Searcharxiv⌕ Search

arXiv subjects

V. Novosad

Publications and source records attributed to V. Novosad.

At least 37 records · Page 2Linked to original sources

Measurement of Dielectric Loss in Silicon Nitride at Centimeter and Millimeter Wavelengths

This work presents a suite of measurement techniques for characterizing the dielectric loss tangent across a wide frequency range from $\sim$1 GHz to 150 GHz using the same test chip. In the first method, we fit data from a microwave resonator at different temperatures to a model that captures the two-level system (TLS) response to extract and characterize both the real and imaginary components of the dielectric loss. The inverse of the internal quality factor is a second measure of the overall loss of the resonator, where TLS loss through the dielectric material is typically the dominant source. The third technique is a differential optical measurement at 150 GHz. The same antenna feeds two microstrip lines with different lengths that terminate in two microwave kinetic inductance detectors (MKIDs). The difference in the detector response is used to estimate the loss per unit length of the microstrip line. Our results suggest a larger loss for SiN$_x$ at 150 GHz of ${\mathrm{\tan δ\sim 4\times10^{-3}}}$ compared to ${\mathrm{2.0\times10^{-3}}}$ and ${\mathrm{\gtrsim 1\times10^{-3}}}$ measured at $\sim$1 GHz using the other two methods. {These measurement techniques can be applied to other dielectrics by adjusting the microstrip lengths to provide enough optical efficiency contrast and other mm/sub-mm frequency ranges by tuning the antenna and feedhorn accordingly.

astro-ph.IM↗

Electromagnetic Properties of Aluminum-based Bilayers for Kinetic Inductance Detectors

The complex conductivity of a superconducting thin film is related to the quasiparticle density, which depends on the physical temperature and can also be modified by external pair breaking with photons and phonons. This relationship forms the underlying operating principle of Kinetic Inductance Detectors (KIDs), where the detection threshold is governed by the superconducting energy gap. We investigate the electromagnetic properties of thin-film aluminum that is proximitized with either a normal metal layer of copper or a superconducting layer with a lower $T_C$, such as iridium, in order to extend the operating range of KIDs. Using the Usadel equations along with the Nam expressions for complex conductivity, we calculate the density of states and the complex conductivity of the resulting bilayers to understand the dependence of the pair breaking threshold, surface impedance, and intrinsic quality factor of superconducting bilayers on the relative film thicknesses. The calculations and analyses provide theoretical insights in designing aluminum-based bilayer kinetic inductance detectors for detection of microwave photons and athermal phonons at the frequencies well below the pair breaking threshold of a pure aluminum film.

astro-ph.IM↗

Simultaneous Millimeter-wave, Gamma-ray, and Optical Monitoring of the Blazar PKS 2326-502 During a Flaring State

Including millimeter-wave (mm-wave) data in multi-wavelength studies of the variability of active galactic nuclei (AGN) can provide insights into AGN physics that are not easily accessible at other wavelengths. We demonstrate in this work the potential of cosmic microwave background (CMB) telescopes to provide long-term, high-cadence mm-wave AGN monitoring over large fractions of sky. We report on a pilot study using data from the SPTpol instrument on the South Pole Telescope (SPT), which was designed to observe the CMB at arcminute and larger angular scales. Between 2013 and 2016, SPTpol was used primarily to observe a single 500 deg^2 field, covering the entire field several times per day with detectors sensitive to radiation in bands centered at 95 and 150 GHz. We use SPT 150 GHz observations to create AGN light curves, and we compare these mm-wave light curves to those at other wavelengths, in particular gamma-ray and optical. In this Letter, we focus on a single source, PKS 2326-502, which has extensive, day-timescale monitoring data in gamma-ray, optical, and now mm-wave between 2013 and 2016. We find PKS 2326-502 to be in a flaring state in the first two years of this monitoring, and we present a search for evidence of correlated variability between mm-wave, optical R band, and gamma-ray observations. This pilot study is paving the way for AGN monitoring with current and upcoming CMB experiments such as SPT-3G, Simons Observatory, and CMB-S4, including multi-wavelength studies with facilities such as VRO-LSST.

