SearcharxivSearch

arXiv subjects

V. S. Morozov

Publications and source records attributed to V. S. Morozov.

17 recordsLinked to original sources

On Possibilities of High Precision Fundamental Physics Experiments in Spin-Transparent Storage Rings of Low Energy Polarized Electron Beams

We present a new design of highly specialized small storage rings for low energy polarized electron beams. The new design is based on the transparent spin methodology that cancels the spin precession due to the magnetic dipole moment at any energy while allowing for spin precession induced by the fundamental physics of interest to accumulate. The buildup of the vertical component of beam polarization can be measured using standard Mott Polarimetry that is optimal at low electron energy. Systematic uncertainties are suppressed using counter-rotating bunched beams with various polarization orientations. These rings can be used to directly measure the permanent electric dipole moment of the electron, relevant to CP violation and matter-antimatter asymmetry in the universe, and to search for dark energy and ultra-light dark matter.

physics.acc-ph

Design concept for the second interaction region for Electron-Ion Collider

The possibility of two interaction regions (IRs) is a design requirement for the Electron Ion Collider (the EIC). There is also a significant interest from the nuclear physics community in a 2nd IR with measurements capabilities complementary to those of the first IR. While the 2nd IR will be in operation over the entire energy range of ~20GeV to ~140GeV center of mass (CM). The 2nd IR can also provide an acceptance coverage complementary to that of the first. We present a brief overview and the current progress of the 2nd IR design in terms of the parameters, magnet layout, and beam dynamics.

physics.acc-ph

Transparent Spin Method for Spin Control of Hadron Beams in Colliders

We present a concept for control of the ion polarization, called a transparent spin method. The spin transparency is achieved by designing such a synchrotron structure that the net spin rotation angle in one particle turn is zero. The polarization direction of any ions including deuterons can be efficiently controlled using weak quasi-static fields. These fields allow for dynamic adjustment of the polarization direction during an experiment. The main features of the Transparent Spin method are illustrated in a figure-8 collider. The results are relevant to the Electron-Ion Collider considered in the US, the ion-ion collider NICA constructed in Russia, and a polarized Electron-ion collider planned in China.

physics.acc-ph

Very Asymmetric Collider for Dark Matter Search below 1 GeV

Current searches for a dark photon in the mass range below 1 GeV require an electron-positron collider with a luminosity at the level of at least $10^{34}$ cm$^{-2}$s$^{-1}$. The challenge is that, at such low energies, the collider luminosity rapidly drops off due to increase in the beam sizes, strong mutual focusing of the colliding beams, and enhancement of collective effects. Using recent advances in accelerator technology such as the nano-beam scheme of SuperKEK-B, high-current Energy Recovery Linacs (ERL), and magnetized beams, we propose a new configuration of an electron-positron collider based on a positron storage ring and an electron ERL. It allows one to achieve a luminosity of $>10^{34}$ cm$^{-2}$s$^{-1}$ at the center of momentum energy of <1 GeV. We present general considerations and a specific example of such a facility using the parameters of the SuperKEK-B positron storage ring and Cornell ERL project.

physics.acc-ph

Study of Beam Synchronization at JLEIC

The ion collider ring of Jefferson Lab Electron-Ion Collider (JLEIC) accommodates a wide range of ion energies, from 20 to 100 GeV for protons or from 8 to 40 GeV per nucleon for lead ions. In this medium energy range, ions are not fully relativistic, which means values of their relativistic beta are slightly below 1, leading to an energy dependence of revolution time of the collider ring. On the other hand, electrons with energy 3 GeV and above are already ultra-relativistic such that their speeds are effectively equal to the speed of light. The difference in speeds of colliding electrons and ions in JLEIC, when translated into a path-length difference necessary to maintain the same timing between electron and ion bunches, is quite large. In this paper, we explore schemes for synchronizing the electron and ion bunches at a collision point as the ion energy is varied.

physics.acc-ph

Storage-ring Electron Cooler for Relativistic Ion Beams

Application of electron cooling at ion energies above a few GeV has been limited due to reduction of electron cooling efficiency with energy and difficulty in producing and accelerating a high-current high-quality electron beam. A high-current storage-ring electron cooler offers a solution to both of these problems by maintaining high cooling beam quality through naturally-occurring synchrotron radiation damping of the electron beam. However, the range of ion energies where storage-ring electron cooling can be used has been limited by low electron beam damping rates at low ion energies and high equilibrium electron energy spread at high ion energies. This paper reports a development of a storage ring based cooler consisting of two sections with significantly different energies: the cooling and damping sections. The electron energy and other parameters in the cooling section are adjusted for optimum cooling of a stored ion beam. The beam parameters in the damping section are adjusted for optimum damping of the electron beam. The necessary energy difference is provided by an energy recovering SRF structure. A prototype linear optics of such storage-ring cooler and initial tracking simulations are presented and some potential issues such as coherent synchrotron radiation and beam break up are discussed.

