SearcharxivSearch

arXiv subjects

V. Wagner

Publications and source records attributed to V. Wagner.

At least 19 recordsLinked to original sources

Probing the Size of Neutron and Proton Single-Particle Orbitals from Nucleon Knockout Reactions

The size of neutron and proton single-particle orbitals of $^{52}$Ca, $^{53}$Ca, $^{54}$Ca, and $^{55}$Sc were investigated via nucleon knockout reactions at $\sim$ 230 MeV/nucleon. The determination method is based on the measured fragment momentum distributions in $(p,pn)$ and $(p,2p)$ reactions, which are shown to be sensitive to the spatial extension of the wave function of the knocked-out nucleon, interpreted within the distorted wave impulse approximation (DWIA) framework. A systematic sensitivity study is carried out for the $(p,pn)$ recoil-momentum distribution method and is presented in this work. The experimental momentum distributions are compared to state-of-the-art mean field and $ab$ $initio$ in-medium similarity renormalization group and self-consistent Green's function calculations in combination with DWIA reaction theory calculations. Based on this work, the 1$p$ neutron orbitals are consistently found $0.48-0.78$ fm larger than the $0f_{7/2}$ neutron orbitals in $^{52-54}$Ca, while the size evolution of the valence proton orbitals remains inconclusive due to the large associated statistical uncertainties.

nucl-ex

The dipole strength distribution of $^8$He and decay characteristics

The weak binding and spatially extended neutron densities characteristic of drip-line nuclei give rise to a distinctive low-energy dipole response. The drip-line nucleus $^8$He is the most neutron-rich bound nucleus with a mass-to-charge ratio of $A/Z=4$. We measure the dipole response of $^8$He, including for the first time the four-neutron decay channel. A total dipole strength of $\sum B(E1)(E^*<15$~MeV$)=0.95(16)~e^2$fm$^2$ and a dipole polarizability of $\alpha_D = 0.61(1)$~fm$^3$ are extracted from the differential Coulomb-excitation cross section and compared to state-of-the-art theoretical calculations employing coupled cluster and three-body approaches. We find that the dipole continuum is dominated, even at high excitation energies well above the $4n$ decay threshold, by two-neutron emission, pointing to a $^6$He$+2n$ structure of the excited dipole mode. No indication was found for a $4n$ final-state correlation, while pronounced $nn$ and $^6$He-$n$ final-state correlations are apparent.

nucl-ex

Direct observation of three-neutron emission from $^7$He$^*$ and the search for the trineutron

Three-neutron emission from $^7$He has been directly measured for the first time, following neutron knockout from a $^8$He beam at 156 MeV/nucleon. A resonance-like structure at $2.08(4)$ MeV above the $^4$He+$3n$ threshold [$E_x=2.68(4)$ MeV] with a width of $3.9(2)$ MeV was observed and deduced to arise predominately from the predicted $J^{\pi}=3/2^{-}_2$ level. The three-neutron invariant-mass spectrum was reconstructed and found to peak at around 1 MeV and could, through complete simulations incorporating neutron-neutron correlations, be very well described by the sequential decay of $^7$He$^*$ via the $2_1^+$ excited state of $^6$He. No evidence was found for any significant three-neutron correlations beyond those expected from well-established two-body interactions, including a trineutron resonance.

nucl-ex

Sub-keV Electron Recoil Calibration for Macroscopic Cryogenic Calorimeters using a Novel X-ray Fluorescence Source

Percent-level calibration of cryogenic macro-calorimeters with energy thresholds below 100~eV are crucial for light Dark Matter (DM) searches and reactor neutrino studies based on coherent elastic neutrino-nucleus scattering (CEvNS). This paper presents a novel calibration source based on X-ray fluorescence (XRF) of light elements. It uses a $^{55}$Fe source to irradiate a two-staged target arrangement, emitting characteristic emission lines from 677\,eV to 6.5\,keV. We demonstrate the potential of this new XRF source to calibrate a 0.75 gram CaWO$_4$ crystal of the NUCLEUS and CRAB experiments. Additionally, we introduce CryoLab, an advanced analysis tool for cryogenic detector data, featuring robust methods for data processing, calibration, and high-level analysis, implemented in MATLAB and HDF5. We also present a phenomenological model for energy resolution, which incorporates statistical contributions, systematic effects, and baseline noise, enabling a novel approach to evaluating athermal phonon collection efficiency in macro-calorimeters based on transition edge sensors (TES).

physics.ins-det

Decoupling Pulse Tube Vibrations from a Dry Dilution Refrigerator at milli-Kelvin Temperatures