astro-ph.HE↗

Large area photon calorimeter with Ir-Pt bilayer transition-edge sensor for the CUPID experiment

CUPID is a next-generation neutrinoless double-beta decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In this work we showcase light detectors based on a novel Ir-Pt bilayer transition edge sensor. We have performed a systematic study to improve the thermal coupling between the photon absorber and the sensor, and thereby its responsivity. Our first devices meet CUPID's baseline noise requirement of <100~eV rms. Our detectors have risetimes of $\sim$180 $μ$s and measured timing jitter of <20 $μ$s for the expected signal-to-noise at the Q-value of the decay, which achieves the CUPID's criterion of rejecting two-neutrino double-beta decay pileup events. The current work will inform the fabrication of future devices, culminating in the final TES design and a scaleable readout scheme for CUPID.

physics.ins-det↗

Light Dark Matter Detection with Hydrogen-rich Crystals and Low-Tc TES Detectors

Direct detection of nuclear scatterings of sub-GeV Dark Matter (DM) particles favors low-Z nuclei. Hydrogen nucleus, which has a single proton, provides the best kinematic match to a light dark matter particle. The characteristic nuclear recoil energy is boosted by a factor of a few tens from those for larger nuclei used in traditional Weakly Interacting Massive Particle (WIMP) searches. Furthermore, hydrogen is optimal not only for spin-independent nuclear scatterings of sub-GeV DM, but also for spin-dependent nuclear scatterings, where large parameter space remains unconstrained. In this paper, we first introduce hydrogen-rich crystals, which include water ice, acetylene, anthracene, trans-stilbene, and naphthalene. These crystals emit two classes of signals under kinetic excitations. One class of the signals is infrared photons, which are from optically active fundamental vibrational modes of molecules and are at corresponding characteristic wavelengths. The other is acoustic phonons, and optical phonons that decay into acoustic phonons. We then discuss the technical status and future researches of low-Tc Transition-Edge Sensor (TES) detectors, which measure single infrared photons and a small flux of acoustic phonons with desirable sensitivities. With theoretical modeling to select the hydrogen-rich crystals for the optimized science reach, development of ultra-sensitive low-Tc TES detectors for readout, and experimentally characterizing transport properties of photons and phonons in the selected hydrogen-rich crystals, a direct detection experiment can be built for measuring the large unexplored parameter space of light DM particles.

physics.ins-det↗

Searching for axion-like time-dependent cosmic birefringence with data from SPT-3G

Ultralight axionlike particles (ALPs) are compelling dark matter candidates because of their potential to resolve small-scale discrepancies between $Λ$CDM predictions and cosmological observations. Axion-photon coupling induces a polarization rotation in linearly polarized photons traveling through an ALP field; thus, as the local ALP dark matter field oscillates in time, distant static polarized sources will appear to oscillate with a frequency proportional to the ALP mass. We use observations of the cosmic microwave background from SPT-3G, the current receiver on the South Pole Telescope, to set upper limits on the value of the axion-photon coupling constant $g_{ϕγ}$ over the approximate mass range $10^{-22} - 10^{-19}$ eV, corresponding to oscillation periods from 12 hours to 100 days. For periods between 1 and 100 days ($4.7 \times 10^{-22} \text{ eV} \leq m_ϕ\leq 4.7 \times 10^{-20} \text{ eV}$), where the limit is approximately constant, we set a median 95% C.L. upper limit on the amplitude of on-sky polarization rotation of 0.071 deg. Assuming that dark matter comprises a single ALP species with a local dark matter density of $0.3\text{ GeV/cm}^3$, this corresponds to $g_{ϕγ} < 1.18 \times 10^{-12}\text{ GeV}^{-1} \times \left( \frac{m_ϕ}{1.0 \times 10^{-21} \text{ eV}} \right)$. These new limits represent an improvement over the previous strongest limits set using the same effect by a factor of ~3.8.

