SearcharxivSearch

arXiv subjects

Vasileios Gkinis

Publications and source records attributed to Vasileios Gkinis.

4 recordsLinked to original sources

Molecular diffusion of stable water isotopes in polar firn as a proxy for past temperatures

Polar precipitation archived in ice caps contains information on past temperature conditions. Such information can be retrieved by measuring the water isotopic signals of $δ^{18}\mathrm{O}$ and $δ\mathrm{D}$ in ice cores. These signals have been attenuated during densification due to molecular diffusion in the firn column, where the magnitude of the diffusion is isotopologoue specific and temperature dependent. By utilizing the differential diffusion signal, dual isotope measurements of $δ^{18}\mathrm{O}$ and $δ\mathrm{D}$ enable multiple temperature reconstruction techniques. This study assesses how well six different methods can be used to reconstruct past surface temperatures from the diffusion-based temperature proxies. Two of the methods are based on the single diffusion lengths of $δ^{18}\mathrm{O}$ and $δ\mathrm{D}$, three of the methods employ the differential diffusion signal, while the last uses the ratio between the single diffusion lengths. All techniques are tested on synthetic data in order to evaluate their accuracy and precision. We perform a benchmark test to thirteen high resolution Holocene data sets from Greenland and Antarctica, which represent a broad range of mean annual surface temperatures and accumulation rates. Based on the benchmark test, we comment on the accuracy and precision of the methods. Both the benchmark test and the synthetic data test demonstrate that the most precise reconstructions are obtained when using the single isotope diffusion lengths, with precisions of approximately $1.0\,^\mathrm{o}\mathrm{C}$. In the benchmark test, the single isotope diffusion lengths are also found to reconstruct consistent temperatures with a root-mean-square-deviation of $0.7\,^\mathrm{o}\mathrm{C}$.

physics.geo-ph

Water isotope diffusion rates from the NorthGRIP ice core for the last 16,000 years - glaciological and paleoclimatic implications

A high resolution (0.05 m) water isotopic record ($δ^{18}\mathrm{O}$) is available from the NorthGRIP ice core. In this study we look into the water isotope diffusion history as estimated by the spectral characteristics of the $δ^{18}\mathrm{O}$ time series covering the last 16,000 years. The diffusion of water vapor in the porous medium of the firn pack attenuates the initial isotopic signal, predominantly having an impact on the high frequency components of the power spectrum. Higher temperatures induce higher rates of smoothing and thus the signal can be used as a firn paleothermometer. We use a water isotope diffusion model coupled to a steady-state densification model in order to infer the temperature signal from the site, assuming the accumulation and strain rate history as estimated using the GICC05 layer counted chronology and a Dansgaard--Johnsen ice flow model. The temperature reconstruction accurately captures the timing and magnitude of the Bølling--Allerød and Younger Dryas transitions. A Holocene climatic optimum is seen between 7 and 9 ky b2k with an apparent cooling trend thereafter. Our temperature estimate for the Holocene climatic optimum, points to a necessary adjustment of the ice thinning function indicating that the ice flow model overestimates past accumulation rates by about 10\% at 8 ky b2k. Finally, the record presents a climatic variability over the Holocene spanning millennial and centennial scales with a profound cooling occurring at approximately 4000 years b2k. The new reconstruction technique is able to provide past temperature estimates by overcoming the issues apparent in the use of the classical $δ^{18}\mathrm{O}$ slope method. It can in the same time resolve temperature signals at low and high frequencies.

physics.geo-ph

A continuous stream flash evaporator for the calibration of an IR cavity ring down spectrometer for isotopic analysis of water

A new technique for high resolution simultaneous isotopic analysis of $δ^{18}\mathrm{O}$ and $δ\mathrm{D}$ in liquid water is presented. A continuous stream flash evaporator has been designed that is able to vaporise a stream of liquid water in a continuous mode and deliver a stable and finely controlled water vapour sample to a commercially available Infra Red Cavity Ring Down Spectrometer. Injection of sub $μl$ amounts of the liquid water is achieved by pumping liquid water sample through a fused silica capillary and instantaneously vaporising it with a 100% efficiency in a home made oven at a temperature of $170 ^{o}$C. The system's simplicity, low power consumption and low dead volume together with the possibility for automated unattended operation, provides a solution for the calibration of laser instruments performing isotopic analysis of water vapour. Our work is mainly driven by the possibility to perform high resolution on line water isotopic analysis on Continuous Flow Analysis systems typically used to analyze the chemical composition of ice cores drilled in polar regions. In the following we describe the system's precision and stability, sensitivity to varying levels of sample size and we assess the observed memory effects. A test run with standard waters of different isotopic composition is presented, demonstrating the ability to calibrate the spectrometer's measurements on a VSMOW scale with a relatively simple and fast procedure.

physics.ins-det