With the rising adoption of dry dilution refrigerators across scientific and industrial domains, there has been a pressing demand for highly efficient vibration decoupling systems capable of operation at cryogenic temperatures in order to achieve the low vibration levels required for operation of sensitive equipment like cryogenic detectors or quantum devices. As part of the NUCLEUS experiment, a cryogenic spring pendulum has been engineered to effectively isolate pulse tube vibrations by establishing an autonomous frame of reference for the experimental volume, while sustaining temperatures below 10 mK. Attaining attenuation of up to two orders of magnitude within the region of interest of the NUCLEUS cryogenic detectors, we achieved displacement RMS values in the order of 1 nm in the axial direction and 100 pm radially, thereby reducing vibrations below typical environmental levels. Our successful detector operation across multiple cooldown cycles demonstrated negligible sensitivity to pulse tube induced vibrations, culminating in the achievement of an ultra-low $(6.22 \pm 0.07)$ eV baseline resolution on a gram-scale CaWO$_4$ cryogenic calorimeter during continuous pulse tube operation over the course of several weeks.

physics.ins-det

Spectroscopy of $^{52}$K

The first spectroscopy of $^{52}$K was investigated via in-beam $\gamma$-ray spectroscopy at the RIKEN Radioactive Isotope Beam Factory after one-proton and one-neutron knockout from $^{53}$Ca and $^{53}$K beams impinging on a 15-cm liquid hydrogen target at $\approx$ 230~MeV/nucleon. The energy level scheme of $^{52}$K was built using single $\gamma$ and $\gamma$-$\gamma$ coincidence spectra. The spins and parities of the excited states were established based on momentum distributions of the fragment after the knockout reaction and based on exclusive cross sections. The results were compared to state-of-the-art shell model calculations with the SDPF-Umod interaction and ab initio IMSRG calculations with chiral effective field theory nucleon-nucleon and three-nucleon forces.

nucl-ex

Spectroscopy of deeply bound orbitals in neutron-rich Ca isotopes

The calcium isotopes are an ideal system to investigate the evolution of shell structure and magic numbers. Although the properties of surface nucleons in calcium have been well studied, probing the structure of deeply bound nucleons remains a challenge. Here, we report on the first measurement of unbound states in $^{53}$Ca and $^{55}$Ca, populated from \ts{54,56}Ca($p,pn$) reactions at a beam energy of around 216 MeV/nucleon at the RIKEN Radioactive Isotopes Beam Factory. The resonance properties, partial cross sections, and momentum distributions of these unbound states were analyzed. Orbital angular momentum $l$ assignments were extracted from momentum distributions based on calculations using the distorted wave impulse approximation (DWIA) reaction model. The resonances at excitation energies of 5516(41)\,keV in $^{53}$Ca and 6000(250)\,keV in $^{55}$Ca indicate a significant $l$\, =\,3 component, providing the first experimental evidence for the $\nu 0f_{7/2}$ single-particle strength of unbound hole states in the neutron-rich Ca isotopes. The observed excitation energies and cross-sections point towards extremely localized and well separated strength distributions, with some fragmentation for the $\nu 0f_{7/2}$ orbital in $^{55}$Ca. These results are in good agreement with predictions from shell-model calculations using the effective GXPF1Bs interaction and \textit{ab initio} calculations and diverge markedly from the experimental distributions in the nickel isotones at $Z=28$.

nucl-ex

First observation of single photons in a CRESST detector and new dark matter exclusion limits

The main goal of the CRESST-III experiment is the direct detection of dark matter particles via their scattering off target nuclei in cryogenic detectors. In this work we present the results of a Silicon-On-Sapphire (SOS) detector with a mass of 0.6$\,$g and an energy threshold of (6.7$\, \pm \,$0.2)$\,$eV with a baseline energy resolution of (1.0$\, \pm \,$0.2)$\,$eV. This allowed for a calibration via the detection of single luminescence photons in the eV-range, which could be observed in CRESST for the first time. We present new exclusion limits on the spin-independent and spin-dependent dark matter-nucleon cross section that extend to dark matter particle masses of less than 100$\,$MeV/c$^{2}$.

astro-ph.CO

DoubleTES detectors to investigate the CRESST low energy background: results from above-ground prototypes