astro-ph.CO↗

Scintillation yield from electronic and nuclear recoils in superfluid $^4$He

Superfluid $^4$He is a promising target material for direct detection of light ($<$ 1 GeV) dark matter. Possible signal channels available for readout in this medium include prompt photons, triplet excimers, and roton and phonon quasiparticles. The relative yield of these signals has implications for the sensitivity and discrimination power of a superfluid $^4$He dark matter detector. Using a 16~cm$^3$ volume of 1.75~K superfluid $^4$He read out by six immersed photomultiplier tubes, we measured the scintillation from electronic recoils ranging between 36.3 and 185 keV$_\mathrm{ee}$, yielding a mean signal size of $1.25^{+0.03}_{-0.03}$~phe/keV$_\mathrm{ee}$, and nuclear recoils from 53.2 to 1090 keV$_\mathrm{nr}$. We compare the results of our relative scintillation yield measurements to an existing semiempirical model based on helium-helium and electron-helium interaction cross sections. We also study the behavior of delayed scintillation components as a function of recoil type and energy, a further avenue for signal discrimination in superfluid $^4$He.

physics.ins-det↗

The Design and Integrated Performance of SPT-3G

SPT-3G is the third survey receiver operating on the South Pole Telescope dedicated to high-resolution observations of the cosmic microwave background (CMB). Sensitive measurements of the temperature and polarization anisotropies of the CMB provide a powerful dataset for constraining cosmology. Additionally, CMB surveys with arcminute-scale resolution are capable of detecting galaxy clusters, millimeter-wave bright galaxies, and a variety of transient phenomena. The SPT-3G instrument provides a significant improvement in mapping speed over its predecessors, SPT-SZ and SPTpol. The broadband optics design of the instrument achieves a 430 mm diameter image plane across observing bands of 95 GHz, 150 GHz, and 220 GHz, with 1.2 arcmin FWHM beam response at 150 GHz. In the receiver, this image plane is populated with 2690 dual-polarization, tri-chroic pixels (~16000 detectors) read out using a 68X digital frequency-domain multiplexing readout system. In 2018, SPT-3G began a multiyear survey of 1500 deg$^{2}$ of the southern sky. We summarize the unique optical, cryogenic, detector, and readout technologies employed in SPT-3G, and we report on the integrated performance of the instrument.

astro-ph.IM↗

Performance and characterization of the SPT-3G digital frequency-domain multiplexed readout system using an improved noise and crosstalk model

The third generation South Pole Telescope camera (SPT-3G) improves upon its predecessor (SPTpol) by an order of magnitude increase in detectors on the focal plane. The technology used to read out and control these detectors, digital frequency-domain multiplexing (DfMUX), is conceptually the same as used for SPTpol, but extended to accommodate more detectors. A nearly 5x expansion in the readout operating bandwidth has enabled the use of this large focal plane, and SPT-3G performance meets the forecasting targets relevant to its science objectives. However, the electrical dynamics of the higher-bandwidth readout differ from predictions based on models of the SPTpol system due to the higher frequencies used, and parasitic impedances associated with new cryogenic electronic architecture. To address this, we present an updated derivation for electrical crosstalk in higher-bandwidth DfMUX systems, and identify two previously uncharacterized contributions to readout noise, which become dominant at high bias frequency. The updated crosstalk and noise models successfully describe the measured crosstalk and readout noise performance of SPT-3G. These results also suggest specific changes to warm electronics component values, wire-harness properties, and SQUID parameters, to improve the readout system for future experiments using DfMUX, such as the LiteBIRD space telescope.

astro-ph.IM↗

Roadmap on Spin-Wave Computing

Magnonics is a field of science that addresses the physical properties of spin waves and utilizes them for data processing. Scalability down to atomic dimensions, operations in the GHz-to-THz frequency range, utilization of nonlinear and nonreciprocal phenomena, and compatibility with CMOS are just a few of many advantages offered by magnons. Although magnonics is still primarily positioned in the academic domain, the scientific and technological challenges of the field are being extensively investigated, and many proof-of-concept prototypes have already been realized in laboratories. This roadmap is a product of the collective work of many authors that covers versatile spin-wave computing approaches, conceptual building blocks, and underlying physical phenomena. In particular, the roadmap discusses the computation operations with Boolean digital data, unconventional approaches like neuromorphic computing, and the progress towards magnon-based quantum computing. The article is organized as a collection of sub-sections grouped into seven large thematic sections. Each sub-section is prepared by one or a group of authors and concludes with a brief description of the current challenges and the outlook of the further development of the research directions.

