SearcharxivSearch

arXiv subjects

Valerio Pettinacci

Publications and source records attributed to Valerio Pettinacci.

4 recordsLinked to original sources

A Cryogenic Muon Tagging System Based on Kinetic Inductance Detectors for Superconducting Quantum Processors

Ionizing radiation has emerged as a potential limiting factor for superconducting quantum processors, inducing quasiparticle bursts and correlated errors that challenge fault-tolerant operation. Atmospheric muons are particularly problematic due to their high energy and penetration power, making passive shielding ineffective. Therefore, monitoring the real-time muon flux is crucial to guide the development of alternative error-correction or mitigation strategies. We present the design, simulation, and first operation of a cryogenic muon-tagging system based on Kinetic Inductance Detectors (KIDs), developed as a stand-alone cryogenic particle-tagging module for superconducting quantum processors. The system consists of two KIDs arranged in a vertical stack and operated at $\sim$20 mK. Monte Carlo simulations based on Geant4 guided the prototype design and provided reference expectations for muon-tagging efficiency and accidental coincidences due to ambient $\gamma$-rays. We observed a muon-induced coincidence rate among the top and bottom detectors of (192 $\pm$ 9)$\times10^{-3}$ events/s, in excellent agreement with the Monte Carlo prediction. The prototype achieves a muon-tagging efficiency of about 90% with negligible dead time. These results demonstrate the feasibility of operating a muon-tagging system at millikelvin temperatures and represent a key step toward the integration of cryogenic veto systems with multi-qubit chips to mitigate muon-induced errors.

quant-ph

Evaluating radiation impact on transmon qubits in above and underground facilities

Superconducting qubits can be sensitive to abrupt energy deposits caused by cosmic rays and ambient radioactivity. While previous studies have explored correlated effects in time and space due to cosmic ray interactions, we present the first direct comparison of a transmon qubit's performance measured at two distinct sites: the above-ground SQMS facility (Fermilab, US) and the deep-underground Gran Sasso Laboratory (Italy). Despite the stark difference in radiation levels, we observe a similar average qubit relaxation time of approximately 80 microseconds at both locations. To further investigate potential radiation-induced events, we employ a fast decay detection protocol, comparing the relative rates of triggered events between the two environments. Although intrinsic noise remains the dominant source of single errors in superconducting qubits, our analysis revealed a significant excess of radiation-induced events for high-coherence transmon qubits operated above-ground. Finally, using $\gamma$-ray sources with increasing activity levels, we evaluate the qubit response in a controlled low-background environment.

quant-ph

The Search for $μ^+\to e^+ γ$ with 10$^{-14}$ Sensitivity: the Upgrade of the MEG Experiment

The MEG experiment took data at the Paul Scherrer Institute in the years 2009--2013 to test the violation of the lepton flavour conservation law, which originates from an accidental symmetry that the Standard Model of elementary particle physics has, and published the most stringent limit on the charged lepton flavour violating decay $μ^+ \rightarrow {\rm e}^+ γ$: BR($μ^+ \rightarrow {\rm e}^+ γ$) $<4.2 \times 10^{-13}$ at 90% confidence level. The MEG detector has been upgraded in order to reach a sensitivity of $6\times10^{-14}$. The basic principle of MEG II is to achieve the highest possible sensitivity using the full muon beam intensity at the Paul Scherrer Institute ($7\times10^{7}$ muons/s) with an upgraded detector. The main improvements are better rate capability of all sub-detectors and improved resolutions while keeping the same detector concept. In this paper, we present the current status of the preparation, integration and commissioning of the MEG II detector in the recent engineering runs.

hep-ex

Final results of CALDER: Kinetic inductance light detectors to search for rare events

The next generation of bolometric experiments searching for rave events, in particular for the neutrino-less double beta decay, needs fast, high-sensitivity and easy-to-scale cryogenic light detectors. The CALDER project (2014-2020) developed a new technology for light detection at cryogenic temperature. In this paper we describe the achievements and the final prototype of this project, consisting of a $5\times5$ cm$^2$, 650 $μ$m thick silicon substrate coupled to a single kinetic inductance detector made of a three-layer aluminum-titanium-aluminum. The baseline energy resolution is 34$\pm$1(stat)$\pm$2(syst) eV RMS and the response time is 120 $μ$s. These features, along with the natural multiplexing capability of kinetic inductance detectors, meet the requirements of future large-scale experiments.

physics.ins-det