SearcharxivSearch

arXiv subjects

V. Yefremenko

Publications and source records attributed to V. Yefremenko.

At least 19 recordsLinked to original sources

The SPT-3G+ receiver design

We present the thermo-mechanical design of the cryostat and camera optics for SPT-3G+, a new receiver being developed for the South Pole Telescope (SPT). The receiver consists of 14 detector arrays of 90/150 GHz dichroic polarization-sensitive pixels, totaling 24,080 transition-edge sensor detectors. Each detector array lies at the end of an optics tube, each approximately 240 mm in diameter and 772 mm in length, which are arranged in a hexagonal close-packed configuration to achieve a 4 degree diameter field of view. Each optics tube contains four anti-reflection coated lenses fabricated from different materials (alumina, silicon, and nylon) that are designed to also provide infrared filtering that reduces the radiative loading on the cryogenic stages. The optics and detectors are cooled by a combination of a pulse tube cooler for the 40 K and 4 K stages, and a dilution refrigerator for the 1 K and 100 mK stages. Thermal modeling predicts the heat load to be less than 26 W and 1 W for the 40 K and 4 K stages, respectively. The 1,550 kg cryostat has a 1.1 meter diameter at the vacuum window, which is located near the telescope Gregorian focus, and 1.75 meters in height and length. Fabrication of the cryostat will begin in 2026, with installation on the SPT scheduled for the 2028-29 austral summer, ahead of the 2029 winter observing season.

astro-ph.IM

SPT-3G+: A Cosmic Microwave Background Experiment for the South Pole Telescope

SPT-3G+ is the next survey receiver planned to be installed in early 2029 on the 10-meter South Pole Telescope (SPT). This new receiver will feature 6,020 polarization-sensitive dichroic pixels with transition-edge sensors observing in frequency bands centered at 90 GHz and 150 GHz. The 24,080 detectors in the SPT-3G+ receiver will be cooled to 100 mK by a dilution refrigerator and read out using microwave SQUID multiplexing. The optical design of the receiver enables a 4 degree diameter field of view, which is broken up into 14 individual optics tubes each containing cryogenic alumina, silicon, and nylon lenses. These technology choices will allow the SPT-3G+ receiver to improve on the mapping speed of the currently operating SPT-3G receiver by nearly an order of magnitude. Once deployed, the SPT-3G+ receiver will observe for 6-years an area overlapping with the BICEP survey to achieve a combined (90 GHz and 150 GHz) CMB map depth of 0.5 uK-arcmin. Data from these observations will be used to create unprecedentedly deep CMB lensing maps, discover new galaxy clusters, and detect astrophysical transients. The lensing map produced by SPT-3G+ will be used to remove or "delens" foreground B modes, where large-scale structure gravitationally lenses the CMB and converts E modes into B-mode polarization, with the goal of revealing inflationary B modes. Together with data from the BICEP Array as part of the South Pole Observatory, SPT-3G+ data will be used to constrain the tensor-to-scalar ratio $r$ with a goal of achieving a measurement of $\sigma(r) = 0.001$

astro-ph.CO

The South Pole Telescope AGN Monitoring Campaign: First Release of SPTpol Bright AGN Light Curves

The South Pole Telescope (SPT) collaboration has recently embarked upon a campaign to monitor the brightness of a sample of active galactic nuclei (AGN), both in real time and in archival SPT data. The original design of the SPT was optimized for observations of the cosmic microwave background (CMB) at arc-minute and larger angular scales, and it has been used for this purpose for nearly twenty years, using three generations of CMB cameras. Recently it has been recognized that data from CMB experiments have the potential to be used for AGN monitoring. In this paper, we present the first public release of data from a full sample of SPT-monitored AGN, comprising 158 AGN light curves and associated data from the SPTpol camera, which was operational from 2012-2016. These light curves were created using observations from the SPTpol 500 deg$^{2}$ survey, in which the instrument was used to scan a 500 deg$^2$ patch of the sky several times per day with detectors sensitive to radiation in bands centered at 90 and 150 GHz. We provide a comprehensive description of the observations, the data processing methods, and the resulting light curve catalog. As an example of analyses that these data enable, we searched for a correlation between variability and spectral index, and we looked for ``bluer-when-brighter'' trends in the sample. Our analysis finds $> 10 \sigma$ correlation between fractional intrinsic variance and mean spectral index in the sample, but no significant evidence for bluer-when-brighter trends. The datasets from this study can be accessed through the SPT Treasury Record of AGN With Historical Activity and Time-Series or STRAWHAT catalog. This initial data release includes SPTpol light curves at 90 and 150 GHz, focusing on total intensity. In later updates, SPTpol polarization data and new observations from the SPT-3G instrument at 90, 150, and 220 GHz will be included.