physics.app-ph↗

Detection of Galactic and Extragalactic Millimeter-Wavelength Transient Sources with SPT-3G

High-angular-resolution cosmic microwave background experiments provide a unique opportunity to conduct a survey of time-variable sources at millimeter wavelengths, a population which has primarily been understood through follow-up measurements of detections in other bands. Here we report the first results of an astronomical transient survey with the South Pole Telescope (SPT) using the SPT-3G camera to observe 1500 square degrees of the southern sky. The observations took place from March to November 2020 in three bands centered at 95, 150, and 220 GHz. This survey yielded the detection of fifteen transient events from sources not previously detected by the SPT. The majority are associated with variable stars of different types, expanding the number of such detected flares by more than a factor of two. The stellar flares are unpolarized and bright, in some cases exceeding 1 Jy, and have durations from a few minutes to several hours. Another population of detected events last for 2--3 weeks and appear to be extragalactic in origin. Though data availability at other wavelengths is limited, we find evidence for concurrent optical activity for two of the stellar flares. Future data from SPT-3G and forthcoming instruments will provide real-time detection of millimeter-wave transients on timescales of minutes to months.

astro-ph.HE↗

Constraints on $Λ$CDM Extensions from the SPT-3G 2018 $EE$ and $TE$ Power Spectra

We present constraints on extensions to the $Λ$CDM cosmological model from measurements of the $E$-mode polarization auto-power spectrum and the temperature-$E$-mode cross-power spectrum of the cosmic microwave background (CMB) made using 2018 SPT-3G data. The extensions considered vary the primordial helium abundance, the effective number of relativistic degrees of freedom, the sum of neutrino masses, the relativistic energy density and mass of a sterile neutrino, and the mean spatial curvature. We do not find clear evidence for any of these extensions, from either the SPT-3G 2018 dataset alone or in combination with baryon acoustic oscillation and \textit{Planck} data. None of these model extensions significantly relax the tension between Hubble-constant, $H_0$, constraints from the CMB and from distance-ladder measurements using Cepheids and supernovae. The addition of the SPT-3G 2018 data to \textit{Planck} reduces the square-root of the determinants of the parameter covariance matrices by factors of $1.3 - 2.0$ across these models, signaling a substantial reduction in the allowed parameter volume. We also explore CMB-based constraints on $H_0$ from combined SPT, \textit{Planck}, and ACT DR4 datasets. While individual experiments see some indications of different $H_0$ values between the $TT$, $TE$, and $EE$ spectra, the combined $H_0$ constraints are consistent between the three spectra. For the full combined datasets, we report $H_0 = 67.49 \pm 0.53\,\mathrm{km\,s^{-1}\,Mpc^{-1}}$, which is the tightest constraint on $H_0$ from CMB power spectra to date and in $4.1\,σ$ tension with the most precise distance-ladder-based measurement of $H_0$. The SPT-3G survey is planned to continue through at least 2023, with existing maps of combined 2019 and 2020 data already having $\sim3.5\times$ lower noise than the maps used in this analysis.

