Searcharxiv⌕ Search

arXiv subjects

Valliappan Muthukaruppan

Publications and source records attributed to Valliappan Muthukaruppan.

8 recordsLinked to original sources

Predicting Estimated Times of Restoration for Electrical Outages Using Longitudinal Tabular Transformers

Utilities publish Estimated Times of Restoration (ETRs) for customer-facing storm outages, and their accuracy governs whether customers can make sound decisions about food, medical equipment, and relocation. Prior work treats ETR as static tabular regression in which each outage contributes one record, discarding the fact that every development of an outage, from crew assignment through dispatch, suspension, damage assessment and partial restoration, is recorded as a revision. We reformulate ETR prediction as longitudinal tabular regression and introduce a Longitudinal Tabular Transformer (LTT), an axial-attention model that consumes the revisions preceding a prediction and issues a refined estimate at every one. On 242{,}928 storm-attributed outages from a cohort of 526{,}468 filtered events and 10.0 million revisions at six operating companies, LTT reduces customer-weighted asymmetric error at all six, by a median of 36.9\,\% against the estimates the utilities published during the same storms and 11.3\,\% against the strongest learned baseline at each. It is the only method improving on the incumbent's satisfaction impact at all six companies while also reducing root mean squared error at all six. Stratification by revision index shows that LTT error is largest at the first revision, where no history is available, and falls monotonically as revisions accumulate.

cs.LG↗

Multi-Feeder Restoration using Multi-Microgrid Formation and Management

This papers highlights the benefit of coordinating resources on mulitple active distribution feeders during severe long duration outages through multi-microgrid formation. A graph-theory based multi-microgrid formation algorithm is developed which is agnostic of the underlying energy management scheme of the microgrids and solved in a rolling horizon fashion. The algorithm is then enhanced to handle multiple feeders where formation of long laterals needs to be avoided due to potential voltage control issues in distribution systems. The algorithm is evaluated on a synthetic two feeder system derived from interconnecting two IEEE 123 node system. The results indicate increased service to loads in the system and better utilization of renewable resources.

eess.SY↗

A Novel Feeder-level Microgrid Unit Commitment Algorithm Considering Cold-load Pickup, Phase Balancing, and Reconfiguration

This paper presents a novel 2-stage microgrid unit commitment (Microgrid-UC) algorithm considering cold-load pickup (CLPU) effects, three-phase load balancing requirements, and feasible reconfiguration options. Microgrid-UC schedules the operation of switches, generators, battery energy storage systems, and demand response resources to supply 3-phase unbalanced loads in an islanded microgrid for multiple days. A performance-based CLPU model is developed to estimate additional energy needs of CLPU so that CLPU can be formulated into the traditional 2-stage UC scheduling process. A per-phase demand response budget term is added to the 1st stage UC objective function to meet 3-phase load unbalance limits. To reduce computational complexity in the 1st stage UC, we replace the spanning tree method with a feasible reconfiguration topology list method. The proposed algorithm is developed on a modified IEEE 123-bus system and tested on the real-time simulation testbed using actual load and PV data. Simulation results show that Microgrid-UC successfully accounts for CLPU, phase imbalance, and feeder reconfiguration requirements.

eess.SY↗

A Supervisory Volt/VAR Control Scheme for Coordinating Voltage Regulators with Smart Inverters on a Distribution System

This paper focuses on the effective use of smart inverters for Volt/Var control (VVC) on a distribution system. New smart inverters offer Var support capability but for their effective use they need to be coordinated with existing Volt/Var schemes. A new VVC scheme is proposed to facilitate such coordination. The proposed scheme decomposes the problem into two levels. The first level uses Load Tap Changer (LTC) and Voltage Regulators (VRs) and coordinates their control with smart inverters to adjust the voltage level on the circuit to keep the voltages along the circuit within the desired range. The second level determines Var support needed from smart inverters to minimize the overall power loss in the circuit. The results of the supervisory control are sent to the devices which have their local controllers. To avoid frequent dispatch, smart inverters are supervised by shifting their Volt/Var characteristics as needed. This allows for the smart inverters to operate close to their optimal control while meeting the limited communication requirements on a distribution system. A case study using the IEEE 34 bus system shows the effectiveness of this supervisory control scheme compared to traditional volt/var schemes.

eess.SY↗

Feeder Microgrid Management on an Active Distribution System during a Severe Outage