astro-ph.GA

Design and Performance of the SPT-SLIM Receiver Cryostat

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) is a millimeter-wavelength line-intensity mapping experiment, which was deployed on the South Pole Telescope (SPT) during the 2024-2025 Austral summer season. This pathfinder experiment serves to demonstrate the on-sky operation of multi-pixel on-chip spectrometer technology. We report on the cryogenic performance of the SPT-SLIM receiver for the first year of commissioning observations. The SPT-SLIM receiver utilizes an Adiabatic Demagnetization Refrigerator (ADR) for cooling the focal plane of superconducting filterbank spectrometers to a temperature of 150 mK. We demonstrate stable thermal performance of the focal plane module during observations consistent with thermal modeling, enabling a cryogenic operating efficiency above 80%. We also report on the receiver control system design utilizing the Observatory Control System (OCS) platform for automated cryogenic operation on the SPT.

astro-ph.IM

An On-Sky Atmospheric Calibration of SPT-SLIM

We present the methodology and results of the on-sky responsivity calibration of the South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM). SPT-SLIM is a pathfinder line intensity mapping experiment utilizing the on-chip spectrometer technology, and was first deployed during the 2024-2025 Austral Summer season on the South Pole Telescope. During the two-week on-sky operation of SPT-SLIM, we performed periodic measurements of the detector response as a function of the telescope elevation angle. Combining these data with atmospheric opacity measurements from an on-site atmospheric tipping radiometer, simulated South Pole atmospheric spectra, and measured detector spectral responses, we construct estimates for the responsivity of SPT-SLIM detectors to sky loading. We then use this model to calibrate observations of the moon taken by SPT-SLIM, cross-checking the result against the known brightness temperature of the Moon as a function of its phase.

astro-ph.IM

Spectral characterization and performance of SPT-SLIM on-chip filterbank spectrometers

The South Pole Telescope Shirokoff Line Intensity Mapper (SPT-SLIM) experiment is a pathfinder for demonstrating the use of on-chip spectrometers for millimeter (mm) Line Intensity Mapping (LIM). We present spectral bandpass measurements of the SPT-SLIM spectrometer channels made on site using a Fourier Transform Spectrometer during the first deployment of SPT-SLIM in the 2024-2025 Austral summer season. We note the effect of FTS systematics on measurements of on-chip filterbank spectrometer resolutions and demonstrate a technique for measuring the narrow band passes of the SPT-SLIM filterbanks that improves beyond the intrinsic resolution of a Fourier Transform Spectrometer.

astro-ph.IM

Measurements of the Temperature and E-mode Polarization of the Cosmic Microwave Background from the Full 500-square-degree SPTpol Dataset

Using the full four-year SPTpol 500 deg$^2$ dataset in both the 95 GHz and 150 GHz frequency bands, we present measurements of the temperature and $E$-mode polarization of the cosmic microwave background (CMB), as well as the $E$-mode polarization auto-power spectrum ($EE$) and temperature-$E$-mode cross-power spectrum ($TE$) in the angular multipole range $50<\ell<8000$. We find the SPTpol dataset to be self-consistent, passing several internal consistency tests based on maps, frequency bands, bandpowers, and cosmological parameters. The full SPTpol dataset is well-fit by the $\Lambda CDM$ model, for which we find $H_0=70.48\pm2.16$ km s$^{-1}$ Mpc$^{-1}$ and $\Omega_m=0.271\pm0.026$, when using only the SPTpol data and a Planck-based prior on the optical depth to reionization. The $\Lambda CDM$ parameter constraints are consistent across the 95 GHz-only, 150 GHz-only, $TE$-only, and $EE$-only data splits. Between the $\ell<1000$ and $\ell>1000$ data splits, the $\Lambda CDM$ parameter constraints are borderline consistent at the $\sim2\sigma$ level. This consistency improves when including a parameter $A_L$, the degree of lensing of the CMB inferred from the smearing of acoustic peaks. When marginalized over $A_L$, the $\Lambda CDM$ parameter constraints from SPTpol are consistent with those from Planck. The power spectra presented here are the most sensitive measurements of the lensed CMB damping tail to date for roughly $\ell > 1700$ in $TE$ and $\ell > 2000$ in $EE$.

