Growth and characterization of a Li2Mg2(MoO4)3 scintillating bolometer

Lithium magnesium molybdate (Li$_2$Mg$_2$(MoO$_4$)$_3$) crystals were grown by the low-thermal-gradient Czochralski method. Luminescence properties of the material (emission spectra, thermally stimulated luminescence, dependence of intensity on temperature, phosphorescence) have been studied under X-Ray excitation in the temperature interval from 8 K to 400 K, while at the same being operated as a scintillating bolometer at 20 mK for the first time. We demonstrated that Li$_2$Mg$_2$(MoO$_4)_3$ crystals are a potentially promising detector material to search for neutrinoless double beta decay of $^{100}$Mo.

physics.ins-det↗

Study of Rare Nuclear Processes with CUORE

TeO2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0ν} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment looking for neutrinoless double beta decay, it is not the only study that CUORE will contribute to in the field of nuclear and particle physics. As already done over the years with many small-scale experiments, CUORE will investigate both rare decays (such as the two-neutrino double beta decay of 130-Te and the hypothesized electron capture in 123-Te), and rare processes (e.g., dark matter and axion interactions). This paper describes some of the achievements of past experiments that used TeO2 bolometers, and perspectives for CUORE.

nucl-ex↗

Low Energy Analysis Techniques for CUORE

CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searches requires improving the energy threshold to 10 keV. In this paper, we describe the analysis techniques developed for the low energy analysis of CUORE-like detectors, using the data acquired from November 2013 to March 2015 by CUORE-0, a single-tower prototype designed to validate the assembly procedure and new cleaning techniques of CUORE. We explain the energy threshold optimization, continuous monitoring of the trigger efficiency, data and event selection, and energy calibration at low energies in detail. We also present the low energy background spectrum of CUORE-0 below 60keV. Finally, we report the sensitivity of CUORE to WIMP annual modulation using the CUORE-0 energy threshold and background, as well as an estimate of the uncertainty on the nuclear quenching factor from nuclear recoils in CUORE-0.

physics.ins-det↗

Search for Neutrinoless $β^{+}\hspace{-0.2em}EC$ Decay of $^{120}$Te with CUORE-0

We have performed a search for neutrinoless $β^{+}\hspace{-0.2em}EC$ decay of $^{120}$Te using the final CUORE-0 data release. We describe a new analysis method for the simultaneous fit of signatures with different event topology, and of data subsets with different signal efficiency, obtaining a limit on the half-life of the decay of $T_{1/2}>1.6\cdot10^{21}$ yr at $90\%$ CI. Combining this with results from Cuoricino, a predecessor experiment, we obtain the strongest limit to date, corresponding to $T_{1/2}>2.7\cdot10^{21}$ yr at $90\%$ CI.

nucl-ex↗

Development of $^{100}$Mo-containing scintillating bolometers for a high-sensitivity neutrinoless double-beta decay search

This paper reports on the development of a technology involving $^{100}$Mo-enriched scintillating bolometers, compatible with the goals of CUPID, a proposed next-generation bolometric experiment to search for neutrinoless double-beta decay. Large mass ($\sim$1~kg), high optical quality, radiopure $^{100}$Mo-containing zinc and lithium molybdate crystals have been produced and used to develop high performance single detector modules based on 0.2--0.4~kg scintillating bolometers. In particular, the energy resolution of the lithium molybdate detectors near the $Q$-value of the double-beta transition of $^{100}$Mo (3034~keV) is 4--6~keV FWHM. The rejection of the $α$-induced dominant background above 2.6~MeV is better than 8$σ$. Less than 10~$μ$Bq/kg activity of $^{232}$Th ($^{228}$Th) and $^{226}$Ra in the crystals is ensured by boule recrystallization. The potential of $^{100}$Mo-enriched scintillating bolometers to perform high sensitivity double-beta decay searches has been demonstrated with only 10~kg$\times$d exposure: the two neutrino double-beta decay half-life of $^{100}$Mo has been measured with the up-to-date highest accuracy as $T_{1/2}$ = [6.90 $\pm$ 0.15(stat.) $\pm$ 0.37(syst.)] $\times$ 10$^{18}$~yr. Both crystallization and detector technologies favor lithium molybdate, which has been selected for the ongoing construction of the CUPID-0/Mo demonstrator, containing several kg of $^{100}$Mo.