astro-ph.CO↗

Quantum engineering with hybrid magnonics systems and materials

Quantum technology has made tremendous strides over the past two decades with remarkable advances in materials engineering, circuit design and dynamic operation. In particular, the integration of different quantum modules has benefited from hybrid quantum systems, which provide an important pathway for harnessing the different natural advantages of complementary quantum systems and for engineering new functionalities. This review focuses on the current frontiers with respect to utilizing magnetic excitatons or magnons for novel quantum functionality. Magnons are the fundamental excitations of magnetically ordered solid-state materials and provide great tunability and flexibility for interacting with various quantum modules for integration in diverse quantum systems. The concomitant rich variety of physics and material selections enable exploration of novel quantum phenomena in materials science and engineering. In addition, the relative ease of generating strong coupling and forming hybrid dynamic systems with other excitations makes hybrid magnonics a unique platform for quantum engineering. We start our discussion with circuit-based hybrid magnonic systems, which are coupled with microwave photons and acoustic phonons. Subsequently, we are focusing on the recent progress of magnon-magnon coupling within confined magnetic systems. Next we highlight new opportunities for understanding the interactions between magnons and nitrogen-vacancy centers for quantum sensing and implementing quantum interconnects. Lastly, we focus on the spin excitations and magnon spectra of novel quantum materials investigated with advanced optical characterization.

cond-mat.mes-hall↗

A Demonstration of Improved Constraints on Primordial Gravitational Waves with Delensing

We present a constraint on the tensor-to-scalar ratio, $r$, derived from measurements of cosmic microwave background (CMB) polarization $B$-modes with "delensing," whereby the uncertainty on $r$ contributed by the sample variance of the gravitational lensing $B$-modes is reduced by cross-correlating against a lensing $B$-mode template. This template is constructed by combining an estimate of the polarized CMB with a tracer of the projected large-scale structure. The large-scale-structure tracer used is a map of the cosmic infrared background derived from Planck satellite data, while the polarized CMB map comes from a combination of South Pole Telescope, BICEP/Keck, and Planck data. We expand the BICEP/Keck likelihood analysis framework to accept a lensing template and apply it to the BICEP/Keck data set collected through 2014 using the same parametric foreground modelling as in the previous analysis. From simulations, we find that the uncertainty on $r$ is reduced by $\sim10\%$, from $σ(r)$= 0.024 to 0.022, which can be compared with a $\sim26\%$ reduction obtained when using a perfect lensing template. Applying the technique to the real data, the constraint on $r$ is improved from $r_{0.05} < 0.090$ to $r_{0.05} < 0.082$ (95\% C.L.). This is the first demonstration of improvement in an $r$ constraint through delensing.

astro-ph.CO↗

Measurements of the E-Mode Polarization and Temperature-E-Mode Correlation of the CMB from SPT-3G 2018 Data

We present measurements of the $E$-mode ($EE$) polarization power spectrum and temperature-$E$-mode ($TE$) cross-power spectrum of the cosmic microwave background using data collected by SPT-3G, the latest instrument installed on the South Pole Telescope. This analysis uses observations of a 1500 deg$^2$ region at 95, 150, and 220 GHz taken over a four month period in 2018. We report binned values of the $EE$ and $TE$ power spectra over the angular multipole range $300 \le \ell < 3000$, using the multifrequency data to construct six semi-independent estimates of each power spectrum and their minimum-variance combination. These measurements improve upon the previous results of SPTpol across the multipole ranges $300 \le \ell \le 1400$ for $EE$ and $300 \le \ell \le 1700$ for $TE$, resulting in constraints on cosmological parameters comparable to those from other current leading ground-based experiments. We find that the SPT-3G dataset is well-fit by a $Λ$CDM cosmological model with parameter constraints consistent with those from Planck and SPTpol data. From SPT-3G data alone, we find $H_0 = 68.8 \pm 1.5 \mathrm{km\,s^{-1}\,Mpc^{-1}}$ and $σ_8 = 0.789 \pm 0.016$, with a gravitational lensing amplitude consistent with the $Λ$CDM prediction ($A_L = 0.98 \pm 0.12$). We combine the SPT-3G and the Planck datasets and obtain joint constraints on the $Λ$CDM model. The volume of the 68% confidence region in six-dimensional $Λ$CDM parameter space is reduced by a factor of 1.5 compared to Planck-only constraints, with only slight shifts in central values. We note that the results presented here are obtained from data collected during just half of a typical observing season with only part of the focal plane operable, and that the active detector count has since nearly doubled for observations made with SPT-3G after 2018.