In recent times, the sensitivity of low-mass direct dark matter searches has been limited by unknown low energy backgrounds close to the energy threshold of the experiments known as the low energy excess (LEE). The CRESST experiment utilises advanced cryogenic detectors constructed with different types of crystals equipped with Transition Edge Sensors (TESs) to measure signals of nuclear recoils induced by the scattering of dark matter particles in the detector. In CRESST, this low energy background manifests itself as a steeply rising population of events below 200 eV. A novel detector design named doubleTES using two identical TESs on the target crystal was studied to investigate the hypothesis that the events are sensor-related. We present the first results from two such modules, demonstrating their ability to differentiate between events originating from the crystal's bulk and those occurring in the sensor or in its close proximity.

physics.ins-det

A likelihood framework for cryogenic scintillating calorimeters used in the CRESST dark matter search

Cryogenic scintillating calorimeters are ultrasensitive particle detectors for rare event searches, particularly for the search for dark matter and the measurement of neutrino properties. These detectors are made from scintillating target crystals generating two signals for each particle interaction. The phonon (heat) signal precisely measures the deposited energy independent of the type of interacting particle. The scintillation light signal yields particle discrimination on an event-by-event basis. This paper presents a likelihood framework modeling backgrounds and a potential dark matter signal in the two-dimensional plane spanned by phonon and scintillation light energies. We apply the framework to data from CaWO$_4$-based detectors operated in the CRESST dark matter search. For the first time, a single likelihood framework is used in CRESST to model the data and extract results on dark matter in one step by using a profile likelihood ratio test. Our framework simultaneously fits (neutron) calibration data and physics (background) data and allows combining data from multiple detectors. Although tailored to CaWO$_4$-targets and the CRESST experiment, the framework can easily be expanded to other materials and experiments using scintillating cryogenic calorimeters for dark matter search and neutrino physics.

astro-ph.CO

Optimal operation of cryogenic calorimeters through deep reinforcement learning

Cryogenic phonon detectors with transition-edge sensors achieve the best sensitivity to light dark matter-nucleus scattering in current direct detection dark matter searches. In such devices, the temperature of the thermometer and the bias current in its readout circuit need careful optimization to achieve optimal detector performance. This task is not trivial and is typically done manually by an expert. In our work, we automated the procedure with reinforcement learning in two settings. First, we trained on a simulation of the response of three CRESST detectors used as a virtual reinforcement learning environment. Second, we trained live on the same detectors operated in the CRESST underground setup. In both cases, we were able to optimize a standard detector as fast and with comparable results as human experts. Our method enables the tuning of large-scale cryogenic detector setups with minimal manual interventions.

physics.ins-det

A Plastic Scintillation Muon Veto for Sub-Kelvin Temperatures

Rare-event search experiments located on-surface, such as short-baseline reactor neutrino experiments, are often limited by muon-induced background events. Highly efficient muon vetos are essential to reduce the detector background and to reach the sensitivity goals. We demonstrate the feasibility of deploying organic plastic scintillators at sub-Kelvin temperatures. For the NUCLEUS experiment, we developed a cryogenic muon veto equipped with wavelength shifting fibers and a silicon photo multiplier operating inside a dilution refrigerator. The achievable compactness of cryostat-internal integration is a key factor in keeping the muon rate to a minimum while maximizing coverage. The thermal and light output properties of a plastic scintillation detector were examined. We report first data on the thermal conductivity and heat capacity of the polystyrene-based scintillator UPS-923A over a wide range of temperatures extending below one Kelvin. The light output was measured down to 0.8K and observed to increase by a factor of 1.61$\pm$0.05 compared to 300K. The development of an organic plastic scintillation muon veto operating in sub-Kelvin temperature environments opens new perspectives for rare-event searches with cryogenic detectors at sites lacking substantial overburden.

physics.ins-det

Level Structures of $^{56,58}$Ca Cast Doubt on a doubly magic $^{60}$Ca

Gamma decays were observed in $^{56}$Ca and $^{58}$Ca following quasi-free one-proton knockout reactions from $^{57,59}$Sc beams at $\approx 200$ MeV/nucleon. For $^{56}$Ca, a $γ$ ray transition was measured to be 1456(12) keV, while for $^{58}$Ca an indication for a transition was observed at 1115(34) keV. Both transitions were tentatively assigned as the $2^+_1 \rightarrow 0^+_{gs}$ decays, and were compared to results from ab initio and conventional shell-model approaches. A shell-model calculation in a wide model space with a marginally modified effective nucleon-nucleon interaction depicts excellent agreement with experiment for $2^+_1$ level energies, two-neutron separation energies, and reaction cross sections, corroborating the formation of a new nuclear shell above the $N$ = 34 shell. Its constituents, the $0f_{5/2}$ and $0g_{9/2}$ orbitals, are almost degenerate. This degeneracy precludes the possibility for a doubly magic $^{60}$Ca and potentially drives the dripline of Ca isotopes to $^{70}$Ca or even beyond.

