtrl-sci

Superconducting Microstrip Losses at Microwave and Sub-millimeter wavelengths

We present a lab-on-chip experiment to accurately measure losses of superconducting microstrip lines at microwave and sub-mm wavelengths. The microstrips are fabricated from NbTiN, which is deposited using reactive magnetron sputtering, and amorphous silicon which is deposited using plasma-enhanced chemical vapor deposition (PECVD). Sub-mm wave losses are measured using on-chip Fabry-P{é}rot resonators (FPR) operating around $350\ $GHz. Microwave losses are measured using shunted half-wave resonators with an identical geometry and fabricated on the same chip. We measure a loss tangent of the amorphous silicon at single-photon energies of $\tanδ=3.7\pm0.5\times10^{-5}$ at $6\ $GHz and $\tanδ= 2.1\pm 0.1\times10^{-4}$ at $350\ $GHz. These results represent very low losses for deposited dielectrics, but the sub-mm wave losses are significantly higher than the microwave losses, which cannot be understood using the standard two-level system loss model.

physics.ins-det

Suppression of radiation loss in high kinetic inductance superconducting co-planar waveguides

We present a novel lab-on-chip technique to measure the very low losses in superconducting transmission lines at (sub-) mm wavelengths. The chips consist of a 100 nm thick NbTiN Coplanar Waveguide (CPW) Fabry Perot (FP) resonator, coupled on one side to an antenna and on the other side to a Microwave Kinetic Inductance detector. Using a single frequency radiation source allows us to measure the frequency response of the FP around 350 GHz and deduce its losses. We show that the loss is dominated by radiation loss inside the CPW line that forms the FP and that it decreases with decreasing line width and increasing kinetic inductance as expected. The results can be quantitatively understood using SONNET simulations. The lowest loss is observed for a CPW with a total width of $6\ \mathrm{μm}$ and corresponds to a Q-factor of $\approx15,000$.

physics.ins-det

Mitigation of Cosmic Ray Effect on Microwave Kinetic Inductance Detector Arrays

For space observatories, the glitches caused by high energy phonons created by the interaction of cosmic ray particles with the detector substrate lead to dead time during observation. Mitigating the impact of cosmic rays is therefore an important requirement for detectors to be used in future space missions. In order to investigate possible solutions, we carry out a systematic study by testing four large arrays of Microwave Kinetic Inductance Detectors (MKIDs), each consisting of $\sim$960 pixels and fabricated on monolithic 55 mm $\times$ 55 mm $\times$ 0.35 mm Si substrates. We compare the response to cosmic ray interactions in our laboratory for different detector arrays: A standard array with only the MKID array as reference; an array with a low $T_c$ superconducting film as phonon absorber on the opposite side of the substrate; and arrays with MKIDs on membranes. The idea is that the low $T_c$ layer down-converts the phonon energy to values below the pair breaking threshold of the MKIDs, and the membranes isolate the sensitive part of the MKIDs from phonons created in the substrate. We find that the dead time can be reduced up to a factor of 40 when compared to the reference array. Simulations show that the dead time can be reduced to below 1 % for the tested detector arrays when operated in a spacecraft in an L2 or a similar far-Earth orbit. The technique described here is also applicable and important for large superconducting qubit arrays for future quantum computers.

astro-ph.IM

A kilo-pixel imaging system for future space based far-infrared observatories using microwave kinetic inductance detectors

Future astrophysics and cosmic microwave background space missions operating in the far-infrared to millimetre part of the spectrum will require very large arrays of ultra-sensitive detectors in combination with high multiplexing factors and efficient low-noise and low-power readout systems. We have developed a demonstrator system suitable for such applications. The system combines a 961 pixel imaging array based upon Microwave Kinetic Inductance Detectors (MKIDs) with a readout system capable of reading out all pixels simultaneously with only one readout cable pair and a single cryogenic amplifier. We evaluate, in a representative environment, the system performance in terms of sensitivity, dynamic range, optical efficiency, cosmic ray rejection, pixel-pixel crosstalk and overall yield at at an observation centre frequency of 850 GHz and 20% fractional bandwidth. The overall system has an excellent sensitivity, with an average detector sensitivity NEPdet=3x10^-19 W/rt(Hz) measured using a thermal calibration source. At a loading power per pixel of 50fW we demonstrate white, photon noise limited detector noise down to 300 mHz. The dynamic range would allow the detection of 1 Jy bright sources within the field of view without tuning the readout of the detectors. The expected dead time due to cosmic ray interactions, when operated in an L2 or a similar far-Earth orbit, is found to be <4%. Additionally, the achieved pixel yield is 83% and the crosstalk between the pixels is <-30dB. This demonstrates that MKID technology can provide multiplexing ratios on the order of a 1000 with state-of-the-art single pixel performance, and that the technology is now mature enough to be considered for future space based observatories and experiments.

astro-ph.IM

Calibration scheme for large Kinetic Inductance Detector Arrays based on Readout Frequency Response

Microwave kinetic inductance detector (MKID) provides a way to build large ground based sub-mm instruments such as NIKA and A-MKID. For such instruments, therefore, it is important to understand and characterize the response to ensure good linearity and calibration over wide dynamic range. We propose to use the MKID readout frequency response to determine the MKID responsivity to an input optical source power. A signal can be measured in a KID as a change in the phase of the readout signal with respect to the KID resonant circle. Fundamentally, this phase change is due to a shift in the KID resonance frequency, in turn due to a radiation induced change in the quasiparticle number in the superconducting resonator. We show that shift in resonant frequency can be determined from the phase shift by using KID phase versus frequency dependence using a previously measured resonant frequency. Working in this calculated resonant frequency, we gain near linearity and constant calibration to a constant optical signal applied in a wide range of operating points on the resonance and readout powers. This calibration method has three particular advantages: first, it is fast enough to be used to calibrate large arrays, with pixel counts in the thousand of pixels; second, it is based on data that are already necessary to determine KID positions; third, it can be done without applying any optical source in front of the array.

astro-ph.IM