astro-ph.CO

Testing the $\mathbf{\Lambda}$CDM Cosmological Model with Forthcoming Measurements of the Cosmic Microwave Background with SPT-3G

We forecast constraints on cosmological parameters enabled by three surveys conducted with SPT-3G, the third-generation camera on the South Pole Telescope. The surveys cover separate regions of 1500, 2650, and 6000 ${\rm deg}^{2}$ to different depths, in total observing 25% of the sky. These regions will be measured to white noise levels of roughly 2.5, 9, and 12 $\mu{\rm K-arcmin}$, respectively, in CMB temperature units at 150 GHz by the end of 2024. The survey also includes measurements at 95 and 220 GHz, which have noise levels a factor of ~1.2 and 3.5 times higher than 150 GHz, respectively, with each band having a polarization noise level ~$\sqrt{\text{2}}$ times higher than the temperature noise. We use a novel approach to obtain the covariance matrices for jointly and optimally estimated gravitational lensing potential bandpowers and unlensed CMB temperature and polarization bandpowers. We demonstrate the ability to test the $\Lambda{\rm CDM}$ model via the consistency of cosmological parameters constrained independently from SPT-3G and Planck data, and consider the improvement in constraints on $\Lambda{\rm CDM}$ extension parameters from a joint analysis of SPT-3G and Planck data. The $\Lambda{\rm CDM}$ cosmological parameters are typically constrained with uncertainties up to ~2 times smaller with SPT-3G data, compared to Planck, with the two data sets measuring significantly different angular scales and polarization levels, providing additional tests of the standard cosmological model.

astro-ph.CO

Flaring Stars in a Non-targeted mm-wave Survey with SPT-3G

We present a flare star catalog from four years of non-targeted millimeter-wave survey data from the South Pole Telescope (SPT). The data were taken with the SPT-3G camera and cover a 1500-square-degree region of the sky from $20^{h}40^{m}0^{s}$ to $3^{h}20^{m}0^{s}$ in right ascension and $-42^{\circ}$ to $-70^{\circ}$ in declination. This region was observed on a nearly daily cadence from 2019-2022 and chosen to avoid the plane of the galaxy. A short-duration transient search of this survey yields 111 flaring events from 66 stars, increasing the number of both flaring events and detected flare stars by an order of magnitude from the previous SPT-3G data release. We provide cross-matching to Gaia DR3, as well as matches to X-ray point sources found in the second ROSAT all-sky survey. We have detected flaring stars across the main sequence, from early-type A stars to M dwarfs, as well as a large population of evolved stars. These stars are mostly nearby, spanning 10 to 1000 parsecs in distance. Most of the flare spectral indices are constant or gently rising as a function of frequency at 95/150/220 GHz. The timescale of these events can range from minutes to hours, and the peak $\nu L_{\nu}$ luminosities range from $10^{27}$ to $10^{31}$ erg s$^{-1}$ in the SPT-3G frequency bands.

astro-ph.SR

Quasiparticle Generation-Recombination Noise in the Limit of Low Detector Volume

We have measured the quasiparticle generation-recombination (GR) noise in aluminium lumped element kinetic inductors with a wide range of detector volumes at various temperatures. The basic detector consists of meandering inductor and interdigitated capacitor fingers. The inductor volume is varied from 2 to 153 {\mu}m^{3} by changing the inductor width and length to maintain a constant inductance. We started with measuring the power spectrum density (PSD) of the detectors frequency noise which is a function of GR noise and we clearly observed the spectrum roll off at 10 kHz which corresponds to the quasiparticle lifetime. Using data from a temperature sweep of the resonator frequency we convert the frequency fluctuation to quasiparticle fluctuation and observe its strong dependence on detector volume: detectors with smaller volume display less quasiparticle noise amplitude. Meanwhile we observe a saturated quasiparticle density at low temperature from all detectors as the quasiparticle life time {\tau}qp approaches a constant value at low temperature.