Forming a microgrid on a distribution system with large scale outage after a severe weather event is emerging as a viable solution to improve resiliency at the distribution level. This option becomes more attractive when the distribution system has high levels of distributed PV. The management of such feeder-level microgrid has however many challenges, such as limited resources that can be deployed on the feeder quickly, and the limited real-time monitoring and control on the distribution system. Effective use of the distributed PV is also challenging as they are not monitored and controlled. To handle these challenges, the paper proposes a 2-stage hierarchical energy management scheme to securely operate these feeder level micorgrids. The first stage of the scheme solves a sequential rolling optimization problem to optimally schedule the main resources (such as a mobile diesel generator and battery storage unit). The second stage adopts a dispatching scheme for the main resources to adjust the stage-1 set-points closer to real- time. The proposed scheme has unique features to assure that the scheme is robust under highly varying operating conditions with limited system observability: (i) an innovative PV forecast error adjustment and a dynamic reserve adjustment scheme to handle the extreme uncertainty on PV power output, and (ii) an intelligent fuel management scheme to assure that the resources are utilized optimally over the multiple days of the restoration period. The proposed algorithm is tested on sample system with real-time data. The results show that the proposed scheme performs well in maximizing service to loads by effective use of all the resources and by properly taking into account the challenging operating conditions.

eess.SY↗

SA-HMTS: A Secure and Adaptive Hierarchical Multi-timescale Framework for Resilient Load Restoration Using A Community Microgrid

Distribution system integrated community microgrids (CMGs) can partake in restoring loads during extended duration outages. At such times, the CMG is challenged with limited resource availability, absence of robust grid support, and heightened demand-supply uncertainty. This paper proposes a secure and adaptive three-stage hierarchical multi-timescale framework for scheduling and real-time (RT) dispatch of CMGs with hybrid PV systems to address these challenges. The framework enables the CMG to dynamically expand its boundary to support the neighboring grid sections and is adaptive to the changing forecast error impacts. The first stage solves a stochastic extended duration scheduling (EDS) problem to obtain referral plans for optimal resource rationing. The intermediate near-real-time (NRT) scheduling stage updates the EDS schedule closer to the dispatch time using newly obtained forecasts, followed by the RT dispatch stage. To make the dispatch decisions more secure and robust against forecast errors, a novel concept called delayed recourse is proposed. The methodology is evaluated via numerical simulations on a modified IEEE 123-bus system and validated using OpenDSS/hardware-in-loop simulations. The results show superior performance in maximizing load supply and continuous secure CMG operation under numerous operating scenarios.

eess.SY↗

Hierarchical Multi-timescale Framework For Operation of Dynamic Community Microgrid

Distribution system integrated community microgrids (CMGs) can restore loads during extended outages. The CMG is challenged with limited resource availability, absence of a robust grid-support, and demand-supply uncertainty. To address these challenges, this paper proposes a three-stage hierarchical multi-timescale framework for scheduling and real-time (RT) dispatch of CMGs. The CMG's ability to dynamically expand its boundary to support the neighboring grid sections is also considered. The first stage solves a stochastic day-ahead (DA) scheduling problem to obtain referral plans for optimal resource rationing. The intermediate near real-time scheduling stage updates the DA schedule closer to the dispatch time, followed by the RT dispatch stage. The proposed methodology is validated via numerical simulations on a modified IEEE 123-bus system, which shows superior performance in terms of RT load supplied under different forecast error cases, outage duration scenarios, and against the traditionally used two-stage approach.

eess.SY↗

A Load Switching Group based Feeder-level Microgrid Energy Management Algorithm for Service Restoration in Power Distribution System

This paper presents a load switching group based energy management system (LSG-EMS) for operating microgrids on a distribution feeder powered by one or multiple grid-forming distributed energy resources. Loads on a distribution feeder are divided into load switching groups that can be remotely switched on and off. The LSG-EMS algorithm, formulated as a mixed-integer linear programming (MILP) problem, has an objective function of maximizing the served loads while minimizing the total number of switching actions. A new set of topology constraints are developed for allowing multiple microgrids to be formed on the feeder and selecting the optimal supply path. Customer comfort is accounted for by maximizing the supply duration in the customer preferred service period and enforcing a minimum service duration. The proposed method is demonstrated on a modified IEEE 33-bus system using actual customer data. Simulation results show that the LSG-EMS successfully coordinates multiple grid-forming sources by selecting an optimal supply topology that maximizes the supply period of both the critical and noncritical loads while minimizing customer service interruptions in the service restoration process.

eess.SY↗