physics.acc-ph

Ion Polarization Scheme for MEIC

The choice of a figure 8 shape for the booster and collider rings of MEIC opens wide possibilities for preservation of the ion polarization during beam acceleration as well as for control of the polarization at the collider's interaction points. As in the case of accelerators with Siberian snakes, the spin tune is energy independent but is equal to zero instead of one half. The figure-8 topology eliminates the effect of arcs on the spin motion. There appears a unique opportunity to control the polarization of any particle species including deuterons, using longitudinal fields of small integrated strength (weak solenoids). Contrary to existing schemes, using weak solenoids in figure-8 colliders, one can control the polarization at the interaction points without essentially any effect on the beam's orbital characteristics. A universal scheme for control of the polarization using weak solenoids provides an elegant solution to the problem of ion acceleration completely eliminating resonant beam depolarization. It allows one to easily adjust the polarization in any direction at any orbital location, which becomes necessary when transferring the beam from one ring into another or when measuring the polarization by polarimeters. It also allows for an easy manipulation of the spin direction at an interaction point during an experiment. The latter feature allows one to set up a spin-flipping system with a spin reversal time of less than a second. By compensating the coherent part of the zero-integer spin resonance strength, which arises due to errors in alignment of the magnetic element of the lattice, one can reduce the field integrals of the control solenoids by a few orders of magnitude.

physics.acc-ph

MEIC Design Summary

This document summarizes the design of Jefferson Lab's electron-ion collider, MEIC, as of January 20, 2015, and describes the facility whose cost was estimated for the United States Department of Energy Nuclear Sciences Advisory Committee EIC cost review of January 26-28, 2015. In particular, each of the main technical systems within the collider is presented to the level of the best current information.

physics.acc-ph

Electron Ion Collider: The Next QCD Frontier - Understanding the glue that binds us all

This White Paper presents the science case of an Electron-Ion Collider (EIC), focused on the structure and interactions of gluon-dominated matter, with the intent to articulate it to the broader nuclear science community. It was commissioned by the managements of Brookhaven National Laboratory (BNL) and Thomas Jefferson National Accelerator Facility (JLab) with the objective of presenting a summary of scientific opportunities and goals of the EIC as a follow-up to the 2007 NSAC Long Range plan. This document is a culmination of a community-wide effort in nuclear science following a series of workshops on EIC physics and, in particular, the focused ten-week program on "Gluons and quark sea at high energies" at the Institute for Nuclear Theory in Fall 2010. It contains a brief description of a few golden physics measurements along with accelerator and detector concepts required to achieve them, and it benefited from inputs from the users' communities of BNL and JLab. This White Paper offers the promise to propel the QCD science program in the U.S., established with the CEBAF accelerator at JLab and the RHIC collider at BNL, to the next QCD frontier.

nucl-ex

Numerical Studies of Optimization and Aberration Correction Methods for the Preliminary Demonstration of the Parametric Ionization Cooling (PIC) Principle in the Twin Helix Muon Cooling Channel

Muon colliders have been proposed for the next generation of particle accelerators that study high-energy physics at the energy and intensity frontiers. In this paper we study a possible implementation of muon ionization cooling, Parametric-resonance Ionization Cooling (PIC), in the twin helix channel. The resonant cooling method of PIC offers the potential to reduce emittance beyond that achievable with ionization cooling with ordinary magnetic focusing. We examine optimization of a variety of parameters, study the nonlinear dynamics in the twin helix channel and consider possible methods of aberration correction.

physics.acc-ph

One 4-Twist Helix Snake to Maintain Polarization in 8-120 GeV Proton Rings

Solenoid Siberian snakes have successfully maintained polarization in particle rings below 1 GeV, but never in multi-GeV rings because the Lorentz contraction of a solenoid's integral B dl would require impractically long high-field solenoids. High energy rings, such as Brookhaven's 255 GeV Relativistic Heavy Ion Collider (RHIC), use only odd multiples of pairs of transverse B-field Siberian snakes directly opposite each other. When it became impractical to use a pair of Siberian Snakes in Fermilab's 120 GeV Main Injector, we searched for a new type of single Siberian snake, which should overcome all depolarizing resonances in the 8.9 - 120 GeV range. We found that one snake made of one 4-twist helix and 2 short dipoles could maintain the polarization. This snake design might also be used at other rings, such as Japan's 30 GeV J-PARC, the 12 - 24 GeV NICA proton-deuteron collider at JINR-Dubna, and perhaps RHIC's injector, the 25 GeV AGS.

