SearcharxivSearch

arXiv subjects

V. Tozzini

Publications and source records attributed to V. Tozzini.

6 recordsLinked to original sources

Towards Low-Energy Electron High-Resolution Spectroscopy with Transition-Edge Sensors

We present a study of the energy resolution of transition-edge sensors (TESs) for the detection of electrons in the 100 eV kinetic energy range. The TES is a Ti-Au bilayer with an active area of $(60 \times 60)$ $\mu \text{m}^2$ and a critical temperature of $\sim$ 80 mK. The electron source is based on vertically-aligned multiwall carbon nanotubes located inside the cryostat, with electrons generated via field emission. For electrons in the (92 - 99) eV kinetic energy range, we obtain a Gaussian energy resolution for fully-absorbed electrons of (0.479 $\pm$ 0.041 $\pm$ 0.055) eV. When considering the full-width at half-maximum of the peak, the corresponding resolution is of (1.44 $\pm$ 0.17 $\pm$ 0.27) eV. The former represents an improvement of (46 - 60)% with respect to previous results, and is mainly attributed to the reduction in the TES active area. The latter is instead an improvement of over a factor of 20, and is mainly due to the reduction in the emitting area of the electron source, which significantly suppresses electron back-scattering in proximity of the TES. These results represent a major milestone toward high-precision spectroscopy on low-energy electrons, which is a key objective for the PTOLEMY experiment.

physics.ins-det

Ultra-high precision high voltage system for PTOLEMY

The PTOLEMY project is prototyping a novel electromagnetic filter for high-precision $\beta$ spectroscopy, with the ultimate and ambitious long-term goal of detecting the cosmic neutrino background through electron capture on tritium bound to graphene. Intermediate small-scale prototypes can achieve competitive sensitivity to the effective neutrino mass, even with reduced energy resolution. To reach an energy resolution better than \SI{500}{meV} at the tritium $\beta$-spectrum endpoint of \SI{18.6}{keV}, and accounting for all uncertainties in the filtering chain, the electrode voltage must be controlled at the level of a few parts per million and monitored in real time. In this work, we present the first results obtained in this effort, using a chain of commercial ultra-high-precision voltage references, read out by precision multimeters and a \emph{field mill} device. The currently available precision on high voltage is, in the conservative case, as low as \SI{0.2}{ppm} per \SI{1}{kV} single board and $\lesssim$ \SI{50}{mV} over the \SI{10}{kV} series, presently limited by field mill read-out noise. However, assuming uncorrelated Gaussian noise extrapolation, the real precision could in principle be as low as \SI{0.05}{ppm} over \SI{20}{kV}.

physics.ins-det

A Demonstration of Slowed Electron ${\bf E} \times {\bf B}$ Drift for PTOLEMY

To resolve the effective neutrino mass $m_\beta$ with an energy resolution of 50~meV, the PTOLEMY experiment has proposed a novel transverse electromagnetic filtering process. Substantially reducing the kinetic energy of tritium $\beta$-decay electrons by counteracting motion from ${\bf E}$ $\times$ ${\bf B}$ and $\nabla{\rm B}$ drift, the PTOLEMY filter requires an input of emitted electron kinematic information to generate a tailored, suitable electric field for each candidate. The collaboration proposes to extract these quantities by using antennae to observe the relativistic frequency shift of emitted cyclotron radiation as an electron transits by ${\bf E}$ $\times$ ${\bf B}$ drift through a uniform magnetic field region preceding the filter. Electrons must be contained within this region long enough such that an adequate integrated radiated power signal is received to accurately estimate these kinematics. This necessitates a controlled, slowed drift speed. This paper presents the experimental design to vary ${\bf E}$ $\times$ ${\bf B}$ drift speed of carbon-14 $\beta$-decay electrons using a custom electrode field cage situated between the pole faces of an electromagnet. Matching our results with high-fidelity simulation, we deduce a capacity to increase particle time of flight by a factor of 5 in the field cage's slow drift region. Limited only by the dimensions of our system, we assert drift speed can be arbitrarily slowed to meet the needs of PTOLEMY's future detector. Actualizing such a system is a crucial milestone in developing the detector, enabling future cyclotron radiation measurements, filter implementation, and source injection.

physics.ins-det

Heisenberg's uncertainty principle in the PTOLEMY project: a theory update

We discuss the consequences of the quantum uncertainty on the spectrum of the electron emitted by the $\beta$-processes of a tritium atom bound to a graphene sheet. We analyze quantitatively the issue recently raised in [Cheipesh et al., Phys. Rev. D 104, 116004 (2021)], and discuss the relevant time scales and the degrees of freedom that can contribute to the intrinsic spread in the electron energy. We perform careful calculations of the potential between tritium and graphene with different coverages and geometries. With this at hand, we propose possible avenues to mitigate the effect of the quantum uncertainty.

hep-ph

Increasing the active surface of titanium islands on graphene by nitrogen sputtering

Titanium-island formation on graphene as a function of defect density is investigated. When depositing titanium on pristine graphene, titanium atoms cluster and form islands with an average diameter of about 10nm and an average height of a few atomic layers. We show that if defects are introduced in the graphene by ion bombardment, the mobility of the deposited titanium atoms is reduced and the average diameter of the islands decreases to 5nm with monoatomic height. This results in an optimized coverage for hydrogen storage applications since the actual titanium surface available per unit graphene area is significantly increased.

physics.chem-ph

Spontaneous formation and stability of small GaP fullerenes

We report the spontaneous formation of a GaP fullerene cage in ab-initio Molecular Dynamics simulations starting from a bulk fragment. A systematic study of the geometric and electronic properties of neutral and ionized GaP clusters suggests the stability of hetero-fullerenes formed by a compound with zincblend bulk structure. We find that GaP fullerenes up to 28 atoms have high symmetry, closed electronic shells, large HOMO-LUMO energy gaps and do not dissociate when ionized. We compare our results for GaP with those obtained by other groups for the corresponding BN clusters.

physics.chem-ph