nucl-ex

Observation of a nuclear recoil peak at the 100 eV scale induced by neutron capture

Coherent elastic neutrino-nucleus scattering and low-mass Dark Matter detectors rely crucially on the understanding of their response to nuclear recoils. We report the first observation of a nuclear recoil peak at around 112 eV induced by neutron capture. The measurement was performed with a CaWO$_4$ cryogenic detector from the NUCLEUS experiment exposed to a $^{252}$Cf source placed in a compact moderator. The measured spectrum is found in agreement with simulations and the expected peak structure from the single-$γ$ de-excitation of $^{183}$W is identified with 3 $σ$ significance. This result demonstrates a new method for precise, in-situ, and non-intrusive calibration of low-threshold experiments.

nucl-ex

Study of collision and $γ$-cascade times following neutron-capture processes in cryogenic detectors

The emission of $γ$-rays after a neutron capture in a cryogenic detector can generate mono-energetic nuclear recoils in the sub-keV regime, of direct interest for the calibration of Dark Matter and Coherent Elastic Neutrino Nucleus Scattering experiments. Here we show that accurate predictions of the nuclear recoil spectra induced by neutron captures require taking into account the interplay between the development in time of the de-excitation $γ$-cascade of the target nucleus and that of the associated atomic collisions in matter. We present detailed simulations coupling the FIFRELIN code for the description of the $γ$-cascades and the IRADINA code for the modelling of the fast atomic movements in matter. Nuclear recoil spectra are predicted, and made available to the community, for concrete cases of Al$_2$O$_3$, Si, Ge and CaWO$_4$ crystals exposed to a low intensity beam of thermal neutrons. We find that timing effects cause new calibration peaks to emerge in the recoil spectra and also impact the shape of the continuous recoil distribution. We discuss how they could give access to a rich physics program, spanning the accurate study of the response of cryogenic detectors in the sub-keV range, tests of solid state physics simulations and tests of nuclear models.

physics.ins-det

Investigation of the $\mathbf{Σ^{0}}$ Production Mechanism in p(3.5 GeV)+p Collisions

The production of $Σ^0$ hyperons in proton proton collisions at a beam kinetic energy of 3.5 GeV impinging on a liquid hydrogen target was investigated using data collected with the HADES setup. The total production cross section is found to be $\mathrm{σ(pK^{+}Σ^{0}) [μb] = 17.7 \pm 1.7 (stat) \pm 1.6 (syst)}$. Differential cross section distributions of the exclusive channel $\mathrm{pp \rightarrow pK^{+}Σ^{0}}$ were analyzed in the center-of-mass, Gottfried-Jackson and helicity reference frames for the first time at the excess energy of 556 MeV. The data support the interplay between pion and kaon exchange mechanisms and clearly demonstrate the contribution of interfering nucleon resonances decaying to $\mathrm{K^{+}Σ^{0}}$. The Bonn-Gatchina partial wave analysis was employed to analyse the data. Due to the limited statistics, it was not possible to obtain an unambiguous determination of the relative contribution of intermediate nucleon resonances to the final state. However nucleon resonances with masses around 1.710 $\mathrm{GeV/c^{2}}$ ($\mathrm{N^{*}(1710)}$) and 1.900 $\mathrm{GeV/c^{2}}$ ($\mathrm{N^{*}(1900)}$ or $\mathrm{Δ^{*}(1900)}$) are preferred by the fit.

nucl-ex

Production of hydrogen isotopes and charged pions in p (3.5 GeV) + Nb reactions

The double differential production cross sections, $d^2σ/dΩdE$, for hydrogen isotopes and charged pions in the reaction of p + Nb at 3.5 GeV proton beam energy have been measured by the High Acceptance DiElectron Spectrometer (HADES). Thanks to the high acceptance of HADES at forward emission angles and usage of its magnetic field, the measured energy range of hydrogen isotopes could be significantly extended in comparison to the relatively scarce experimental data available in the literature. The data provide information about the development of the intranuclear cascade in the proton-nucleus collisions. They can as well be utilized to study the rate of energy/momentum dissipation in the nuclear systems and the mechanism of elementary and composite particle production in excited nuclear matter at normal density. Data of this type are important also for technological and medical applications. Our results are compared to models developed to describe the processes relevant to nuclear spallation (INCL++) or oriented to probe either the elementary hadronic processes in nuclear matter or the behavior of compressed nuclear matter (GiBUU).

nucl-ex