astro-ph.IM

Noise Optimization for MKIDs with Different Design Geometries and Material Selections

The separation and optimization of noise components is critical to microwave-kinetic inductance detector (MKID) development. We analyze the effect of several changes to the lumped-element inductor and interdigitated capacitor geometry on the noise performance of a series of MKIDs intended for millimeter-wavelength experiments. We extract the contributions from two-level system noise in the dielectric layer, the generation-recombination noise intrinsic to the superconducting thin-film, and system white noise from each detector noise power spectrum and characterize how these noise components depend on detector geometry, material, and measurement conditions such as driving power and temperature. We observe a reduction in the amplitude of two-level system noise with both an elevated sample temperature and an increased gap between the fingers within the interdigitated capacitors for both aluminum and niobium detectors. We also verify the expected reduction of the generation-recombination noise and associated quasiparticle lifetime with reduced inductor volume. This study also iterates over different materials, including aluminum, niobium, and aluminum manganese, and compares the results with an underlying physical model.

astro-ph.IM

Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping

Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = 300 on-chip superconducting filter-bank spectrometer covering the 120--180 GHz band optimized for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.

astro-ph.IM

Low-loss Si-based Dielectrics for High Frequency Components of Superconducting Detectors

Silicon-based dielectric is crucial for many superconducting devices, including high-frequency transmission lines, filters, and resonators. Defects and contaminants in the amorphous dielectric and at the interfaces between the dielectric and metal layers can cause microwave losses and degrade device performance. Optimization of the dielectric fabrication, device structure, and surface morphology can help mitigate this problem. We present the fabrication of silicon oxide and nitride thin film dielectrics. We then characterized them using Scanning Electron Microscopy, Atomic Force Microscopy, and spectrophotometry techniques. The samples were synthesized using various deposition methods, including Plasma-Enhanced Chemical Vapor Deposition and magnetron sputtering. The films morphology and structure were modified by adjusting the deposition pressure and gas flow. The resulting films were used in superconducting resonant systems consisting of planar inductors and capacitors. Measurements of the resonator properties, including their quality factor, were performed.

astro-ph.IM

Measurement of Dielectric Loss in Silicon Nitride at Centimeter and Millimeter Wavelengths

This work presents a suite of measurement techniques for characterizing the dielectric loss tangent across a wide frequency range from $\sim$1 GHz to 150 GHz using the same test chip. In the first method, we fit data from a microwave resonator at different temperatures to a model that captures the two-level system (TLS) response to extract and characterize both the real and imaginary components of the dielectric loss. The inverse of the internal quality factor is a second measure of the overall loss of the resonator, where TLS loss through the dielectric material is typically the dominant source. The third technique is a differential optical measurement at 150 GHz. The same antenna feeds two microstrip lines with different lengths that terminate in two microwave kinetic inductance detectors (MKIDs). The difference in the detector response is used to estimate the loss per unit length of the microstrip line. Our results suggest a larger loss for SiN$_x$ at 150 GHz of ${\mathrm{\tan \delta\sim 4\times10^{-3}}}$ compared to ${\mathrm{2.0\times10^{-3}}}$ and ${\mathrm{\gtrsim 1\times10^{-3}}}$ measured at $\sim$1 GHz using the other two methods. {These measurement techniques can be applied to other dielectrics by adjusting the microstrip lengths to provide enough optical efficiency contrast and other mm/sub-mm frequency ranges by tuning the antenna and feedhorn accordingly.

astro-ph.IM

Simultaneous Millimeter-wave, Gamma-ray, and Optical Monitoring of the Blazar PKS 2326-502 During a Flaring State