astro-ph.CO↗

Optimal CMB Lensing Reconstruction and Parameter Estimation with SPTpol Data

We perform the first simultaneous Bayesian parameter inference and optimal reconstruction of the gravitational lensing of the cosmic microwave background (CMB), using 100 deg$^2$ of polarization observations from the SPTpol receiver on the South Pole Telescope. These data reach noise levels as low as 5.8 $μ$K-arcmin in polarization, which are low enough that the typically used quadratic estimator (QE) technique for analyzing CMB lensing is significantly sub-optimal. Conversely, the Bayesian procedure extracts all lensing information from the data and is optimal at any noise level. We infer the amplitude of the gravitational lensing potential to be $A_ϕ\,{=}\,0.949\,{\pm}\,0.122$ using the Bayesian pipeline, consistent with our QE pipeline result, but with 17\% smaller error bars. The Bayesian analysis also provides a simple way to account for systematic uncertainties, performing a similar job as frequentist "bias hardening," and reducing the systematic uncertainty on $A_ϕ$ due to polarization calibration from almost half of the statistical error to effectively zero. Finally, we jointly constrain $A_ϕ$ along with $A_{\rm L}$, the amplitude of lensing-like effects on the CMB power spectra, demonstrating that the Bayesian method can be used to easily infer parameters both from an optimal lensing reconstruction and from the delensed CMB, while exactly accounting for the correlation between the two. These results demonstrate the feasibility of the Bayesian approach on real data, and pave the way for future analysis of deep CMB polarization measurements with SPT-3G, Simons Observatory, and CMB-S4, where improvements relative to the QE can reach 1.5 times tighter constraints on $A_ϕ$ and 7 times lower effective lensing reconstruction noise.

astro-ph.CO↗

Searching for Anisotropic Cosmic Birefringence with Polarization Data from SPTpol

We present a search for anisotropic cosmic birefringence in 500 deg$^2$ of southern sky observed at 150 GHz with the SPTpol camera on the South Pole Telescope. We reconstruct a map of cosmic polarization rotation anisotropies using higher-order correlations between the observed cosmic microwave background (CMB) $E$ and $B$ fields. We then measure the angular power spectrum of this map, which is found to be consistent with zero. The non-detection is translated into an upper limit on the amplitude of the scale-invariant cosmic rotation power spectrum, $L(L+1)C_L^{αα}/2π< 0.10 \times 10^{-4}$ rad$^2$ (0.033 deg$^2$, 95% C.L.). This upper limit can be used to place constraints on the strength of primordial magnetic fields, $B_{1 \rm Mpc} < 17 {\rm nG} $ (95% C.L.), and on the coupling constant of the Chern-Simons electromagnetic term $g_{aγ} < 4.0 \times 10^{-2}/H_I $ (95% C.L.), where $H_I$ is the inflationary Hubble scale. For the first time, we also cross-correlate the CMB temperature fluctuations with the reconstructed rotation angle map, a signal expected to be non-vanishing in certain theoretical scenarios, and find no detectable signal. We perform a suite of systematics and consistency checks and find no evidence for contamination.

astro-ph.CO↗

Controlling $T_c$ of Iridium Films Using the Proximity Effect

A superconducting Transition-Edge Sensor (TES) with low-$T_c$ is essential in a high resolution calorimetric detection. With a motivation of developing sensitive calorimeters for applications in cryogenic neutrinoless double beta decay searches, we have been investigating methods to reduce the $T_c$ of an Ir film down to 20 mK. Utilizing the proximity effect between a superconductor and a normal metal, we found two room temperature fabrication recipes of making Ir-based low-$T_c$ films. In the first approach, an Ir film sandwiched between two Au films, a Au/Ir/Au trilayer, has a tunable $T_c$ in the range of 20-100 mK depending on the relative thicknesses. In the second approach, a paramagnetic Pt thin film is used to create Ir/Pt bilayer with a tunable $T_c$ in the same range. We present detailed study of fabrication and characterization of Ir-based low-$T_c$ films, and compare the experimental results to theoretical models. We show that Ir-based films with predictable and reproducible critical temperature can be consistently fabricated for use in large scale detector applications.

cond-mat.supr-con↗