physics.acc-ph

Symmetric achromatic low-beta collider interaction region design concept

We present a new symmetry-based concept for an achromatic low-beta collider interaction region design. A specially-designed symmetric Chromaticity Compensation Block (CCB) induces an angle spread in the passing beam such that it cancels the chromatic kick of the final focusing quadrupoles. Two such CCBs placed symmetrically around an interaction point allow simultaneous compensation of the 1st-order chromaticities and chromatic beam smear at the IP without inducing significant 2nd-order aberrations to the particle trajectory. We first develop an analytic description of this approach and explicitly formulate 2nd-order aberration compensation conditions at the interaction point. The concept is next applied to develop an interaction region design for the ion collider ring of an electron-ion collider. We numerically evaluate performance of the design in terms of momentum acceptance and dynamic aperture. The advantages of the new concept are illustrated by comparing it to the conventional distributed-sextupole chromaticity compensation scheme.

physics.acc-ph

Parametric-resonance Ionization Cooling of Muon Beams

Cooling of muon beams for the next-generation lepton collider is necessary to achieve its higher luminosity with fewer muons. In this paper we present an idea to combine ionization cooling with parametric resonances that is expected to lead to muon beams with much smaller transverse sizes. We describe a linear magnetic transport channel where a half integer resonance is induced such that the normal elliptical motion of particles in x-x' phase space becomes hyperbolic, with particles moving to smaller x and larger x' at the channel focal points. Thin absorbers placed at the focal points of the channel then cool the angular divergence of the beam by the usual ionization cooling mechanism where each absorber is followed by RF cavities. We present a theory of Parametric-resonance Ionization Cooling (PIC), starting with the basic principles in the context of a simple quadrupole-focused beam line. Then we discuss detuning caused by chromatic, spherical, and non-linear field aberrations and the techniques needed to reduce the detuning. We discuss the requirement that PIC be accompanied by emittance exchange in order to keep the momentum spread sufficiently small. Examples of PIC channel are presented, along with computer simulations aimed at practical implementation of the described theoretical concept.

physics.acc-ph

Higher Order Spin Resonances in a 2.1 GeV/c Polarized Proton Beam

Spin resonances can depolarize or spin-flip a polarized beam. We studied 1st and higher order spin resonances with stored 2.1 GeV/c vertically polarized protons. The 1st order vertical (νy) resonance caused almost full spin-flip, while some higher order νy resonances caused partial depolarization. The 1st order horizontal (νx) resonance caused almost full depolarization, while some higher order νx resonances again caused partial depolarization. Moreover, a 2nd order νx resonance is about as strong as some 3rd order νx resonances, while some 3rd order νy resonances are much stronger than a 2nd order νy resonance. One thought that νy spin resonances are far stronger than νx, and that lower order resonances are stronger than higher order; the data do not support this.

physics.acc-ph

Updated Report Acceleration of Polarized Protons to 120-150 GeV/c at Fermilab

The SPIN@FERMI collaboration has updated its 1991-95 Reports on the acceleration of polarized protons in Fermilab's Main Injector, which was commissioned by Fermilab. This Updated Report summarizes some updated Physics Goals for a 120-150 GeV/c polarized proton beam. It also contains an updated discussion of the Modifications and Hardware needed for a polarized beam in the Main Injector, along with an updated Schedule and Budget.

physics.acc-ph

Wide spin resonance with an rf-bunched proton beam

We recently used an rf solenoid to study the widths of rf spin resonances with both unbunched and bunched beams of 2.1 GeV_c polarized protons stored in the COSY synchrotron. A map, with unbunched beam at different fixed rf-solenoid frequencies, showed a very shallow possible depolarization dip at the resonance. Next we made frequency sweeps of 400Hz, centered at similar frequencies, which greatly enhanced the dip. But, with a bunched proton beam, both the fixed-frequency and frequency-sweep techniques produced similar maps, and both bunched maps showed full beam depolarization over a wide region. Moreover, both were more than twice as wide as the unbunched dip. This widening of the proton resonance due to bunching is exactly opposite to the recently observed narrowing of deuteron resonances due to bunching.

physics.acc-ph