physics.ins-det↗

The projected background for the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to search for neutrinoless double beta decay of 130Te with an array of 988 TeO2 bolometers operating at temperatures around 10 mK. The experiment is currently being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay half-life of 9$\times$10$^{25}$ years after 5\,years of data taking. The main issue to be addressed to accomplish this aim is the rate of background events in the region of interest, which must not be higher than 10$^{-2}$\,counts/keV/kg/y. We developed a detailed Monte Carlo simulation, based on results from a campaign of material screening, radioassays, and bolometric measurements, to evaluate the expected background. This was used over the years to guide the construction strategies of the experiment and we use it here to project a background model for CUORE. In this paper we report the results of our study and our expectations for the background rate in the energy region where the peak signature of neutrinoless double beta decay of 130Te is expected.

physics.ins-det↗

CUORE Sensitivity to $0νββ$ Decay

We report a study of the CUORE sensitivity to neutrinoless double beta ($0νββ$) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the $0νββ$ decay half-life ($T_{1/2}^{0ν}$) at $90\%$ credibility interval (CI) -- i.e. the interval containing the true value of $T_{1/2}^{0ν}$ with $90\%$ probability -- and the $3 σ$ discovery sensitivity. We consider various background levels and energy resolutions, and describe the influence of the data division in subsets with different background levels. If the background level and the energy resolution meet the expectation, CUORE will reach a $90\%$ CI exclusion sensitivity of $2\cdot10^{25}$ yr with $3$ months, and $9\cdot10^{25}$ yr with $5$ years of live time. Under the same conditions, the discovery sensitivity after $3$ months and $5$ years will be $7\cdot10^{24}$ yr and $4\cdot10^{25}$ yr, respectively.

physics.ins-det↗

Enriched TeO$_2$ bolometers with active particle discrimination: towards the CUPID experiment

We present the performances of two 92% enriched $^{130}$TeO$_2$ crystals operated as thermal bolometers in view of a next generation experiment to search for neutrinoless double beta decay of $^{130}$Te. The crystals, 435 g each, show an energy resolution, evaluated at the 2615 keV $γ$-line of $^{208}$Tl, of 6.5 and 4.3 keV FWHM. The only observable internal radioactive contamination arises from $^{238}$U (15 and 8 $μ$Bq/kg, respectively). The internal activity of the most problematic nuclei for neutrinoless double beta decay, $^{226}$Ra and $^{228}$Th, are both evaluated as $<$3.1 $μ$Bq/kg for one crystal and $<$2.3 $μ$Bq/kg for the second. Thanks to the readout of the weak Cherenkov light emitted by $β/γ$ particles by means of Neganov-Luke bolometric light detectors we were able to perform an event-by-event identification of $β/γ$ events with a 95% acceptance level, while establishing a rejection factor of 98.21% and 99.99% for $α$ particles.

physics.ins-det↗

First test of an enriched $^{116}$CdWO$_4$ scintillating bolometer for neutrinoless double-beta-decay searches

For the first time, a cadmium tungstate crystal scintillator enriched in $^{116}$Cd has been succesfully tested as a scintillating bolometer. The measurement was performed above ground at a temperature of 18 mK. The crystal mass was 34.5 g and the enrichment level ~82 %. Despite a substantial pile-up effect due to above-ground operation, the detector demonstrated a high energy resolution (2-7 keV FWHM in 0.2-2.6 MeV $γ$ energy range), a powerful particle identification capability and a high level of internal radiopurity. These results prove that cadmium tungstate is an extremely promising detector material for a next-generation neutrinoless double-beta decay bolometric experiment, like that proposed in the CUPID project (CUORE Upgrade with Particle IDentification).

physics.ins-det↗