Including millimeter-wave (mm-wave) data in multi-wavelength studies of the variability of active galactic nuclei (AGN) can provide insights into AGN physics that are not easily accessible at other wavelengths. We demonstrate in this work the potential of cosmic microwave background (CMB) telescopes to provide long-term, high-cadence mm-wave AGN monitoring over large fractions of sky. We report on a pilot study using data from the SPTpol instrument on the South Pole Telescope (SPT), which was designed to observe the CMB at arcminute and larger angular scales. Between 2013 and 2016, SPTpol was used primarily to observe a single 500 deg^2 field, covering the entire field several times per day with detectors sensitive to radiation in bands centered at 95 and 150 GHz. We use SPT 150 GHz observations to create AGN light curves, and we compare these mm-wave light curves to those at other wavelengths, in particular gamma-ray and optical. In this Letter, we focus on a single source, PKS 2326-502, which has extensive, day-timescale monitoring data in gamma-ray, optical, and now mm-wave between 2013 and 2016. We find PKS 2326-502 to be in a flaring state in the first two years of this monitoring, and we present a search for evidence of correlated variability between mm-wave, optical R band, and gamma-ray observations. This pilot study is paving the way for AGN monitoring with current and upcoming CMB experiments such as SPT-3G, Simons Observatory, and CMB-S4, including multi-wavelength studies with facilities such as VRO-LSST.

astro-ph.HE

A Measurement of the CMB Temperature Power Spectrum and Constraints on Cosmology from the SPT-3G 2018 TT/TE/EE Data Set

We present a sample-variance-limited measurement of the temperature power spectrum ($TT$) of the cosmic microwave background (CMB) using observations of a $\sim\! 1500 \,\mathrm{deg}^2$ field made by SPT-3G in 2018. We report multifrequency power spectrum measurements at 95, 150, and 220GHz covering the angular multipole range $750 \leq \ell < 3000$. We combine this $TT$ measurement with the published polarization power spectrum measurements from the 2018 observing season and update their associated covariance matrix to complete the SPT-3G 2018 $TT/TE/EE$ data set. This is the first analysis to present cosmological constraints from SPT $TT$, $TE$, and $EE$ power spectrum measurements jointly. We blind the cosmological results and subject the data set to a series of consistency tests at the power spectrum and parameter level. We find excellent agreement between frequencies and spectrum types and our results are robust to the modeling of astrophysical foregrounds. We report results for $\Lambda$CDM and a series of extensions, drawing on the following parameters: the amplitude of the gravitational lensing effect on primary power spectra $A_\mathrm{L}$, the effective number of neutrino species $N_{\mathrm{eff}}$, the primordial helium abundance $Y_{\mathrm{P}}$, and the baryon clumping factor due to primordial magnetic fields $b$. We find that the SPT-3G 2018 $T/TE/EE$ data are well fit by $\Lambda$CDM with a probability-to-exceed of $15\%$. For $\Lambda$CDM, we constrain the expansion rate today to $H_0 = 68.3 \pm 1.5\,\mathrm{km\,s^{-1}\,Mpc^{-1}}$ and the combined structure growth parameter to $S_8 = 0.797 \pm 0.042$. The SPT-based results are effectively independent of Planck, and the cosmological parameter constraints from either data set are within $<1\,\sigma$ of each other. (abridged)

astro-ph.CO

Large area photon calorimeter with Ir-Pt bilayer transition-edge sensor for the CUPID experiment

CUPID is a next-generation neutrinoless double-beta decay experiment that will require cryogenic light detectors to improve background suppression, via the simultaneous readout of heat and light channels from its scintillating crystals. In this work we showcase light detectors based on a novel Ir-Pt bilayer transition edge sensor. We have performed a systematic study to improve the thermal coupling between the photon absorber and the sensor, and thereby its responsivity. Our first devices meet CUPID's baseline noise requirement of <100~eV rms. Our detectors have risetimes of $\sim$180 $\mu$s and measured timing jitter of <20 $\mu$s for the expected signal-to-noise at the Q-value of the decay, which achieves the CUPID's criterion of rejecting two-neutrino double-beta decay pileup events. The current work will inform the fabrication of future devices, culminating in the final TES design and a scaleable readout scheme for CUPID.

physics.ins-det

Conceptual Design of the Modular Detector and Readout System for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over a wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4's science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 square meters of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing.

astro-ph.IM